Top Page > Component List > 20UPGS33303578 > QC Result / BAREMODULERECEPTION / IV_MEASURE


20UPGS33303578
Outer-Quad-Sensor
  ITkPD Component Page Jump to ITkPD component page

Component Information

Item Value
Serial Number 20UPGS33303578
Production DB Component ID 4c49fec03cdf13aca310a6cc5c1945ae
LocalDB Component ID 66f6b645db678200433738f2
Component Type sensor_tile
Super-Component 20UPGB43200080
Sub-Components No match.
Flags

Properties

Item Data Type Value
Main Vendor integer 3
Sensor Type or Test Structure integer 3
Version of component string production
Scratch id (to be used if not the same as agreed manufacturer ID) string 7003
Alternative Identifier string V4-2-007003-3-001
Original Manufacturer ID string Q1
Breakdown Voltage (-999 if no breakdown occurred) float -999
Depletion Voltage (V) float 58.74

Comments


Test: IV_MEASURE QC Passed

(Stage: BAREMODULERECEPTION)


Basic View Only: custom view for this TestRun is not prepared.

Metadata

Key Data
QC Passed True
Date 2025-01-22 00:51:44 PST(-0800)
component ObjectId 66f6b645db678200433738f2
Stage BAREMODULERECEPTION
Test Type IV_MEASURE
Institute ObjectId
User Name MarioJose
ObjectId of this record 6790b1a04d1c6006c3fc1ae7
ObjectId of RAW record None

Results

Key Data
ANALYSIS_VERSION mqat vwebApp SHA:53c288c
HUM 27
TEMP 25
BREAKDOWN_VOLTAGE -999
IV_ARRAY {'voltage': [0, 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 105, 110, 115, 120, 125, 130, 135, 140, 145, 150, 155, 160, 165, 170, 175, 180, 185, 190, 195, 200], 'current': [0.002329015, 0.634218, 0.716184, 0.7682047999999999, 0.8065605, 0.8369615, 0.8632055, 0.8827924, 0.8990296, 0.9119634999999999, 0.923921, 0.9334979999999999, 0.940887, 0.9482505, 0.9532486, 0.9612672, 0.9656214000000001, 0.9707758, 0.974816, 0.9815736, 0.9838640000000001, 0.9863881999999999, 0.9910952000000001, 0.9952927, 0.9979585000000001, 1.00012, 1.006172, 1.007299, 1.009394, 1.014286, 1.017293, 1.019772, 1.024357, 1.02375, 1.027943, 1.034234, 1.033934, 1.036621, 1.042338, 1.050022, 1.050021], 'sigma current': [0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0], 'temperature': [25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25], 'humidity': [27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27]}
LEAK_CURRENT 0.9863881999999999
MAXIMUM_VOLTAGE 200
NO_BREAKDOWN_VOLTAGE_OBSERVED True

ProductionDB Record

{}

Current Stage: Wafer Processing (dicing, UBM, flip-chip)

Test Type Local Result
Visual inspection
(VISUAL_INSPECTION)
No TestRun! TestRun is missing in LocalDB.
Sensor Metrology: Sensor bow and thickness
(SENSOR_METROLOGY)
No TestRun! TestRun is missing in LocalDB.
IV measurement
(IV_MEASURE)
No TestRun! TestRun is missing in LocalDB.
CV measurement
(CV_MEASURE)
No TestRun! TestRun is missing in LocalDB.

Candidate TestRuns of this Stage

LocalDB Object ID TestRun Code QC Passed Inspector Date Analysis Version QC Registration
6790b1a04d1c6006c3fc1ae7 IV_MEASURE Passed MarioJose 2025-01-22 00:51:44 PST(-0800) webApp SHA:53c288c Selected

Past QC Stages and Results

  Stage: Sensor Manufacturer (sensor_manufacturer) Complete

Test Local Result ProdDB Record
CV measurement
(CV_MEASURE)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
IV measurement
(IV_MEASURE)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
LocalDB Test ID Stage Test Name Inspector Date QC Registration
6790b1a04d1c6006c3fc1ae7 BAREMODULERECEPTION IV_MEASURE MarioJose 2025-01-22 00:51:44 PST(-0800) Selected
66f6c6ea13e0b00043294c5a sensor_manufacturer IV_MEASURE JörnGroße-Knetter 2024-09-27 07:53:30 PDT(-0700) Selected
66f6c422db6782004337aa8b sensor_manufacturer CV_MEASURE JörnGroße-Knetter 2024-09-27 07:41:38 PDT(-0700) Selected
Stage Tests
sensor_manufacturer
  • CV measurement  (CV_MEASURE)
  • IV measurement  (IV_MEASURE)
WAFER_PROCESSING
  • Visual inspection  (VISUAL_INSPECTION)
  • Sensor Metrology: Sensor bow and thickness  (SENSOR_METROLOGY)
  • IV measurement  (IV_MEASURE)
  • CV measurement  (CV_MEASURE)
QA
  • CV measurement  (CV_MEASURE)
  • IV measurement  (IV_MEASURE)
  • IT measurement  (IT_MEASURE)
  • Inter-pixel capacitance  (INTER-PIXEL_CAPACITANCE)
  • Inter-pixel resistance  (INTER-PIXEL_RESISTANCE)
  • Sensor Metrology: Sensor bow and thickness  (SENSOR_METROLOGY)
POST_IRRAD
  • IV measurement  (IV_MEASURE)
  • CV measurement  (CV_MEASURE)
NOT_USED
BAREMODULEASSEMBLY
BAREMODULERECEPTION
  • IV measurement  (IV_MEASURE)
MODULE/INIT
MODULE/ASSEMBLY
MODULE/WIREBONDING
MODULE/INITIAL_WARM
MODULE/QC_CROSSCHECK
MODULE/INITIAL_COLD
MODULE/PARYLENE_MASKING
MODULE/PARYLENE_COATING
MODULE/PARYLENE_UNMASKING
MODULE/POST_PARYLENE_WARM
MODULE/POST_PARYLENE_COLD
MODULE/WIREBOND_PROTECTION
MODULE/THERMAL_CYCLES
MODULE/LONG_TERM_STABILITY_TEST
MODULE/FINAL_WARM
MODULE/FINAL_COLD
MODULE/FINAL_METROLOGY
MODULE/QC_STATUS
MODULE/UNHAPPY
MODULE/NOTCONSIDEREDINYIELDS
MODULE/COMPLETE
MODULE/RECEPTION
MODULE/TAB_CUTTING
OB_LOADED_MODULE_CELL/INIT
OB_LOADED_MODULE_CELL/ASSEMBLY
OB_LOADED_MODULE_CELL/THERMAL_CYCLES
OB_LOADED_MODULE_CELL/FINAL_WARM
OB_LOADED_MODULE_CELL/FINAL_COLD
OB_LOADED_MODULE_CELL/THERMAL_COLD
OB_LOADED_MODULE_CELL/THERMAL_WARM
OB_LOADED_MODULE_CELL/ENVELOPE_CHECK
OB_LOADED_MODULE_CELL/QC_STATUS
OB_LOADED_MODULE_CELL/UNHAPPY
OB_LOADED_MODULE_CELL/COMPLETE
OB_LOADED_MODULE_CELL/RECEPTION
OB_LOADED_MODULE_CELL/TAB_CUTTING
OB_LOADED_MODULE_CELL/PIGTAIL_INSERTION
Back to top page of this component