Top Page > Component List > 20UPGS33303578 > QC Result / BAREMODULERECEPTION / IV_MEASURE
Item | Value |
---|---|
Serial Number | 20UPGS33303578 |
Production DB Component ID | 4c49fec03cdf13aca310a6cc5c1945ae |
LocalDB Component ID | 66f6b645db678200433738f2 |
Component Type | sensor_tile |
Super-Component | 20UPGB43200080 |
Sub-Components | No match. |
Flags |
Key | Data |
---|---|
QC Passed | True |
Date | 2025-01-22 00:51:44 PST(-0800) |
component ObjectId | 66f6b645db678200433738f2 |
Stage | BAREMODULERECEPTION |
Test Type | IV_MEASURE |
Institute ObjectId | |
User Name | MarioJose |
ObjectId of this record | 6790b1a04d1c6006c3fc1ae7 |
ObjectId of RAW record | None |
Key | Data |
---|---|
ANALYSIS_VERSION | mqat vwebApp SHA:53c288c |
HUM | 27 |
TEMP | 25 |
BREAKDOWN_VOLTAGE | -999 |
IV_ARRAY | {'voltage': [0, 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 105, 110, 115, 120, 125, 130, 135, 140, 145, 150, 155, 160, 165, 170, 175, 180, 185, 190, 195, 200], 'current': [0.002329015, 0.634218, 0.716184, 0.7682047999999999, 0.8065605, 0.8369615, 0.8632055, 0.8827924, 0.8990296, 0.9119634999999999, 0.923921, 0.9334979999999999, 0.940887, 0.9482505, 0.9532486, 0.9612672, 0.9656214000000001, 0.9707758, 0.974816, 0.9815736, 0.9838640000000001, 0.9863881999999999, 0.9910952000000001, 0.9952927, 0.9979585000000001, 1.00012, 1.006172, 1.007299, 1.009394, 1.014286, 1.017293, 1.019772, 1.024357, 1.02375, 1.027943, 1.034234, 1.033934, 1.036621, 1.042338, 1.050022, 1.050021], 'sigma current': [0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0], 'temperature': [25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25, 25], 'humidity': [27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27, 27]} |
LEAK_CURRENT | 0.9863881999999999 |
MAXIMUM_VOLTAGE | 200 |
NO_BREAKDOWN_VOLTAGE_OBSERVED | True |
Test Type | Local Result |
---|---|
Visual inspection (VISUAL_INSPECTION) |
No TestRun!
TestRun is missing in LocalDB.
|
Sensor Metrology: Sensor bow and thickness (SENSOR_METROLOGY) |
No TestRun!
TestRun is missing in LocalDB.
|
IV measurement (IV_MEASURE) |
No TestRun!
TestRun is missing in LocalDB.
|
CV measurement (CV_MEASURE) |
No TestRun!
TestRun is missing in LocalDB.
|
LocalDB Object ID | TestRun Code | QC Passed | Inspector | Date | Analysis Version | QC Registration |
---|---|---|---|---|---|---|
6790b1a04d1c6006c3fc1ae7 | IV_MEASURE | Passed | MarioJose | 2025-01-22 00:51:44 PST(-0800) | webApp SHA:53c288c | Selected |
Test | Local Result | ProdDB Record |
---|---|---|
CV measurement (CV_MEASURE) |
Registered
Jump to the LocalDB Test Record!
|
Registered
Jump to the ITkPD TestRun Page!
|
IV measurement (IV_MEASURE) |
Registered
Jump to the LocalDB Test Record!
|
Registered
Jump to the ITkPD TestRun Page!
|
LocalDB Test ID | Stage | Test Name | Inspector | Date | QC Registration |
---|---|---|---|---|---|
6790b1a04d1c6006c3fc1ae7 | BAREMODULERECEPTION | IV_MEASURE | MarioJose | 2025-01-22 00:51:44 PST(-0800) | Selected |
66f6c6ea13e0b00043294c5a | sensor_manufacturer | IV_MEASURE | JörnGroße-Knetter | 2024-09-27 07:53:30 PDT(-0700) | Selected |
66f6c422db6782004337aa8b | sensor_manufacturer | CV_MEASURE | JörnGroße-Knetter | 2024-09-27 07:41:38 PDT(-0700) | Selected |
Stage | Tests |
---|---|
sensor_manufacturer |
|
WAFER_PROCESSING |
|
QA |
|
POST_IRRAD |
|
NOT_USED |
|
BAREMODULEASSEMBLY |
|
BAREMODULERECEPTION |
|
MODULE/INIT |
|
MODULE/ASSEMBLY |
|
MODULE/WIREBONDING |
|
MODULE/INITIAL_WARM |
|
MODULE/QC_CROSSCHECK |
|
MODULE/INITIAL_COLD |
|
MODULE/PARYLENE_MASKING |
|
MODULE/PARYLENE_COATING |
|
MODULE/PARYLENE_UNMASKING |
|
MODULE/POST_PARYLENE_WARM |
|
MODULE/POST_PARYLENE_COLD |
|
MODULE/WIREBOND_PROTECTION |
|
MODULE/THERMAL_CYCLES |
|
MODULE/LONG_TERM_STABILITY_TEST |
|
MODULE/FINAL_WARM |
|
MODULE/FINAL_COLD |
|
MODULE/FINAL_METROLOGY |
|
MODULE/QC_STATUS |
|
MODULE/UNHAPPY |
|
MODULE/NOTCONSIDEREDINYIELDS |
|
MODULE/COMPLETE |
|
MODULE/RECEPTION |
|
MODULE/TAB_CUTTING |
|
OB_LOADED_MODULE_CELL/INIT |
|
OB_LOADED_MODULE_CELL/ASSEMBLY |
|
OB_LOADED_MODULE_CELL/THERMAL_CYCLES |
|
OB_LOADED_MODULE_CELL/FINAL_WARM |
|
OB_LOADED_MODULE_CELL/FINAL_COLD |
|
OB_LOADED_MODULE_CELL/THERMAL_COLD |
|
OB_LOADED_MODULE_CELL/THERMAL_WARM |
|
OB_LOADED_MODULE_CELL/ENVELOPE_CHECK |
|
OB_LOADED_MODULE_CELL/QC_STATUS |
|
OB_LOADED_MODULE_CELL/UNHAPPY |
|
OB_LOADED_MODULE_CELL/COMPLETE |
|
OB_LOADED_MODULE_CELL/RECEPTION |
|
OB_LOADED_MODULE_CELL/TAB_CUTTING |
|
OB_LOADED_MODULE_CELL/PIGTAIL_INSERTION |
|