20UPGS33302092

MODULE/PARYLENE_UNMASKING

Component Information

Serial Number 20UPGS33302092
ProdDB ID  77cca4…9311fb
LocalDB ID 6627488fb345a200357fd1d0
Component Type SENSOR_TILE
Parents 20UPGB43347167
Children No match.
Flags

 Properties

Item Value
Main Vendor readonly 3
Sensor Type or Test Structure readonly 3
Version of component production
Scratch id (to be used if not the same as agreed manufacturer ID) 352
Alternative Identifier V4-2-000352-3-003
Original Manufacturer ID Q3
Breakdown Voltage (-999 if no breakdown occurred) -999
Depletion Voltage (V) 55.71

 Comments


Test: IV_MEASURE QC Passed

(Stage: BAREMODULERECEPTION)


Basic View Only: custom view for this TestRun is not prepared.

Metadata

Key Data
QC Passed True
Date 6 months ago
component ObjectId 6627488fb345a200357fd1d0
Stage BAREMODULERECEPTION
Test Type IV_MEASURE
Institute ObjectId
User Name YujiEnari
ObjectId of this record 68f5d86b8bc3fa9c0b9f0717
ObjectId of RAW record 68f5d86a8bc3fa9c0b9f0710
Tags No tags

Results

Key Data
ANALYSIS_VERSION mqat v2.3.1.dev27
HUM 0
MEASUREMENT_DATE 2025-10-20T15:36:26.000+00:00
TEMP 20
BREAKDOWN_REDUCTION 0
BREAKDOWN_VOLTAGE -999
IV_ARRAY {'time': [0, 7, 14, 21, 28, 35, 42, 49, 56, 62, 69, 76, 83, 90, 97, 104, 111, 118, 125, 132, 139, 146, 153, 160, 167, 174, 181, 188, 195, 202, 209, 216, 223, 230, 237, 244, 250, 257, 264, 271, 278], 'voltage': [0, 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 105, 110, 115, 120, 125, 130, 135, 140, 145, 150, 155, 160, 165, 170, 175, 180, 185, 190, 195, 200], 'current': [0.015522300000000003, 0.0570709, 0.06203070000000001, 0.0652409, 0.0675009, 0.06914580000000001, 0.0702508, 0.0711087, 0.0718245, 0.0724104, 0.07292950000000001, 0.0736409, 0.0752356, 0.0757922, 0.07613539999999999, 0.07671299999999999, 0.07721940000000001, 0.0776588, 0.0781068, 0.0787764, 0.0793456, 0.07983950000000001, 0.0803669, 0.0808984, 0.08133370000000001, 0.0819824, 0.08252649999999999, 0.082853, 0.08328400000000001, 0.0837487, 0.08437650000000001, 0.08480760000000001, 0.0853808, 0.0859418, 0.0865026, 0.0871011, 0.0876411, 0.0883024, 0.08891349999999999, 0.0896375, 0.0901816], 'sigma current': [0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0], 'temperature': [20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20, 20], 'humidity': [0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0]}
LEAK_CURRENT 0.0803669
LEAK_PER_AREA 0.01
LEAK_INCREASE_FACTOR 0.87
MAXIMUM_VOLTAGE 200
NO_BREAKDOWN_VOLTAGE_OBSERVED True

Attachments

Filename Contents
output.log Download
20UPGS33302092_plot.png
20UPGS33302092_summary.png

RAW Results Record

Download RAW
_id68f5d86a8bc3fa9c0b9f0710
raw
serialNumbertestTypesubtestTyperesultsstagecomponentdbVersionaddresssys
20UPGS33302092IV_MEASURE
property
TEMPNone
HUMNone
ANALYSIS_VERSIONNone
MEASUREMENT_DATENone
comment
Metadata
QCHELPER_VERSION0.1.1.dev5
MODULE_SN20UPGS33302092
Institution
Measurements
IV_ARRAY
time
  • 0
  • 7
  • 14
  • 21
  • 28
  • 35
  • 42
  • 49
  • 56
  • 62
  • 69
  • 76
  • 83
  • 90
  • 97
  • 104
  • 111
  • 118
  • 125
  • 132
  • 139
  • 146
  • 153
  • 160
  • 167
  • 174
  • 181
  • 188
  • 195
  • 202
  • 209
  • 216
  • 223
  • 230
  • 237
  • 244
  • 250
  • 257
  • 264
  • 271
  • 278
voltage
  • -0.0
  • 5.0
  • 10.0
  • 15.0
  • 20.0
  • 25.0
  • 30.0
  • 35.0
  • 40.0
  • 45.0
  • 50.0
  • 55.0
  • 60.0
  • 65.0
  • 70.0
  • 75.0
  • 80.0
  • 85.0
  • 90.0
  • 95.0
  • 100.0
  • 105.0
  • 110.0
  • 115.0
  • 120.0
  • 125.0
  • 130.0
  • 135.0
  • 140.0
  • 145.0
  • 150.0
  • 155.0
  • 160.0
  • 165.0
  • 170.0
  • 175.0
  • 180.0
  • 185.0
  • 190.0
  • 195.0
  • 200.0
current
  • -0.015522300000000001
  • 0.0570709
  • 0.06203070000000001
  • 0.0652409
  • 0.0675009
  • 0.06914580000000001
  • 0.0702508
  • 0.0711087
  • 0.0718245
  • 0.0724104
  • 0.07292950000000001
  • 0.0736409
  • 0.0752356
  • 0.0757922
  • 0.07613539999999999
  • 0.07671299999999999
  • 0.07721940000000001
  • 0.0776588
  • 0.0781068
  • 0.0787764
  • 0.0793456
  • 0.07983950000000001
  • 0.0803669
  • 0.0808984
  • 0.08133370000000001
  • 0.0819824
  • 0.08252649999999999
  • 0.082853
  • 0.08328400000000001
  • 0.0837487
  • 0.08437650000000001
  • 0.08480760000000001
  • 0.0853808
  • 0.0859418
  • 0.0865026
  • 0.0871011
  • 0.0876411
  • 0.0883024
  • 0.08891349999999999
  • 0.0896375
  • 0.0901816
sigma current
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
temperature
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
  • 20
humidity
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
  • 0
BREAKDOWN_VOLTAGENone
LEAK_CURRENTNone
MAXIMUM_VOLTAGENone
NO_BREAKDOWN_VOLTAGE_OBSERVEDNone
LEAK_PER_AREANone
BREAKDOWN_REDUCTIONNone
LEAK_INCREASE_FACTORNone
BAREMODULERECEPTION6627488fb345a200357fd1d01.0164657cef8d79bac1f3f0057a
mts2025-10-20 06:36:26.458000
cts2025-10-20 06:36:26.458000
rev0
rawHash8e5b911f1618eb2a5eff89e93b4122da
stageBAREMODULERECEPTION

ProductionDB Record

id68fbc0c4ecbbcc3f84ce937f
stateready
stateTs2025-10-24T18:09:08.741Z
stateUserIdentity4940-829-1
date2025-10-20T06:36:00.000Z
testType
id5b1a3abf130f5600054a42a8
codeIV_MEASURE
nameIV measurement
stateactive
institution
id5d31879ddf98f200097387f5
codeKEK
nameHigh Energy Accelerator Research Organization (KEK)
user
id669834593510e900431bfe36
userIdentity4940-829-1
firstNameYuji
middleName
lastNameEnari
runNumber68f5d86b8bc3fa9c0b9f0717
passedTrue
problemsFalse
properties
codenamedataTypevalueTyperequiredvaluerangeMinrangeMax
ANALYSIS_VERSIONAnalysis VersionstringsingleFalse2.3.1.dev27NoneNone
HUMHumidity [%]floatsingleTrue0NoneNone
MEASUREMENT_DATEDate measurement performeddatetimesingleFalse2025-10-20T15:36:26.000+00:00NoneNone
TEMPTemperature [°C]floatsingleTrue20NoneNone
results
  • codeBREAKDOWN_REDUCTION
    nameBreakdown Voltage Reduction (V)
    order8
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value0
    associateChildNone
  • codeBREAKDOWN_VOLTAGE
    nameBreakdown voltage [V] (if no breakdown put -999)
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    value-999
    associateChildNone
  • codeIV_ARRAY
    nameIV data
    dataTypeobject
    valueTypesingle
    arrayDimensions1
    additionalFalse
    value
    time
    • 0
    • 7
    • 14
    • 21
    • 28
    • 35
    • 42
    • 49
    • 56
    • 62
    • 69
    • 76
    • 83
    • 90
    • 97
    • 104
    • 111
    • 118
    • 125
    • 132
    • 139
    • 146
    • 153
    • 160
    • 167
    • 174
    • 181
    • 188
    • 195
    • 202
    • 209
    • 216
    • 223
    • 230
    • 237
    • 244
    • 250
    • 257
    • 264
    • 271
    • 278
    voltage
    • 0
    • 5
    • 10
    • 15
    • 20
    • 25
    • 30
    • 35
    • 40
    • 45
    • 50
    • 55
    • 60
    • 65
    • 70
    • 75
    • 80
    • 85
    • 90
    • 95
    • 100
    • 105
    • 110
    • 115
    • 120
    • 125
    • 130
    • 135
    • 140
    • 145
    • 150
    • 155
    • 160
    • 165
    • 170
    • 175
    • 180
    • 185
    • 190
    • 195
    • 200
    current
    • 0.015522300000000003
    • 0.0570709
    • 0.06203070000000001
    • 0.0652409
    • 0.0675009
    • 0.06914580000000001
    • 0.0702508
    • 0.0711087
    • 0.0718245
    • 0.0724104
    • 0.07292950000000001
    • 0.0736409
    • 0.0752356
    • 0.0757922
    • 0.07613539999999999
    • 0.07671299999999999
    • 0.07721940000000001
    • 0.0776588
    • 0.0781068
    • 0.0787764
    • 0.0793456
    • 0.07983950000000001
    • 0.0803669
    • 0.0808984
    • 0.08133370000000001
    • 0.0819824
    • 0.08252649999999999
    • 0.082853
    • 0.08328400000000001
    • 0.0837487
    • 0.08437650000000001
    • 0.08480760000000001
    • 0.0853808
    • 0.0859418
    • 0.0865026
    • 0.0871011
    • 0.0876411
    • 0.0883024
    • 0.08891349999999999
    • 0.0896375
    • 0.0901816
    sigma current
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    temperature
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    • 20
    humidity
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    • 0
    associateChildNone
  • codeLEAK_CURRENT
    nameLeakage current at depletion voltage + 20 (50) V for 3D (planar) sensors [μA]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    value0.0803669
    associateChildNone
  • codeLEAK_PER_AREA
    nameLeakage Current per Area (uA/cm^2)
    order1
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value0.01
    associateChildNone
  • codeLEAK_INCREASE_FACTOR
    nameLeakage Current Increase Factor
    order9
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value0.87
    associateChildNone
  • codeMAXIMUM_VOLTAGE
    nameMaximum measured Voltage [V]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value200
    associateChildNone
  • codeNO_BREAKDOWN_VOLTAGE_OBSERVED
    nameNo breakdown voltage observed
    dataTypeboolean
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    valueTrue
    associateChildNone
cts2025-10-24T18:09:08.741Z
sys
cts2025-10-24T18:09:08.741Z
mts2025-10-24T18:09:13.720Z
rev2
defects
commentsNone
attachments
  • code0c8fe9e4c2ddda0b04127e3bb92521a2
    dateTime2025-10-24T18:09:09.812Z
    titleTestRun_68fbc0c4ecbbcc3f84ce937f_Attachment_Pack.zip
    description/nas/db/localdb-tools-v2.2.38-rc1/viewer/static/cache/thumbnail/TestRun_68fbc0c4ecbbcc3f84ce937f_Attachment_Pack.zip
    contentTypeNone
    typeeos
    urlhttps://eosatlas.cern.ch/eos/atlas/atlascerngroupdisk/det-itk/prod-db/0/c/8/0c8fe9e4c2ddda0b04127e3bb92521a2?authz=zteos64:MDAwMDAyZjd4nO2RsUoDQRCGSUCLICgiCMFiDBY2d7e7d8ndTaWNRUqJVYiwe7uXnEluj7tNk1KxygvYBS18AcGnECJY6AtoZWsjFsZgYWFt5RRTfPzzMz9_5blcKeVrs6vzu-XqUmL6mayVx9luibUcpQuHmwH_3pHK026uR5lMir4jlbHmcifLtbSkcIgTOYFDoiBWofIiJqXkRBCPMl-5QoSszihnzR1fCC6FIBYhYWxRGlMroJFrcU_EhPphw2fh4X2p3RopOFACwAXCkPnICDDCGh0YJRKpRxsBbS_-7UD3i7jEb4-zDphEqtRgrrWxmUf8wK1jGHjhXhsxng_WqU1pww4Dm5IOpHyocOEDMkWYxzHYz0UdeJYh9HRh8PdDqYc8SfEH6SqNUIykRgIm55FC0KlQPT6IcR1eVrdO35qPJ9fvK5dFbfIxm15sHu1vPDwdw_Zt93VS_W_iT5qAm7Np5ROIUOtF
    urlCernboxhttps://cernbox.cern.ch/files/spaces/eos/atlas/atlascerngroupdisk/det-itk/prod-db/0/c/8/0c8fe9e4c2ddda0b04127e3bb92521a2
    filename0c8fe9e4c2ddda0b04127e3bb92521a2
    user
    id669834593510e900431bfe36
    userIdentity4940-829-1
    firstNameYuji
    middleName
    lastNameEnari
  • code8fe5f1a628b1ec697abed58934b13e08
    dateTime2025-10-24T18:09:13.481Z
    titleRAW
    descriptionRAW
    contentTypetext/plain
    typefile
    binaryStoreg02True
    filename20UPGS33302092_BAREMODULERECEPTION_IV_MEASURE_68fbc0c4ecbbcc3f84ce937f_68f5d86a8bc3fa9c0b9f0710.json
    user
    id669834593510e900431bfe36
    userIdentity4940-829-1
    firstNameYuji
    middleName
    lastNameEnari
components
idcodestatestateTsstateUserIdentitydummycompletedcompletedTscompletedUserIdentitytrashedtrashedTstrashedUserIdentityserialNumberalternativeIdentifierancestorMapprojectsubprojectcomponentTypetypepropertiestestedAtStageinstitution
6627488fb345a200357fd1d077cca4fb733feeb6853faf99529311fbready2024-04-23T05:35:11.093Z24-779-1FalseFalseNoneNoneFalseNoneNone20UPGS33302092V4-2-000352-3-003
parent
component
id68e8b5a6b5f1d1f55a4e220c
codebfe11a3f77d0a8c6f01dd672c5fd94f8
stateready
stateTs2025-10-10T07:28:38.245Z
stateUserIdentity24-779-1
dummyFalse
completedFalse
completedTsNone
completedUserIdentityNone
trashedFalse
trashedTsNone
trashedUserIdentityNone
serialNumber20UPGB43347167
alternativeIdentifierNone
project
codeP
namePixels
subproject
codePG
namePixel general
componentType
codeBARE_MODULE
nameBare Module
type
codeQUAD_BARE_MODULE
nameQuad bare module
testedAtStage
codeBAREMODULERECEPTION
nameReception at ITk institute
highestLevelParent
component
id68e8b5a6b5f1d1f55a4e220c
codebfe11a3f77d0a8c6f01dd672c5fd94f8
stateready
stateTs2025-10-10T07:28:38.245Z
stateUserIdentity24-779-1
dummyFalse
completedFalse
completedTsNone
completedUserIdentityNone
trashedFalse
trashedTsNone
trashedUserIdentityNone
serialNumber20UPGB43347167
alternativeIdentifierNone
project
codeP
namePixels
subproject
codePG
namePixel general
componentType
codeBARE_MODULE
nameBare Module
type
codeQUAD_BARE_MODULE
nameQuad bare module
testedAtStage
codeBAREMODULERECEPTION
nameReception at ITk institute
codeP
namePixels
codePG
namePixel general
codeSENSOR_TILE
nameSensor Tile
codeOUTER_PIXEL_QUAD_SENSOR_TILE
nameOuter Pixel Quad Sensor Tile
codenamedataTyperequireddefaultvalue
MAIN_VENDORMain VendorintegerTrueFalse3
SENSOR_TYPE_OR_TEST_STRUCTURESensor Type or Test StructureintegerTrueFalse3
VERSIONVersion of componentstringTrueFalseproduction
SENSOR_SCRATCHIDScratch id (to be used if not the same as agreed manufacturer ID)stringFalseFalse352
MAN_SNOAlternative IdentifierstringTrueTrueV4-2-000352-3-003
MAN_IDOriginal Manufacturer IDstringFalseFalseQ3
BREAKDOWN_VOLTAGEBreakdown Voltage (-999 if no breakdown occurred)floatTrueFalse-999
V_FULLDEPLDepletion Voltage (V)floatTrueFalse55.71
codeBAREMODULERECEPTION
nameBare module reception at ITk institute
order6
initialFalse
finalFalse
codeHPK
nameHamamatsu Photonics K.K (HPK)

 Current Stage: Parylene Unmasking

Past QC Stages and Results

Parylene Coating (MODULE/PARYLENE_COATING)

Parylene Masking (MODULE/PARYLENE_MASKING)

Initial Cold (MODULE/INITIAL_COLD)

QC cross-check (module swapping) (MODULE/QC_CROSSCHECK)

Initial Warm (MODULE/INITIAL_WARM)

Wire Bonding (MODULE/WIREBONDING)

Bare module to module PCB assembly (MODULE/ASSEMBLY)

Initial state to associate flex to bare module (MODULE/INIT)

Bare module reception at ITk institute (BAREMODULERECEPTION)

Test Local Result ProdDB Record
IV measurement
(IV_MEASURE)
Registered Registered

Bare Module Assembly (BAREMODULEASSEMBLY)

Not to be used for detector (NOT_USED)

Post Irradiation (POST_IRRAD)

Test Local Result ProdDB Record
CV measurement
(CV_MEASURE)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A

QA at Institutes (QA)

Test Local Result ProdDB Record
CV measurement
(CV_MEASURE)
No result N/A
Inter-pixel capacitance
(INTER-PIXEL_CAPACITANCE)
No result N/A
Inter-pixel resistance
(INTER-PIXEL_RESISTANCE)
No result N/A
IT measurement
(IT_MEASURE)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Sensor Metrology: Sensor bow and thickness
(SENSOR_METROLOGY)
No result N/A

Wafer Processing (dicing, UBM, flip-chip) (WAFER_PROCESSING)

Test Local Result ProdDB Record
CV measurement
(CV_MEASURE)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Sensor Metrology: Sensor bow and thickness
(SENSOR_METROLOGY)
No result N/A
Visual inspection
(VISUAL_INSPECTION)
No result N/A

Sensor Manufacturer (sensor_manufacturer)

Test Local Result ProdDB Record
CV measurement
(CV_MEASURE)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered
LocalDB Test ID Stage Test Name Inspector Measurement Date Analysis Date Tags QC Registration
68f5d8…9f0717 BAREMODULERECEPTION IV_MEASURE YujiEnari N/A 6 months ago No tags Selected
66f26c…264cc7 sensor_manufacturer IV_MEASURE KojiNakamura N/A a year ago No tags Selected
66f21c…7bd6c4 sensor_manufacturer CV_MEASURE KojiNakamura N/A a year ago No tags Selected
Stage Tests
sensor_manufacturer
  • CV measurement  (CV_MEASURE)
  • IV measurement  (IV_MEASURE)
WAFER_PROCESSING
  • Visual inspection  (VISUAL_INSPECTION)
  • Sensor Metrology: Sensor bow and thickness  (SENSOR_METROLOGY)
  • IV measurement  (IV_MEASURE)
  • CV measurement  (CV_MEASURE)
QA
  • CV measurement  (CV_MEASURE)
  • IV measurement  (IV_MEASURE)
  • IT measurement  (IT_MEASURE)
  • Inter-pixel capacitance  (INTER-PIXEL_CAPACITANCE)
  • Inter-pixel resistance  (INTER-PIXEL_RESISTANCE)
  • Sensor Metrology: Sensor bow and thickness  (SENSOR_METROLOGY)
POST_IRRAD
  • IV measurement  (IV_MEASURE)
  • CV measurement  (CV_MEASURE)
NOT_USED
BAREMODULEASSEMBLY
BAREMODULERECEPTION
  • IV measurement  (IV_MEASURE)
MODULE/INIT
MODULE/ASSEMBLY
MODULE/WIREBONDING
MODULE/INITIAL_WARM
MODULE/QC_CROSSCHECK
MODULE/INITIAL_COLD
MODULE/PARYLENE_MASKING
MODULE/PARYLENE_COATING
MODULE/PARYLENE_UNMASKING
MODULE/POST_PARYLENE_WARM
MODULE/POST_PARYLENE_COLD
MODULE/WIREBOND_PROTECTION
MODULE/THERMAL_CYCLES
MODULE/LONG_TERM_STABILITY_TEST
MODULE/FINAL_WARM
MODULE/FINAL_COLD
MODULE/FINAL_METROLOGY
MODULE/QC_STATUS
MODULE/UNHAPPY
MODULE/NOTCONSIDEREDINYIELDS
MODULE/GRAVEYARD
MODULE/COMPLETE
MODULE/RECEPTION
MODULE/TAB_CUTTING
LLS/PRE_TC_WARM
LLS/PRE_TC_COLD
LLS/POST_TC_WARM
LLS/POST_TC_COLD
LLS/RECEPTION
OB_LOADED_MODULE_CELL/INIT
OB_LOADED_MODULE_CELL/ASSEMBLY
OB_LOADED_MODULE_CELL/WIREBOND_PROTECTION
OB_LOADED_MODULE_CELL/THERMAL_CYCLES
OB_LOADED_MODULE_CELL/FINAL_WARM
OB_LOADED_MODULE_CELL/FINAL_COLD
OB_LOADED_MODULE_CELL/THERMAL_COLD
OB_LOADED_MODULE_CELL/THERMAL_WARM
OB_LOADED_MODULE_CELL/ENVELOPE_CHECK
OB_LOADED_MODULE_CELL/QC_STATUS
OB_LOADED_MODULE_CELL/UNHAPPY
OB_LOADED_MODULE_CELL/COMPLETE
OB_LOADED_MODULE_CELL/RECEPTION
OB_LOADED_MODULE_CELL/TAB_CUTTING
OB_LOADED_MODULE_CELL/PIGTAIL_INSERTION
Back to top page of this component