Top Page > Component List > 20UPGM23210493 > QC Result / MODULE/FINAL_WARM / IV_MEASURE


20UPGM23210493
Outer-Quad-Module/ITkPix_v2
  ITkPD Component Page Jump to ITkPD component page

Component Information

Item Value
Serial Number 20UPGM23210493
Production DB Component ID a3408c805ec2e2d4c28203e1b408c43a
LocalDB Component ID 6710b781eff9780043ad2f66
Component Type module
Super-Component No match.
Sub-Components •  20UPGB43200013   Bare Module
•  20UPGPQ2210493   PCB
•  20UPGFC0132758   FE Chip
•  20UPGFC0132790   FE Chip
•  20UPGFC0132807   FE Chip
•  20UPGFC0132743   FE Chip
Flags

Properties

Item Data Type Value
PCB-Bare Orientation isNormal boolean True
FE chip version codeTable 3
Wirebond protection roof presence boolean True
Alternative ID string PPPV2_09
Rank codeTable None

Comments


Test: IV_MEASURE QC Passed

(Stage: MODULE/FINAL_WARM)


Basic View Only: custom view for this TestRun is not prepared.

Metadata

Key Data
QC Passed True
Date 2025-03-12 04:11:23 PDT(-0700)
component ObjectId 6710b781eff9780043ad2f66
Stage MODULE/FINAL_WARM
Test Type IV_MEASURE
Institute ObjectId
User Name FrancescoCrescioli
ObjectId of this record 67d146530548d7bb612a73b3
ObjectId of RAW record 67d146500548d7bb612a73ac

Results

Key Data
ANALYSIS_VERSION mqat v2.3.1rc4
HUM 0
MEASUREMENT_DATE 2025-03-12T08:24:55.000+00:00
MEASUREMENT_DURATION 600
TEMP 17.53
BREAKDOWN_REDUCTION 0
BREAKDOWN_VOLTAGE -999
IV_ARRAY {'voltage': [4.955476102374849, 9.956190517970494, 14.963666779654366, 19.96471441359747, 24.96761885143461, 29.97795232137044, 34.975428989955354, 39.97909527733212, 44.978238605317614, 49.9552381606329, 54.98099971952893, 59.97157142275856, 64.99819147019159, 69.97938065301804, 74.99885777064732, 79.99052429199219, 84.99819147019159, 89.99676368350075, 94.96747807094027, 100.00743066696892, 104.98728797549292, 109.9970968337286, 114.97381083170572, 119.99109286353702, 124.97642662411644, 129.99747285388764, 134.96028863816034, 139.98238263811385, 144.9737592424665, 149.88437834240142, 154.9644746326265, 159.87918890090216, 164.95700073242188, 169.87061854771204, 174.94390433175224, 179.96271405901228, 184.92909095400856, 189.95275951567152, 194.9277605329241, 199.9509531656901], 'current': [0.1065238082692737, 0.12223809602714722, 0.13366666649069106, 0.14157143093290786, 0.1484285692373912, 0.15295237799485525, 0.15519047493026372, 0.1578571462915057, 0.15995238082749502, 0.16514285618350621, 0.1640000002724784, 0.1671428559791474, 0.16752380558422633, 0.1704285684086028, 0.16857142675490608, 0.17266666747274856, 0.17190476116679965, 0.17223809588523137, 0.1770952336844944, 0.1756190451837722, 0.17919047602585386, 0.17880952500161676, 0.18328571958201278, 0.1803333376135145, 0.18357143018926894, 0.18209523955980933, 0.18385713795820877, 0.18609523347445897, 0.1834285720473244, 0.1885238112438293, 0.18909524097329095, 0.19052381316820782, 0.1896666678644362, 0.19376190290564585, 0.19200000237850923, 0.19042856920333134, 0.1943809531983875, 0.1941428588969367, 0.194761906351362, 0.1932380972873597], 'sigma current': [0.002217229332446361, 0.0010647940052669151, 0.002748737405225783, 0.0017612615475101378, 0.006904598948400026, 0.0020348479922262476, 0.0033752465470830574, 0.0017261472853257632, 0.0013964624696185634, 0.013075917669551905, 0.001603564506194604, 0.008876323114208442, 0.001990911126771651, 0.010531455163862077, 0.0021285249931636556, 0.006692806633198102, 0.002348346648460025, 0.002158144608341253, 0.012316866766754007, 0.0016754879819162458, 0.011219112866176177, 0.0014998088813730941, 0.010717776844716888, 0.0007126927794255129, 0.012292357229440271, 0.0027238754779125036, 0.01080249379858704, 0.017781488596707733, 0.006366363460988747, 0.01736065385769259, 0.008618388322930137, 0.01738258359527481, 0.008230795903772242, 0.016256589124473163, 0.008933617457692935, 0.001293626013878323, 0.009291451113028681, 0.001355258243198905, 0.009645649714873512, 0.002244671223358635], 'temperature': [17.65, 17.56, 17.59, 17.67, 17.62, 17.59, 17.59, 17.61, 17.62, 17.59, 17.63, 17.53, 17.58, 17.6, 17.51, 17.56, 17.54, 17.52, 17.56, 17.49, 17.54, 17.47, 17.51, 17.53, 17.46, 17.45, 17.46, 17.44, 17.47, 17.42, 17.46, 17.46, 17.46, 17.55, 17.45, 17.49, 17.53, 17.6, 17.46, 17.35], 'humidity': []}
LEAK_CURRENT 0.22093111135954163
LEAK_INCREASE_FACTOR 1.11
LEAK_PER_AREA 0.01
MAXIMUM_VOLTAGE 199.9509531656901
NO_BREAKDOWN_VOLTAGE_OBSERVED True

Attachments

Filename Contents
output.log Download
20UPGM23210493_plot.png
20UPGM23210493_summary.png

RAW Results Record

Download RAW
_id67d146500548d7bb612a73ac
raw
serialNumbertestTypesubtestTyperesultsstagecomponentdbVersionaddresssys
20UPGM23210493IV_MEASURE
Measurements
voltage
XTrue
UnitV
Values
  • 4.955476102374849
  • 9.956190517970494
  • 14.963666779654366
  • 19.96471441359747
  • 24.96761885143461
  • 29.97795232137044
  • 34.975428989955354
  • 39.97909527733212
  • 44.978238605317614
  • 49.9552381606329
  • 54.98099971952893
  • 59.97157142275856
  • 64.99819147019159
  • 69.97938065301804
  • 74.99885777064732
  • 79.99052429199219
  • 84.99819147019159
  • 89.99676368350075
  • 94.96747807094027
  • 100.00743066696892
  • 104.98728797549292
  • 109.9970968337286
  • 114.97381083170572
  • 119.99109286353702
  • 124.97642662411644
  • 129.99747285388764
  • 134.96028863816034
  • 139.98238263811385
  • 144.9737592424665
  • 149.88437834240142
  • 154.9644746326265
  • 159.87918890090216
  • 164.95700073242188
  • 169.87061854771204
  • 174.94390433175224
  • 179.96271405901228
  • 184.92909095400856
  • 189.95275951567152
  • 194.9277605329241
  • 199.9509531656901
current
XFalse
UnitA
Values
  • -1.0652380826927369e-07
  • -1.222380960271472e-07
  • -1.3366666649069106e-07
  • -1.4157143093290786e-07
  • -1.4842856923739118e-07
  • -1.5295237799485525e-07
  • -1.551904749302637e-07
  • -1.578571462915057e-07
  • -1.5995238082749502e-07
  • -1.651428561835062e-07
  • -1.640000002724784e-07
  • -1.671428559791474e-07
  • -1.6752380558422633e-07
  • -1.7042856840860278e-07
  • -1.6857142675490606e-07
  • -1.7266666747274855e-07
  • -1.7190476116679964e-07
  • -1.7223809588523136e-07
  • -1.770952336844944e-07
  • -1.7561904518377217e-07
  • -1.7919047602585387e-07
  • -1.7880952500161674e-07
  • -1.8328571958201278e-07
  • -1.803333376135145e-07
  • -1.8357143018926892e-07
  • -1.8209523955980933e-07
  • -1.8385713795820875e-07
  • -1.8609523347445897e-07
  • -1.834285720473244e-07
  • -1.885238112438293e-07
  • -1.8909524097329095e-07
  • -1.905238131682078e-07
  • -1.896666678644362e-07
  • -1.9376190290564585e-07
  • -1.9200000237850923e-07
  • -1.9042856920333133e-07
  • -1.943809531983875e-07
  • -1.941428588969367e-07
  • -1.94761906351362e-07
  • -1.932380972873597e-07
sigma current
XFalse
UnitA
Values
  • 2.217229332446361e-09
  • 1.064794005266915e-09
  • 2.7487374052257828e-09
  • 1.7612615475101376e-09
  • 6.904598948400025e-09
  • 2.0348479922262476e-09
  • 3.3752465470830572e-09
  • 1.726147285325763e-09
  • 1.3964624696185634e-09
  • 1.3075917669551905e-08
  • 1.603564506194604e-09
  • 8.876323114208442e-09
  • 1.990911126771651e-09
  • 1.0531455163862077e-08
  • 2.1285249931636553e-09
  • 6.692806633198102e-09
  • 2.348346648460025e-09
  • 2.158144608341253e-09
  • 1.2316866766754006e-08
  • 1.6754879819162459e-09
  • 1.1219112866176177e-08
  • 1.4998088813730942e-09
  • 1.0717776844716888e-08
  • 7.126927794255129e-10
  • 1.2292357229440271e-08
  • 2.7238754779125035e-09
  • 1.080249379858704e-08
  • 1.778148859670773e-08
  • 6.366363460988747e-09
  • 1.736065385769259e-08
  • 8.618388322930136e-09
  • 1.7382583595274807e-08
  • 8.230795903772242e-09
  • 1.6256589124473162e-08
  • 8.933617457692936e-09
  • 1.293626013878323e-09
  • 9.29145111302868e-09
  • 1.355258243198905e-09
  • 9.645649714873511e-09
  • 2.244671223358635e-09
temperature
XFalse
UnitC
Values
  • 17.65
  • 17.56
  • 17.59
  • 17.67
  • 17.62
  • 17.59
  • 17.59
  • 17.61
  • 17.62
  • 17.59
  • 17.63
  • 17.53
  • 17.58
  • 17.6
  • 17.51
  • 17.56
  • 17.54
  • 17.52
  • 17.56
  • 17.49
  • 17.54
  • 17.47
  • 17.51
  • 17.53
  • 17.46
  • 17.45
  • 17.46
  • 17.44
  • 17.47
  • 17.42
  • 17.46
  • 17.46
  • 17.46
  • 17.55
  • 17.45
  • 17.49
  • 17.53
  • 17.6
  • 17.46
  • 17.35
humidity
XFalse
Unit%
Values
property
IV_MEASURE_MEASUREMENT_VERSIONconvertIV_mqt
comment
metadata
ModuleSN20UPGM23210493
InstitutionLPNHE
TimeStart1741767895
TimeEnd1741768495
MODULE/FINAL_WARM6710b781eff9780043ad2f661.0164657cef8d79bac1f3f00584
mts2025-03-12 08:31:12.118000
cts2025-03-12 08:31:12.118000
rev0
rawHash67a47cb21508178af6b7dbbe5bd888e1
stageMODULE/FINAL_WARM

ProductionDB Record

id67d16bda5ae416616e4f40fb
stateready
stateTs2025-03-12T11:11:22.775Z
stateUserIdentity9086-39-1
date2025-03-12T08:31:00.000Z
testType
id6418494b21d98a00388285bd
codeIV_MEASURE
nameIV measurement
stateactive
institution
id5d42fb891fd678000a409866
codeLPNHE
nameLaboratoire de Physique Nucléaire et de Hautes Energies
user
id5e98594f8bc0cb000ba8d3a8
userIdentity9086-39-1
firstNameFrancesco
middleName
lastNameCrescioli
runNumber67d146530548d7bb612a73b3
passedTrue
problemsFalse
properties
codenamedataTypevalueTyperequiredvaluerangeMinrangeMax
ANALYSIS_VERSIONAnalysis VersionstringsingleFalse2.3.1rc4NoneNone
HUMHumidity (%)floatsingleTrue0NoneNone
MEASUREMENT_DATEDate measurement performeddatetimeNoneFalse2025-03-12T08:24:55.000+00:00NoneNone
MEASUREMENT_DURATIONMeasurement durationintegerNoneFalse600NoneNone
TEMPTemperature (°C)floatsingleTrue17.53NoneNone
results
codenamedataTypevalueTypearrayDimensionsadditionalrangeMinrangeMaxvalueassociateChild
BREAKDOWN_REDUCTIONBreakdown Voltage Reduction (V)floatsingleNoneFalseNoneNone0None
BREAKDOWN_VOLTAGEBreakdown voltage (V) (-999V if no breakdown measured)floatsingleNoneFalseNoneNone-999None
IV_ARRAYIV dataobjectsingleNoneFalseNoneNone
voltage
  • 4.955476102374849
  • 9.956190517970494
  • 14.963666779654366
  • 19.96471441359747
  • 24.96761885143461
  • 29.97795232137044
  • 34.975428989955354
  • 39.97909527733212
  • 44.978238605317614
  • 49.9552381606329
  • 54.98099971952893
  • 59.97157142275856
  • 64.99819147019159
  • 69.97938065301804
  • 74.99885777064732
  • 79.99052429199219
  • 84.99819147019159
  • 89.99676368350075
  • 94.96747807094027
  • 100.00743066696892
  • 104.98728797549292
  • 109.9970968337286
  • 114.97381083170572
  • 119.99109286353702
  • 124.97642662411644
  • 129.99747285388764
  • 134.96028863816034
  • 139.98238263811385
  • 144.9737592424665
  • 149.88437834240142
  • 154.9644746326265
  • 159.87918890090216
  • 164.95700073242188
  • 169.87061854771204
  • 174.94390433175224
  • 179.96271405901228
  • 184.92909095400856
  • 189.95275951567152
  • 194.9277605329241
  • 199.9509531656901
current
  • 0.1065238082692737
  • 0.12223809602714722
  • 0.13366666649069106
  • 0.14157143093290786
  • 0.1484285692373912
  • 0.15295237799485525
  • 0.15519047493026372
  • 0.1578571462915057
  • 0.15995238082749502
  • 0.16514285618350621
  • 0.1640000002724784
  • 0.1671428559791474
  • 0.16752380558422633
  • 0.1704285684086028
  • 0.16857142675490608
  • 0.17266666747274856
  • 0.17190476116679965
  • 0.17223809588523137
  • 0.1770952336844944
  • 0.1756190451837722
  • 0.17919047602585386
  • 0.17880952500161676
  • 0.18328571958201278
  • 0.1803333376135145
  • 0.18357143018926894
  • 0.18209523955980933
  • 0.18385713795820877
  • 0.18609523347445897
  • 0.1834285720473244
  • 0.1885238112438293
  • 0.18909524097329095
  • 0.19052381316820782
  • 0.1896666678644362
  • 0.19376190290564585
  • 0.19200000237850923
  • 0.19042856920333134
  • 0.1943809531983875
  • 0.1941428588969367
  • 0.194761906351362
  • 0.1932380972873597
sigma current
  • 0.002217229332446361
  • 0.0010647940052669151
  • 0.002748737405225783
  • 0.0017612615475101378
  • 0.006904598948400026
  • 0.0020348479922262476
  • 0.0033752465470830574
  • 0.0017261472853257632
  • 0.0013964624696185634
  • 0.013075917669551905
  • 0.001603564506194604
  • 0.008876323114208442
  • 0.001990911126771651
  • 0.010531455163862077
  • 0.0021285249931636556
  • 0.006692806633198102
  • 0.002348346648460025
  • 0.002158144608341253
  • 0.012316866766754007
  • 0.0016754879819162458
  • 0.011219112866176177
  • 0.0014998088813730941
  • 0.010717776844716888
  • 0.0007126927794255129
  • 0.012292357229440271
  • 0.0027238754779125036
  • 0.01080249379858704
  • 0.017781488596707733
  • 0.006366363460988747
  • 0.01736065385769259
  • 0.008618388322930137
  • 0.01738258359527481
  • 0.008230795903772242
  • 0.016256589124473163
  • 0.008933617457692935
  • 0.001293626013878323
  • 0.009291451113028681
  • 0.001355258243198905
  • 0.009645649714873512
  • 0.002244671223358635
temperature
  • 17.65
  • 17.56
  • 17.59
  • 17.67
  • 17.62
  • 17.59
  • 17.59
  • 17.61
  • 17.62
  • 17.59
  • 17.63
  • 17.53
  • 17.58
  • 17.6
  • 17.51
  • 17.56
  • 17.54
  • 17.52
  • 17.56
  • 17.49
  • 17.54
  • 17.47
  • 17.51
  • 17.53
  • 17.46
  • 17.45
  • 17.46
  • 17.44
  • 17.47
  • 17.42
  • 17.46
  • 17.46
  • 17.46
  • 17.55
  • 17.45
  • 17.49
  • 17.53
  • 17.6
  • 17.46
  • 17.35
humidity
None
LEAK_CURRENTLeakage current of sensor (μA) at operation voltagefloatsingleNoneFalseNoneNone0.22093111135954163None
LEAK_INCREASE_FACTORLeakage Current Increase FactorfloatsingleNoneFalseNoneNone1.11None
LEAK_PER_AREALeakage Current per Area (uA/cm^2)floatsingleNoneFalseNoneNone0.01None
MAXIMUM_VOLTAGEMaximum (absolute) measured voltage (V)floatsingleNoneFalseNoneNone199.9509531656901None
NO_BREAKDOWN_VOLTAGE_OBSERVEDNo breakdown voltage observedbooleansingleNoneFalseNoneNoneTrueNone
cts2025-03-12T11:11:22.775Z
sys
cts2025-03-12T11:11:22.775Z
mts2025-03-12T11:11:23.808Z
rev2
defects
commentsNone
attachments
  • codec1e2c4cfa0ddfd8df3e11df0c15a7143
    dateTime2025-03-12T11:11:22.938Z
    titleTestRun_67d16bda5ae416616e4f40fb_Attachment_Pack.zip
    description/home/data/viewer/static/cache/thumbnail/TestRun_67d16bda5ae416616e4f40fb_Attachment_Pack.zip
    contentTypeNone
    typeeos
    urlhttps://eosatlas.cern.ch/eos/atlas/atlascerngroupdisk/det-itk/prod-db/c/1/e/c1e2c4cfa0ddfd8df3e11df0c15a7143?authz=zteos64:MDAwMDAyYmN4nO2QP0vDUBTFaUWFTtWxIFzEwSXJe_mfi4Oz0EVwihle-l7S0DYvJK8O_RDq0m_grp9AcOoszlYUcXGpOAvG4uDg6OgdDpcf514OpzVrthpl-_by6Xqts5qpQcG3m5Nit2FahpCVwdSQfWtPlHlaynHBs2pgcKG02m4UpeQaj42eQQ1xsMM84QrXMjVieZ5GaUK0OCauxuw4IdQLXM8MDu8aYVfm0GUlUA9MEy0bHQImMZ0IxhlHalPXp-EyTgTpF7GIF06KCFTGRa6wlFLpju96FkGbOs5-iJjUgw7VKXX1wNcpiSBnI4HLN8BzhDqswkEZO8CKAqEvK4W_H3I5YlmOP0gqJBKHWlCNeb2BKllPIMg8Fn02THATNmYrafs8-Dh5gDlvPs9P3x6nR4sz_3Vx_L538bLV-e_6j7qGm6vp_fon_wLcUA%3d%3d
    urlCernboxhttps://cernbox.cern.ch/files/spaces/eos/atlas/atlascerngroupdisk/det-itk/prod-db/c/1/e/c1e2c4cfa0ddfd8df3e11df0c15a7143
    filenamec1e2c4cfa0ddfd8df3e11df0c15a7143
    user
    id5e98594f8bc0cb000ba8d3a8
    userIdentity9086-39-1
    firstNameFrancesco
    middleName
    lastNameCrescioli
  • code7bc6935be4c0885efc7a568ae5fdb519
    dateTime2025-03-12T11:11:23.721Z
    titleRAW
    descriptionRAW
    contentTypetext/plain
    typefile
    binaryStoreg02True
    filename20UPGM23210493_MODULE__FINAL_WARM_IV_MEASURE_67d16bda5ae416616e4f40fb_67d146500548d7bb612a73ac.json
    user
    id5e98594f8bc0cb000ba8d3a8
    userIdentity9086-39-1
    firstNameFrancesco
    middleName
    lastNameCrescioli
components
idcodestatestateTsstateUserIdentitydummycompletedcompletedTscompletedUserIdentitytrashedtrashedTstrashedUserIdentityserialNumberalternativeIdentifierprojectsubprojectcomponentTypetypepropertiestestedAtStageinstitution
6710b781eff9780043ad2f66a3408c805ec2e2d4c28203e1b408c43aready2024-10-17T07:06:41.688Z9086-39-1FalseFalseNoneNoneFalseNoneNone20UPGM23210493PPPV2_09
codeP
namePixels
codePG
namePixel general
codeMODULE
nameModule
codeOUTER_SYSTEM_QUAD_MODULE
nameOuter system quad module
  • codeORIENTATION
    namePCB-Bare Orientation isNormal
    dataTypeboolean
    requiredTrue
    defaultFalse
    valueTrue
  • codeFECHIP_VERSION
    nameFE chip version
    dataTypecodeTable
    requiredTrue
    defaultFalse
    valueITkpix_v2
    codeTable
    codevalue
    0RD53A
    1ITkpix_v1
    2ITkpix_v1.1
    3ITkpix_v2
    9No FE chip
  • codeROOF
    nameWirebond protection roof presence
    dataTypeboolean
    requiredFalse
    defaultFalse
    valueTrue
  • codeIREFTRIM_FE1
    nameIREFTRIM_FE1
    valueNone
  • codeIREFTRIM_FE2
    nameIREFTRIM_FE2
    valueNone
  • codeIREFTRIM_FE3
    nameIREFTRIM_FE3
    valueNone
  • codeIREFTRIM_FE4
    nameIREFTRIM_FE4
    valueNone
  • codeALTERNATIVE_IDENTIFIER
    nameAlternative ID
    dataTypestring
    requiredFalse
    defaultTrue
    valuePPPV2_09
codeMODULE/FINAL_WARM
nameFinal Warm
order14
initialFalse
finalFalse
codeLPNHE
nameLaboratoire de Physique Nucléaire et de Hautes Energies

Current Stage: Ranking of the module

Test Type Local Result
Module ranking
(RANKING)
No TestRun! TestRun is missing in LocalDB.

Candidate TestRuns of this Stage

LocalDB Object ID TestRun Code QC Passed Inspector Date Analysis Version QC Registration
67d146530548d7bb612a73b3 IV_MEASURE Passed FrancescoCrescioli 2025-03-12 04:11:23 PDT(-0700) 2.3.1rc4 Selected
67d148a1b766a148ccad9aa4 E_SUMMARY Failed FrancescoCrescioli 2025-03-12 04:11:21 PDT(-0700) 2.2.39-rc9 Selected

Past QC Stages and Results

  Stage: Final flatness measurement (MODULE/FINAL_METROLOGY) Complete

Test Local Result ProdDB Record
Flatness
(FLATNESS)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!

  Stage: Final Cold (MODULE/FINAL_COLD) Complete

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
IV measurement
(IV_MEASURE)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
Visual Inspection
(VISUAL_INSPECTION)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!

  Stage: Final Warm (MODULE/FINAL_WARM) Complete

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
IV measurement
(IV_MEASURE)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
Visual Inspection
(VISUAL_INSPECTION)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.

  Stage: Long Term Stability Test (MODULE/LONG_TERM_STABILITY_TEST) Complete

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
IV measurement
(IV_MEASURE)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
Longterm stability DCS
(LONG_TERM_STABILITY_DCS)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!

  Stage: Thermal Cycles (MODULE/THERMAL_CYCLES) Complete

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
Flatness
(FLATNESS)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
IV measurement
(IV_MEASURE)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
Thermal Cycling
(THERMAL_CYCLING)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
Visual Inspection
(VISUAL_INSPECTION)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.

  Stage: Wirebond Protection (alt) (MODULE/WIREBOND_PROTECTION) Complete

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
IV measurement
(IV_MEASURE)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
Mass Measurement
(MASS_MEASUREMENT)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
Visual Inspection
(VISUAL_INSPECTION)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
Wire bonding protection roof envelope
(WP_ENVELOPE)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!

  Stage: Post-Parylene Cold (MODULE/POST_PARYLENE_COLD) Complete

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
IV measurement
(IV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Visual Inspection
(VISUAL_INSPECTION)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.

  Stage: Post-Parylene Warm (MODULE/POST_PARYLENE_WARM) Complete

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
IV measurement
(IV_MEASURE)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
Visual Inspection
(VISUAL_INSPECTION)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.

  Stage: Parylene Unmasking (MODULE/PARYLENE_UNMASKING) Complete

Test Local Result ProdDB Record
Parylene (de-)masking
(DE_MASKING)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Flatness
(FLATNESS)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
IV measurement
(IV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Visual Inspection
(VISUAL_INSPECTION)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!

  Stage: Parylene Coating (MODULE/PARYLENE_COATING) Complete

Test Local Result ProdDB Record
Parylene Properties
(PARYLENE)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
Visual Inspection
(VISUAL_INSPECTION)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!

  Stage: Parylene Masking (MODULE/PARYLENE_MASKING) Complete

Test Local Result ProdDB Record
Parylene (de-)masking
(DE_MASKING)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Visual Inspection
(VISUAL_INSPECTION)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!

  Stage: Initial Cold (MODULE/INITIAL_COLD) Complete

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
IV measurement
(IV_MEASURE)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!

  Stage: QC cross-check (module swapping) (MODULE/QC_CROSSCHECK) Alternative

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
IV measurement
(IV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.

  Stage: Initial Warm (MODULE/INITIAL_WARM) Complete

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
IV measurement
(IV_MEASURE)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!

  Stage: Wire Bonding (MODULE/WIREBONDING) Complete

Test Local Result ProdDB Record
Visual Inspection
(VISUAL_INSPECTION)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
Wirebond pull test
(WIREBOND_PULL_TEST)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
Wirebonding Information
(WIREBONDING)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!

  Stage: Bare module to module PCB assembly (MODULE/ASSEMBLY) Complete

Test Local Result ProdDB Record
Flatness
(FLATNESS)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
Glue Information Module+Flex Attach
(GLUE_MODULE_FLEX_ATTACH)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
Mass Measurement
(MASS_MEASUREMENT)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
Quad Module Metrology
(QUAD_MODULE_METROLOGY)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
Triplet Module Metrology
(TRIPLET_METROLOGY)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Visual Inspection
(VISUAL_INSPECTION)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!

  Stage: Initial state to associate flex to bare module (MODULE/INIT) Complete

No tests are allocated for this stage.

LocalDB Test ID Stage Test Name Inspector Date QC Registration
67d4220163915f8c483f5e57 MODULE/FINAL_METROLOGY FLATNESS FrancescoCrescioli 2025-03-14 05:33:39 PDT(-0700) Selected
67d2ad6e63915f8c483f5ab4 MODULE/FINAL_COLD VISUAL_INSPECTION FrancescoCrescioli 2025-03-14 04:58:36 PDT(-0700) Selected
67d4191a2c3197d918bd0652 MODULE/FINAL_COLD IV_MEASURE FrancescoCrescioli 2025-03-14 04:57:57 PDT(-0700) Selected
67d4195e2c3197d918bd0653 MODULE/FINAL_COLD E_SUMMARY FrancescoCrescioli 2025-03-14 04:57:55 PDT(-0700) Selected
67d146530548d7bb612a73b3 MODULE/FINAL_WARM IV_MEASURE FrancescoCrescioli 2025-03-12 04:11:23 PDT(-0700) Selected
67d148a1b766a148ccad9aa4 MODULE/FINAL_WARM E_SUMMARY FrancescoCrescioli 2025-03-12 04:11:21 PDT(-0700) Selected
67d16906b43e0b9f6c665037 MODULE/LONG_TERM_STABILITY_TEST LONG_TERM_STABILITY_DCS FrancescoCrescioli 2025-03-12 04:02:02 PDT(-0700) Selected
67d16955b43e0b9f6c665041 MODULE/LONG_TERM_STABILITY_TEST IV_MEASURE FrancescoCrescioli 2025-03-12 04:01:59 PDT(-0700) Selected
67d169740a3ada6da0982ba0 MODULE/LONG_TERM_STABILITY_TEST E_SUMMARY FrancescoCrescioli 2025-03-12 04:01:56 PDT(-0700) Selected
67caafab0a3ada6da0980839 MODULE/THERMAL_CYCLES IV_MEASURE FrancescoCrescioli 2025-03-10 01:12:37 PDT(-0700) Selected
67c9a12b0548d7bb612a6215 MODULE/THERMAL_CYCLES THERMAL_CYCLING FrancescoCrescioli 2025-03-10 01:12:35 PDT(-0700) Selected
67cb073763915f8c483f43c0 MODULE/THERMAL_CYCLES E_SUMMARY FrancescoCrescioli 2025-03-10 01:12:33 PDT(-0700) Selected
67afd361d72402b42d68631e MODULE/WIREBOND_PROTECTION IV_MEASURE FrancescoCrescioli 2025-03-04 05:35:01 PST(-0800) Selected
67c1f03db32180bc4f1b6207 MODULE/WIREBOND_PROTECTION VISUAL_INSPECTION FrancescoCrescioli 2025-03-04 05:34:59 PST(-0800) Selected
67c1da425c030bc16032882c MODULE/WIREBOND_PROTECTION MASS_MEASUREMENT FrancescoCrescioli 2025-03-04 05:34:51 PST(-0800) Selected
67c1eb13f61020594361e140 MODULE/WIREBOND_PROTECTION WP_ENVELOPE FrancescoCrescioli 2025-03-04 05:34:49 PST(-0800) Selected
67c7010998f3f2d52b0ed275 MODULE/WIREBOND_PROTECTION E_SUMMARY FrancescoCrescioli 2025-03-04 05:34:48 PST(-0800) Selected
6796baa16b9824a8f0a6b374 MODULE/POST_PARYLENE_WARM IV_MEASURE FrancescoCrescioli 2025-02-27 01:53:36 PST(-0800) Selected
67976301697bdecd4bb7bcf8 MODULE/POST_PARYLENE_WARM E_SUMMARY FrancescoCrescioli 2025-02-27 01:53:34 PST(-0800) Selected
6799fb0b6b9824a8f0a6b923 MODULE/PARYLENE_UNMASKING DE_MASKING FrancescoCrescioli 2025-02-27 01:53:08 PST(-0800) Selected
679a01c549925215807a864f MODULE/PARYLENE_UNMASKING VISUAL_INSPECTION FrancescoCrescioli 2025-02-27 01:53:07 PST(-0800) Selected
6799fa706b9824a8f0a6b921 MODULE/PARYLENE_COATING VISUAL_INSPECTION FrancescoCrescioli 2025-02-27 01:52:26 PST(-0800) Selected
67bdc3342c70493438715b15 MODULE/PARYLENE_COATING PARYLENE FrancescoCrescioli 2025-02-27 01:52:06 PST(-0800) Selected
6789145337aa41648a78be9b MODULE/PARYLENE_MASKING VISUAL_INSPECTION FrancescoCrescioli 2025-01-17 02:52:15 PST(-0800) Selected
672b295edd7bc220d092bfde MODULE/INITIAL_COLD IV_MEASURE FrancescoCrescioli 2025-01-15 12:34:19 PST(-0800) Selected
677e9762449c8bfcaa54dfe5 MODULE/INITIAL_COLD E_SUMMARY FrancescoCrescioli 2025-01-15 12:34:15 PST(-0800) Selected
6728b2b4f1c6980b770547b8 MODULE/INITIAL_WARM IV_MEASURE FrancescoCrescioli 2025-01-15 12:27:33 PST(-0800) Selected
677e39b141fd5a07abc1e27f MODULE/INITIAL_WARM E_SUMMARY FrancescoCrescioli 2025-01-15 12:27:30 PST(-0800) Selected
67878dcf37aa41648a78ba14 MODULE/WIREBONDING VISUAL_INSPECTION FrancescoCrescioli 2025-01-15 08:50:14 PST(-0800) Selected
673c633ee4b58fe6729aab78 MODULE/WIREBONDING WIREBOND_PULL_TEST FrancescoCrescioli 2025-01-15 08:49:53 PST(-0800) Selected
6787871260382cf595ca43d4 MODULE/WIREBONDING WIREBONDING FrancescoCrescioli 2025-01-15 08:49:52 PST(-0800) Selected
6786291b38efa70a43c00d07 MODULE/ASSEMBLY GLUE_MODULE_FLEX_ATTACH FrancescoCrescioli 2025-01-14 01:06:35 PST(-0800) Selected
678620ab38efa70a43bfee63 MODULE/ASSEMBLY FLATNESS FrancescoCrescioli 2025-01-14 00:35:12 PST(-0800) Selected
67815ea045bf3b66d94c21c6 MODULE/ASSEMBLY QUAD_MODULE_METROLOGY PaulMickael Chabrillat 2025-01-10 09:53:57 PST(-0800) Selected
6710d740dbf10bfd2c213c81 MODULE/ASSEMBLY VISUAL_INSPECTION FrancescoCrescioli 2025-01-09 10:08:36 PST(-0800) Selected
6710b9b6eff9780043ad3aad MODULE/ASSEMBLY MASS_MEASUREMENT FrancescoCrescioli 2025-01-09 10:07:07 PST(-0800) Selected
Stage Tests
MODULE/INIT
MODULE/ASSEMBLY
  • Mass Measurement  (MASS_MEASUREMENT)
  • Glue Information Module+Flex Attach  (GLUE_MODULE_FLEX_ATTACH)
  • Triplet Module Metrology  (TRIPLET_METROLOGY)
  • Visual Inspection  (VISUAL_INSPECTION)
  • Flatness  (FLATNESS)
  • Quad Module Metrology  (QUAD_MODULE_METROLOGY)
MODULE/WIREBONDING
  • Wirebonding Information  (WIREBONDING)
  • Wirebond pull test  (WIREBOND_PULL_TEST)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/INITIAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/QC_CROSSCHECK
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/INITIAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/PARYLENE_MASKING
  • Visual Inspection  (VISUAL_INSPECTION)
  • Parylene (de-)masking  (DE_MASKING)
MODULE/PARYLENE_COATING
  • Parylene Properties  (PARYLENE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/PARYLENE_UNMASKING
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Parylene (de-)masking  (DE_MASKING)
MODULE/POST_PARYLENE_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/POST_PARYLENE_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/WIREBOND_PROTECTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Wire bonding protection roof envelope  (WP_ENVELOPE)
  • Mass Measurement  (MASS_MEASUREMENT)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
MODULE/THERMAL_CYCLES
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Thermal Cycling  (THERMAL_CYCLING)
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
MODULE/LONG_TERM_STABILITY_TEST
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Longterm stability DCS  (LONG_TERM_STABILITY_DCS)
MODULE/FINAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/FINAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/FINAL_METROLOGY
  • Flatness  (FLATNESS)
MODULE/QC_STATUS
  • Module ranking  (RANKING)
MODULE/UNHAPPY
MODULE/NOTCONSIDEREDINYIELDS
MODULE/COMPLETE
MODULE/RECEPTION
  • Visual Inspection  (VISUAL_INSPECTION)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/TAB_CUTTING
  • Mass Measurement  (MASS_MEASUREMENT)
  • Module PCB Tab Cutting Information  (CUTTER_PCB_TAB)
  • Visual Inspection  (VISUAL_INSPECTION)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/INIT
OB_LOADED_MODULE_CELL/ASSEMBLY
OB_LOADED_MODULE_CELL/THERMAL_CYCLES
OB_LOADED_MODULE_CELL/FINAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/FINAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/THERMAL_COLD
  • Thermal Measure  (THERMAL_PERFORMANCE)
OB_LOADED_MODULE_CELL/THERMAL_WARM
  • Thermal Measure  (THERMAL_PERFORMANCE)
OB_LOADED_MODULE_CELL/ENVELOPE_CHECK
OB_LOADED_MODULE_CELL/QC_STATUS
OB_LOADED_MODULE_CELL/UNHAPPY
OB_LOADED_MODULE_CELL/COMPLETE
OB_LOADED_MODULE_CELL/RECEPTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/TAB_CUTTING
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Module PCB Tab Cutting Information  (CUTTER_PCB_TAB)
OB_LOADED_MODULE_CELL/PIGTAIL_INSERTION
Back to top page of this component