20UPGFC0142294

MODULE/POST_PARYLENE_COLD

Component Information

Serial Number 20UPGFC0142294
ProdDB ID  bbfb30…2fca21
LocalDB ID 660d7d122fc9f200350b6fdd
Component Type fe_chip
Parents 20UPGM2321003620UPGB43200197
Children No match.
Flags

 Properties

Item Value
Wafer serial number None
Target Iref trim None
Target Iref trim version None

 Comments


Test: MIN_HEALTH_TEST QC Passed

(Stage: MODULE/POST_PARYLENE_WARM)


Basic View Only: custom view for this TestRun is not prepared.

Metadata

Key Data
QC Passed True
Date 3 months ago
component ObjectId 660d7d122fc9f200350b6fdd
Stage MODULE/POST_PARYLENE_WARM
Test Type MIN_HEALTH_TEST
Institute ObjectId
User Name JonTaylor
ObjectId of this record 68b5be6b109cc5c44d7de2fa
ObjectId of RAW record None
Tags No tags

Results

Key Data
ANALYSIS_VERSION mqat v2.6.4
MEASUREMENT_DATE 2025-09-01T14:27:13.000+00:00
MEASUREMENT_DURATION 391
MEASUREMENT_VERSION None
YARR_VERSION v1.5.5
MIN_HEALTH_BAD_ANALOG 6
MIN_HEALTH_BAD_ANALOG_INTEGRATED 7
MIN_HEALTH_BAD_DIGITAL 0
MIN_HEALTH_COLUMN_DISABLED 0
MIN_HEALTH_DEAD_ANALOG 1
MIN_HEALTH_DEAD_DIGITAL 0
MIN_HEALTH_HIGH_ENC 2
MIN_HEALTH_HIGH_ENC_INDEPENDENT 2
MIN_HEALTH_NOISE_MEAN 116.54
MIN_HEALTH_NOISE_SIGMA 11.89
MIN_HEALTH_THRESHOLD_FAILED_FITS 6
MIN_HEALTH_THRESHOLD_FAILED_FITS_INDEPENDENT 13
MIN_HEALTH_THRESHOLD_MEAN 1501.26
MIN_HEALTH_THRESHOLD_SIGMA 38.04
MIN_HEALTH_TOT_MEAN 7.39
MIN_HEALTH_TOT_SIGMA 1.2

Attachments

Filename Contents
output.log Download
0x22bd6_THRESHOLD_MEAN_Threshold_1d.png
0x22bd6_HIGH_ENC_Noise_1d.png
0x22bd6.log Download
0x22bd6_MIN_HEALTH_TEST_depclassification.png
0x22bd6_MIN_HEALTH_TEST_indepclassification.png
0x22bd6_MHT_electrical_failures.png
0x22bd6_summary.png
20UPGFC0142294_MODULE__POST_PARYLENE_WARM_MIN-HEALTH-TEST.zip Download

ProductionDB Record

id68c2c1f01a8dab767bd32d1a
stateready
stateTs2025-09-11T12:34:56.300Z
stateUserIdentity24-7183-1
date2025-09-01T15:40:00.000Z
testType
id6393a08a15838700361eec84
codeMIN_HEALTH_TEST
nameMinimal Health Test
stateactive
institution
id59d60ee4ed67730005160cd9
codeGL
nameGlasgow University
user
id5d317963df98f2000973842f
userIdentity24-7183-1
firstNameJon
middleNameNone
lastNameTaylor
runNumber68b5be6b109cc5c44d7de2fa
passedTrue
problemsFalse
properties
codenamedataTypevalueTyperequiredvaluerangeMinrangeMax
ANALYSIS_VERSIONMin Health Test Analysis VersionstringNoneTrue2.6.4NoneNone
MEASUREMENT_DATEDate measurement performeddatetimeNoneFalse2025-09-01T14:27:13.000+00:00NoneNone
MEASUREMENT_DURATIONMeasurement durationintegerNoneFalse391NoneNone
MEASUREMENT_VERSIONMeasurement versionstringNoneFalseNoneNoneNone
YARR_VERSIONYarr VersionstringNoneFalsev1.5.5NoneNone
results
  • codeMIN_HEALTH_BAD_ANALOG
    nameNumber of bad pixels from analog scan
    dataTypeinteger
    valueTypesingle
    arrayDimensionsNone
    additionalNone
    rangeMinNone
    rangeMaxNone
    value6
    associateChildNone
  • codeMIN_HEALTH_BAD_ANALOG_INTEGRATED
    nameMIN_HEALTH_BAD_ANALOG_INTEGRATED
    order16
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value7
    associateChildNone
  • codeMIN_HEALTH_BAD_DIGITAL
    nameNumber of bad pixels from digital scan
    dataTypeinteger
    valueTypesingle
    arrayDimensionsNone
    additionalNone
    rangeMinNone
    rangeMaxNone
    value0
    associateChildNone
  • codeMIN_HEALTH_COLUMN_DISABLED
    nameNumber of pixels in disabled core columns
    order1
    dataTypeinteger
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value0
    associateChildNone
  • codeMIN_HEALTH_DEAD_ANALOG
    nameNumber of dead pixels from analog scan
    dataTypeinteger
    valueTypesingle
    arrayDimensionsNone
    additionalNone
    rangeMinNone
    rangeMaxNone
    value1
    associateChildNone
  • codeMIN_HEALTH_DEAD_DIGITAL
    nameNumber of dead pixels from digital scan
    dataTypeinteger
    valueTypesingle
    arrayDimensionsNone
    additionalNone
    rangeMinNone
    rangeMaxNone
    value0
    associateChildNone
  • codeMIN_HEALTH_HIGH_ENC
    nameNumber of pixels with High ENC
    dataTypeinteger
    valueTypesingle
    arrayDimensionsNone
    additionalNone
    rangeMinNone
    rangeMaxNone
    value2
    associateChildNone
  • codeMIN_HEALTH_HIGH_ENC_INDEPENDENT
    nameNumber of pixels with High ENC
    dataTypeinteger
    valueTypesingle
    arrayDimensionsNone
    additionalNone
    rangeMinNone
    rangeMaxNone
    value2
    associateChildNone
  • codeMIN_HEALTH_NOISE_MEAN
    nameNoise mean
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalNone
    rangeMinNone
    rangeMaxNone
    value116.54
    associateChildNone
  • codeMIN_HEALTH_NOISE_SIGMA
    nameNoise sigma
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalNone
    rangeMinNone
    rangeMaxNone
    value11.89
    associateChildNone
  • codeMIN_HEALTH_THRESHOLD_FAILED_FITS
    nameNumber of failed fits from threshold scan
    dataTypeinteger
    valueTypesingle
    arrayDimensionsNone
    additionalNone
    rangeMinNone
    rangeMaxNone
    value6
    associateChildNone
  • codeMIN_HEALTH_THRESHOLD_FAILED_FITS_INDEPENDENT
    nameNumber of failed fits from threshold scan
    dataTypeinteger
    valueTypesingle
    arrayDimensionsNone
    additionalNone
    rangeMinNone
    rangeMaxNone
    value13
    associateChildNone
  • codeMIN_HEALTH_THRESHOLD_MEAN
    nameMean of threshold distribution
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalNone
    rangeMinNone
    rangeMaxNone
    value1501.26
    associateChildNone
  • codeMIN_HEALTH_THRESHOLD_SIGMA
    nameSigma of threshold distribution
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalNone
    rangeMinNone
    rangeMaxNone
    value38.04
    associateChildNone
  • codeMIN_HEALTH_TOT_MEAN
    nameMean of ToT distribution
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalNone
    rangeMinNone
    rangeMaxNone
    value7.39
    associateChildNone
  • codeMIN_HEALTH_TOT_SIGMA
    nameSigma of ToT distribution
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalNone
    rangeMinNone
    rangeMaxNone
    value1.2
    associateChildNone
cts2025-09-11T12:34:56.300Z
sys
cts2025-09-11T12:34:56.300Z
mts2025-09-11T12:34:56.647Z
rev1
defects
commentsNone
attachments
codedateTimetitledescriptioncontentTypetypeurlurlCernboxfilenameuser
86469bfcbca54113c74b66b155a727bd2025-09-11T12:34:56.647ZTestRun_68c2c1f01a8dab767bd32d1a_Attachment_Pack.zip/home/pixeldaq/localdb3/localdb-tools/viewer/static/cache/thumbnail/TestRun_68c2c1f01a8dab767bd32d1a_Attachment_Pack.zipNoneeoshttps://eosatlas.cern.ch/eos/atlas/atlascerngroupdisk/det-itk/prod-db/8/6/4/86469bfcbca54113c74b66b155a727bd?authz=zteos64:MDAwMDAyYjR4nO1QvUrDUBglpUqpg6Jbpw_p4GCSe_PbfCDo6ugfSAh403vThra5IbldOjk6qM_g5FN0srSCiwguPoSvIMbi4ODo6BnOcDjncDjNWa2pFRs3l_eL1dZKqgY5365N8h3Nsk0hS5OpIfvmriiyXiHHOU_LgcmF0iu7mReS6zw2O6ZnOodtK-YJo9TRA5skOqUJ0ZkbV-TECaF-4PlWcPSshSdjAcciB-oB9ZEE6FCwiOVGME45Uod6HRou50TQ-1Js4oeTPAKVcpEpLKRUhktsx7XRsqxgP0RMKqBLDUo9I-gYlESQsZHAZQ3wDKEaq3BQxC6wPEfoy1Lh70EuRyzN8IfSExKhHHOJBFTBugJBZrHos2GCm_Awn38UZ41472Lxvr5bv348n269tvna6dNB467-9tL6__kPfoar2-lM-wRpWNYShttps://cernbox.cern.ch/files/spaces/eos/atlas/atlascerngroupdisk/det-itk/prod-db/8/6/4/86469bfcbca54113c74b66b155a727bd86469bfcbca54113c74b66b155a727bd
id5d317963df98f2000973842f
userIdentity24-7183-1
firstNameJon
middleNameNone
lastNameTaylor
components
idcodestatestateTsstateUserIdentitydummycompletedcompletedTscompletedUserIdentitytrashedtrashedTstrashedUserIdentityserialNumberalternativeIdentifierancestorMapprojectsubprojectcomponentTypetypepropertiestestedAtStageinstitution
660d7d122fc9f200350b6fddbbfb307d5a702fde430ad32ca22fca21ready2024-04-03T16:00:18.717Z5310-2637-1FalseFalseNoneNoneFalseNoneNone20UPGFC0142294None
parent
component
id67c71488d89b87c79a24155e
codeb59c2d7aed9ac19d895078de74350692
stateready
stateTs2025-03-04T14:56:08.664Z
stateUserIdentity23-6780-1
dummyFalse
completedFalse
completedTsNone
completedUserIdentityNone
trashedFalse
trashedTsNone
trashedUserIdentityNone
serialNumber20UPGB43200197
alternativeIdentifierNone
project
codeP
namePixels
subproject
codePG
namePixel general
componentType
codeBARE_MODULE
nameBare Module
type
codeQUAD_BARE_MODULE
nameQuad bare module
testedAtStage
codeMODULE/FINAL_COLD
nameFinal Cold
highestLevelParent
component
id67e4041c38d08a4ce78bc5e4
codebc4e17b6986f011e5426162b1701bef1
stateready
stateTs2025-03-26T13:41:48.509Z
stateUserIdentity7075-9969-1
dummyFalse
completedFalse
completedTsNone
completedUserIdentityNone
trashedFalse
trashedTsNone
trashedUserIdentityNone
serialNumber20UPGM23210036
alternativeIdentifierNone
project
codeP
namePixels
subproject
codePG
namePixel general
componentType
codeMODULE
nameModule
type
codeOUTER_SYSTEM_QUAD_MODULE
nameOuter system quad module
testedAtStage
codeMODULE/FINAL_COLD
nameFinal Cold
codeP
namePixels
codePG
namePixel general
codeFE_CHIP
nameFront-end Chip
codeITKPIX_V2
nameITkpix_V2
None
codeMODULE/POST_PARYLENE_WARM
namePost-Parylene Warm
order15
initialFalse
finalFalse
codeGL
nameGlasgow University

 Current Stage: Post-Parylene Cold

Test Type Local Result
ADC Calibration
(ADC_CALIBRATION)
No TestRun!
Analog Readback
(ANALOG_READBACK)
No TestRun!
VCAL Calibration
(VCAL_CALIBRATION)
No TestRun!
Low Power Mode
(LP_MODE)
No TestRun!
Data Transmission
(DATA_TRANSMISSION)
No TestRun!
Overvoltage Protection
(OVERVOLTAGE_PROTECTION)
No TestRun!
Undershunt Protection
(UNDERSHUNT_PROTECTION)
No TestRun!
SLDO
(SLDO)
No TestRun!
Minimal Health Test
(MIN_HEALTH_TEST)
No TestRun!
Tuning
(TUNING)
No TestRun!
Pixel Failure Analysis
(PIXEL_FAILURE_ANALYSIS)
No TestRun!
Injection Capacitance
(INJECTION_CAPACITANCE)
No TestRun!

 Candidate TestRuns of this Stage

LDB ID TestRun Code QC Passed Inspector Measurement Date Analysis Date Analysis Version Tags QC Registration
68b5ba…7de26b LP_MODE Pass JonTaylor 3 months ago 3 months ago 2.6.4 No tags Selected
68b5c5…7de4a5 PIXEL_FAILURE_ANALYSIS Pass JonTaylor N/A 3 months ago 2.6.4 No tags Selected
68b5c5…7de3b5 TUNING Pass JonTaylor N/A 3 months ago 2.6.4 No tags Selected
68b5be…7de2fa MIN_HEALTH_TEST Pass JonTaylor N/A 3 months ago 2.6.4 No tags Selected
68b5ba…7de240 INJECTION_CAPACITANCE Pass JonTaylor 3 months ago 3 months ago 2.6.4 No tags Selected
68b5bb…7de2a4 DATA_TRANSMISSION Pass JonTaylor 3 months ago 3 months ago 2.6.4 No tags Selected
68b5b9…7de1f0 VCAL_CALIBRATION Pass JonTaylor 3 months ago 3 months ago 2.6.4 No tags Selected
68b5b7…7de190 SLDO Pass JonTaylor 3 months ago 3 months ago 2.6.4 No tags Selected
68b5b0…7de140 ANALOG_READBACK Pass JonTaylor 3 months ago 3 months ago 2.6.4 No tags Selected
68b5a0…7de090 ADC_CALIBRATION Pass JonTaylor 3 months ago 3 months ago 2.6.4 No tags Selected

Past QC Stages and Results

Post-Parylene Warm (MODULE/POST_PARYLENE_WARM)

Test Local Result ProdDB Record
ADC Calibration
(ADC_CALIBRATION)
Registered Registered
Analog Readback
(ANALOG_READBACK)
Registered Registered
Data Transmission
(DATA_TRANSMISSION)
Registered Registered
Injection Capacitance
(INJECTION_CAPACITANCE)
Registered Registered
Low Power Mode
(LP_MODE)
Registered Registered
Minimal Health Test
(MIN_HEALTH_TEST)
Registered Registered
Overvoltage Protection
(OVERVOLTAGE_PROTECTION)
No result N/A
Pixel Failure Analysis
(PIXEL_FAILURE_ANALYSIS)
Registered Registered
SLDO
(SLDO)
Registered Registered
Tuning
(TUNING)
Registered Registered
Undershunt Protection
(UNDERSHUNT_PROTECTION)
No result N/A
VCAL Calibration
(VCAL_CALIBRATION)
Registered Registered

Wirebond Protection (alt) (MODULE/WIREBOND_PROTECTION)

Test Local Result ProdDB Record
Minimal Health Test
(MIN_HEALTH_TEST)
No result N/A
Pixel Failure Analysis
(PIXEL_FAILURE_ANALYSIS)
No result N/A
Tuning
(TUNING)
No result N/A

Parylene Unmasking (MODULE/PARYLENE_UNMASKING)

Test Local Result ProdDB Record
Minimal Health Test
(MIN_HEALTH_TEST)
No result N/A
Pixel Failure Analysis
(PIXEL_FAILURE_ANALYSIS)
No result N/A
Tuning
(TUNING)
No result N/A

Parylene Coating (MODULE/PARYLENE_COATING)

Parylene Masking (MODULE/PARYLENE_MASKING)

Initial Cold (MODULE/INITIAL_COLD)

Test Local Result ProdDB Record
ADC Calibration
(ADC_CALIBRATION)
No result N/A
Analog Readback
(ANALOG_READBACK)
No result N/A
Data Transmission
(DATA_TRANSMISSION)
No result N/A
Injection Capacitance
(INJECTION_CAPACITANCE)
No result N/A
Low Power Mode
(LP_MODE)
No result N/A
Minimal Health Test
(MIN_HEALTH_TEST)
No result N/A
Overvoltage Protection
(OVERVOLTAGE_PROTECTION)
No result N/A
Pixel Failure Analysis
(PIXEL_FAILURE_ANALYSIS)
No result N/A
SLDO
(SLDO)
No result N/A
Tuning
(TUNING)
No result N/A
Undershunt Protection
(UNDERSHUNT_PROTECTION)
No result N/A
VCAL Calibration
(VCAL_CALIBRATION)
No result N/A

QC cross-check (module swapping) (MODULE/QC_CROSSCHECK)

Test Local Result ProdDB Record
ADC Calibration
(ADC_CALIBRATION)
No result N/A
Analog Readback
(ANALOG_READBACK)
No result N/A
Data Transmission
(DATA_TRANSMISSION)
No result N/A
Injection Capacitance
(INJECTION_CAPACITANCE)
No result N/A
Low Power Mode
(LP_MODE)
No result N/A
Minimal Health Test
(MIN_HEALTH_TEST)
No result N/A
Overvoltage Protection
(OVERVOLTAGE_PROTECTION)
No result N/A
Pixel Failure Analysis
(PIXEL_FAILURE_ANALYSIS)
No result N/A
SLDO
(SLDO)
No result N/A
Tuning
(TUNING)
No result N/A
Undershunt Protection
(UNDERSHUNT_PROTECTION)
No result N/A
VCAL Calibration
(VCAL_CALIBRATION)
No result N/A

Initial Warm (MODULE/INITIAL_WARM)

Test Local Result ProdDB Record
ADC Calibration
(ADC_CALIBRATION)
Registered Registered
Analog Readback
(ANALOG_READBACK)
Registered Registered
Data Transmission
(DATA_TRANSMISSION)
Registered Registered
Injection Capacitance
(INJECTION_CAPACITANCE)
Registered Registered
Low Power Mode
(LP_MODE)
Registered Registered
Minimal Health Test
(MIN_HEALTH_TEST)
Registered Registered
Overvoltage Protection
(OVERVOLTAGE_PROTECTION)
No result N/A
Pixel Failure Analysis
(PIXEL_FAILURE_ANALYSIS)
Registered Registered
SLDO
(SLDO)
Registered Registered
Tuning
(TUNING)
Registered Registered
Undershunt Protection
(UNDERSHUNT_PROTECTION)
No result N/A
VCAL Calibration
(VCAL_CALIBRATION)
Registered Registered

Wire Bonding (MODULE/WIREBONDING)

Bare module to module PCB assembly (MODULE/ASSEMBLY)

Initial state to associate flex to bare module (MODULE/INIT)

Reception at ITk institute (BAREMODULERECEPTION)

Test Local Result ProdDB Record
Analog Readback
(ANALOG_READBACK)
No result N/A
Minimal Health Test
(MIN_HEALTH_TEST)
No result N/A

Bare module assembly (BAREMODULEASSEMBLY)

Not to be used for detector (UNUSABLE)

Hybridisation (HYBRIDISATION)

Testing on wafer (TESTONWAFER)

Test Local Result ProdDB Record
Electrical FE chip tests
(FECHIP_TEST)
Registered Registered
LocalDB Test ID Stage Test Name Inspector Measurement Date Analysis Date Tags QC Registration
68b5ba…7de26b MODULE/POST_PARYLENE_WARM LP_MODE JonTaylor 3 months ago 3 months ago No tags Selected
68b5c5…7de4a5 MODULE/POST_PARYLENE_WARM PIXEL_FAILURE_ANALYSIS JonTaylor N/A 3 months ago No tags Selected
68b5c5…7de3b5 MODULE/POST_PARYLENE_WARM TUNING JonTaylor N/A 3 months ago No tags Selected
68b5be…7de2fa MODULE/POST_PARYLENE_WARM MIN_HEALTH_TEST JonTaylor N/A 3 months ago No tags Selected
68b5ba…7de240 MODULE/POST_PARYLENE_WARM INJECTION_CAPACITANCE JonTaylor 3 months ago 3 months ago No tags Selected
68b5bb…7de2a4 MODULE/POST_PARYLENE_WARM DATA_TRANSMISSION JonTaylor 3 months ago 3 months ago No tags Selected
68b5b9…7de1f0 MODULE/POST_PARYLENE_WARM VCAL_CALIBRATION JonTaylor 3 months ago 3 months ago No tags Selected
68b5b7…7de190 MODULE/POST_PARYLENE_WARM SLDO JonTaylor 3 months ago 3 months ago No tags Selected
68b5b0…7de140 MODULE/POST_PARYLENE_WARM ANALOG_READBACK JonTaylor 3 months ago 3 months ago No tags Selected
68b5a0…7de090 MODULE/POST_PARYLENE_WARM ADC_CALIBRATION JonTaylor 3 months ago 3 months ago No tags Selected
68c02e…b2987e MODULE/FINAL_COLD DATA_TRANSMISSION Md ArifAbdullaSamy 3 months ago 3 months ago No tags Selected
68c04a…b29e65 MODULE/FINAL_COLD PIXEL_FAILURE_ANALYSIS Md ArifAbdullaSamy N/A 3 months ago No tags Selected
68c031…b29b4f MODULE/FINAL_COLD MIN_HEALTH_TEST Md ArifAbdullaSamy N/A 3 months ago No tags Selected
68c034…b29c22 MODULE/FINAL_COLD TUNING Md ArifAbdullaSamy N/A 3 months ago No tags Selected
68c02e…b29854 MODULE/FINAL_COLD LP_MODE Md ArifAbdullaSamy 3 months ago 3 months ago No tags Selected
68c02d…b29830 MODULE/FINAL_COLD INJECTION_CAPACITANCE Md ArifAbdullaSamy 3 months ago 3 months ago No tags Selected
68c02d…b297fc MODULE/FINAL_COLD VCAL_CALIBRATION Md ArifAbdullaSamy 3 months ago 3 months ago No tags Selected
68c02c…b297b8 MODULE/FINAL_COLD SLDO Md ArifAbdullaSamy 3 months ago 3 months ago No tags Selected
68c020…b294db MODULE/FINAL_COLD ANALOG_READBACK Md ArifAbdullaSamy 3 months ago 3 months ago No tags Selected
68c015…b292a2 MODULE/FINAL_COLD ADC_CALIBRATION Md ArifAbdullaSamy 3 months ago 3 months ago No tags Selected
68c008…b220b3 MODULE/FINAL_WARM INJECTION_CAPACITANCE Md ArifAbdullaSamy 3 months ago 3 months ago No tags Selected
68c008…b220de MODULE/FINAL_WARM LP_MODE Md ArifAbdullaSamy 3 months ago 3 months ago No tags Selected
68c00f…b23d91 MODULE/FINAL_WARM TUNING Md ArifAbdullaSamy N/A 3 months ago No tags Selected
68c011…b29139 MODULE/FINAL_WARM PIXEL_FAILURE_ANALYSIS Md ArifAbdullaSamy N/A 3 months ago No tags Selected
68c00e…b23c5a MODULE/FINAL_WARM MIN_HEALTH_TEST Md ArifAbdullaSamy N/A 3 months ago No tags Selected
68c009…b22117 MODULE/FINAL_WARM DATA_TRANSMISSION Md ArifAbdullaSamy 3 months ago 3 months ago No tags Selected
68c008…b22063 MODULE/FINAL_WARM VCAL_CALIBRATION Md ArifAbdullaSamy 3 months ago 3 months ago No tags Selected
68c007…b22003 MODULE/FINAL_WARM SLDO Md ArifAbdullaSamy 3 months ago 3 months ago No tags Selected
68bff7…b21c3b MODULE/FINAL_WARM ANALOG_READBACK Md ArifAbdullaSamy 3 months ago 3 months ago No tags Selected
68bfec…b1ad99 MODULE/FINAL_WARM ADC_CALIBRATION Md ArifAbdullaSamy 3 months ago 3 months ago No tags Selected
684b4b…bf3184 MODULE/INITIAL_WARM PIXEL_FAILURE_ANALYSIS JonTaylor N/A 6 months ago No tags Selected
684b49…bf3058 MODULE/INITIAL_WARM TUNING JonTaylor N/A 6 months ago No tags Selected
684b41…bf3018 MODULE/INITIAL_WARM MIN_HEALTH_TEST JonTaylor N/A 6 months ago No tags Selected
684b2c…bf2f65 MODULE/INITIAL_WARM INJECTION_CAPACITANCE JonTaylor 6 months ago 6 months ago No tags Selected
684b30…bf2fad MODULE/INITIAL_WARM DATA_TRANSMISSION JonTaylor 6 months ago 6 months ago No tags Selected
684b2f…bf2f89 MODULE/INITIAL_WARM LP_MODE JonTaylor 6 months ago 6 months ago No tags Selected
684b2b…bf2f31 MODULE/INITIAL_WARM VCAL_CALIBRATION JonTaylor 6 months ago 6 months ago No tags Selected
684b29…bf2eed MODULE/INITIAL_WARM SLDO JonTaylor 6 months ago 6 months ago No tags Selected
684b22…bf2eb9 MODULE/INITIAL_WARM ANALOG_READBACK JonTaylor 6 months ago 6 months ago No tags Selected
684b13…bf2e09 MODULE/INITIAL_WARM ADC_CALIBRATION JonTaylor 6 months ago 6 months ago No tags Selected
660d7e…453252 TESTONWAFER FECHIP_TEST DimaManeuski N/A a year ago No tags Selected

Stage: MODULE/POST_PARYLENE_COLD

Mode: warm
Index Revision ID Timestamp Message
HEAD 68c9...48cfd7 3 months ago downloaded from ITkPD : code = 902fba8741215c6e356e41c278544c6a, description = {"_id":"68b57f34109cc5c44d7de040","serialNumber":"20UPGFC0142294","stage":"MODULE/POST_PARYLENE_WARM","branch":"warm","current_revision_id":"68b5c23f0d5ca2e484e8bed9"}
Mode: cold
Index Revision ID Timestamp Message
HEAD 68c9...48cfe0 3 months ago downloaded from ITkPD : code = 893c3c721f987f611125bab7e8e0bb32, description = {"_id":"68c01222dcbb9b92e8b291fc","serialNumber":"20UPGFC0142294","stage":"MODULE/FINAL_COLD","branch":"cold","current_revision_id":"68c047a8646b2da74849b284"}
Mode: LP
Index Revision ID Timestamp Message
HEAD 68c9...48cfe2 3 months ago downloaded from ITkPD : code = 8aa2307ed6445930dc70975b037e68aa, description = {"_id":"684add41f23308c13dbf2dd4","serialNumber":"20UPGFC0142294","stage":"MODULE/INITIAL_WARM","branch":"LP","current_revision_id":"684b2fb5f23308c13dbf2f8a"}
Stage Tests
TESTONWAFER
  • Electrical FE chip tests   (FECHIP_TEST)
HYBRIDISATION
UNUSABLE
BAREMODULEASSEMBLY
BAREMODULERECEPTION
  • Minimal Health Test  (MIN_HEALTH_TEST)
  • Analog Readback  (ANALOG_READBACK)
MODULE/INIT
MODULE/ASSEMBLY
MODULE/WIREBONDING
  • ADC Calibration  (ADC_CALIBRATION)
  • Data Transmission  (DATA_TRANSMISSION)
  • VCAL Calibration  (VCAL_CALIBRATION)
  • Minimal Health Test  (MIN_HEALTH_TEST)
  • Tuning  (TUNING)
  • Pixel Failure Analysis  (PIXEL_FAILURE_ANALYSIS)
  • SLDO  (SLDO)
  • Low Power Mode  (LP_MODE)
  • Analog Readback  (ANALOG_READBACK)
  • Injection Capacitance  (INJECTION_CAPACITANCE)
MODULE/INITIAL_WARM
  • ADC Calibration  (ADC_CALIBRATION)
  • Analog Readback  (ANALOG_READBACK)
  • SLDO  (SLDO)
  • VCAL Calibration  (VCAL_CALIBRATION)
  • Low Power Mode  (LP_MODE)
  • Overvoltage Protection  (OVERVOLTAGE_PROTECTION)
  • Undershunt Protection  (UNDERSHUNT_PROTECTION)
  • Data Transmission  (DATA_TRANSMISSION)
  • Injection Capacitance  (INJECTION_CAPACITANCE)
  • Minimal Health Test  (MIN_HEALTH_TEST)
  • Tuning  (TUNING)
  • Pixel Failure Analysis  (PIXEL_FAILURE_ANALYSIS)
MODULE/QC_CROSSCHECK
  • ADC Calibration  (ADC_CALIBRATION)
  • Analog Readback  (ANALOG_READBACK)
  • SLDO  (SLDO)
  • VCAL Calibration  (VCAL_CALIBRATION)
  • Low Power Mode  (LP_MODE)
  • Overvoltage Protection  (OVERVOLTAGE_PROTECTION)
  • Undershunt Protection  (UNDERSHUNT_PROTECTION)
  • Data Transmission  (DATA_TRANSMISSION)
  • Injection Capacitance  (INJECTION_CAPACITANCE)
  • Minimal Health Test  (MIN_HEALTH_TEST)
  • Tuning  (TUNING)
  • Pixel Failure Analysis  (PIXEL_FAILURE_ANALYSIS)
MODULE/INITIAL_COLD
  • ADC Calibration  (ADC_CALIBRATION)
  • Analog Readback  (ANALOG_READBACK)
  • SLDO  (SLDO)
  • VCAL Calibration  (VCAL_CALIBRATION)
  • Injection Capacitance  (INJECTION_CAPACITANCE)
  • Tuning  (TUNING)
  • Minimal Health Test  (MIN_HEALTH_TEST)
  • Pixel Failure Analysis  (PIXEL_FAILURE_ANALYSIS)
  • Low Power Mode  (LP_MODE)
  • Overvoltage Protection  (OVERVOLTAGE_PROTECTION)
  • Undershunt Protection  (UNDERSHUNT_PROTECTION)
  • Data Transmission  (DATA_TRANSMISSION)
MODULE/PARYLENE_MASKING
  • ADC Calibration  (ADC_CALIBRATION)
  • VCAL Calibration  (VCAL_CALIBRATION)
  • SLDO  (SLDO)
  • Low Power Mode  (LP_MODE)
  • Minimal Health Test  (MIN_HEALTH_TEST)
  • Tuning  (TUNING)
  • Pixel Failure Analysis  (PIXEL_FAILURE_ANALYSIS)
  • Analog Readback  (ANALOG_READBACK)
  • Injection Capacitance  (INJECTION_CAPACITANCE)
  • Data Transmission  (DATA_TRANSMISSION)
MODULE/PARYLENE_COATING
MODULE/PARYLENE_UNMASKING
  • Minimal Health Test  (MIN_HEALTH_TEST)
  • Pixel Failure Analysis  (PIXEL_FAILURE_ANALYSIS)
  • Tuning  (TUNING)
  • Data Transmission  (DATA_TRANSMISSION)
  • ADC Calibration  (ADC_CALIBRATION)
  • VCAL Calibration  (VCAL_CALIBRATION)
  • SLDO  (SLDO)
  • Analog Readback  (ANALOG_READBACK)
  • Injection Capacitance  (INJECTION_CAPACITANCE)
  • Low Power Mode  (LP_MODE)
MODULE/WIREBOND_PROTECTION
  • Minimal Health Test  (MIN_HEALTH_TEST)
  • Pixel Failure Analysis  (PIXEL_FAILURE_ANALYSIS)
  • Tuning  (TUNING)
  • ADC Calibration  (ADC_CALIBRATION)
  • Low Power Mode  (LP_MODE)
  • VCAL Calibration  (VCAL_CALIBRATION)
  • Analog Readback  (ANALOG_READBACK)
  • Injection Capacitance  (INJECTION_CAPACITANCE)
  • SLDO  (SLDO)
  • Data Transmission  (DATA_TRANSMISSION)
MODULE/POST_PARYLENE_WARM
  • ADC Calibration  (ADC_CALIBRATION)
  • Analog Readback  (ANALOG_READBACK)
  • Overvoltage Protection  (OVERVOLTAGE_PROTECTION)
  • Undershunt Protection  (UNDERSHUNT_PROTECTION)
  • SLDO  (SLDO)
  • VCAL Calibration  (VCAL_CALIBRATION)
  • Data Transmission  (DATA_TRANSMISSION)
  • Injection Capacitance  (INJECTION_CAPACITANCE)
  • Minimal Health Test  (MIN_HEALTH_TEST)
  • Tuning  (TUNING)
  • Pixel Failure Analysis  (PIXEL_FAILURE_ANALYSIS)
  • Low Power Mode  (LP_MODE)
MODULE/POST_PARYLENE_COLD
  • ADC Calibration  (ADC_CALIBRATION)
  • Analog Readback  (ANALOG_READBACK)
  • VCAL Calibration  (VCAL_CALIBRATION)
  • Low Power Mode  (LP_MODE)
  • Data Transmission  (DATA_TRANSMISSION)
  • Overvoltage Protection  (OVERVOLTAGE_PROTECTION)
  • Undershunt Protection  (UNDERSHUNT_PROTECTION)
  • SLDO  (SLDO)
  • Minimal Health Test  (MIN_HEALTH_TEST)
  • Tuning  (TUNING)
  • Pixel Failure Analysis  (PIXEL_FAILURE_ANALYSIS)
  • Injection Capacitance  (INJECTION_CAPACITANCE)
MODULE/THERMAL_CYCLES
  • Minimal Health Test  (MIN_HEALTH_TEST)
  • Pixel Failure Analysis  (PIXEL_FAILURE_ANALYSIS)
  • Tuning  (TUNING)
  • Data Transmission  (DATA_TRANSMISSION)
  • SLDO  (SLDO)
  • ADC Calibration  (ADC_CALIBRATION)
  • VCAL Calibration  (VCAL_CALIBRATION)
  • Analog Readback  (ANALOG_READBACK)
  • Injection Capacitance  (INJECTION_CAPACITANCE)
  • Low Power Mode  (LP_MODE)
  • Cold startup  (COLD_STARTUP)
MODULE/LONG_TERM_STABILITY_TEST
  • Minimal Health Test  (MIN_HEALTH_TEST)
  • Pixel Failure Analysis  (PIXEL_FAILURE_ANALYSIS)
  • Low Power Mode  (LP_MODE)
  • Data Transmission  (DATA_TRANSMISSION)
  • SLDO  (SLDO)
  • Tuning  (TUNING)
  • ADC Calibration  (ADC_CALIBRATION)
  • VCAL Calibration  (VCAL_CALIBRATION)
  • Analog Readback  (ANALOG_READBACK)
  • Injection Capacitance  (INJECTION_CAPACITANCE)
MODULE/FINAL_WARM
  • ADC Calibration  (ADC_CALIBRATION)
  • Analog Readback  (ANALOG_READBACK)
  • SLDO  (SLDO)
  • VCAL Calibration  (VCAL_CALIBRATION)
  • Undershunt Protection  (UNDERSHUNT_PROTECTION)
  • Overvoltage Protection  (OVERVOLTAGE_PROTECTION)
  • Data Transmission  (DATA_TRANSMISSION)
  • Minimal Health Test  (MIN_HEALTH_TEST)
  • Pixel Failure Analysis  (PIXEL_FAILURE_ANALYSIS)
  • Tuning  (TUNING)
  • Low Power Mode  (LP_MODE)
  • Injection Capacitance  (INJECTION_CAPACITANCE)
MODULE/FINAL_COLD
  • ADC Calibration  (ADC_CALIBRATION)
  • Analog Readback  (ANALOG_READBACK)
  • SLDO  (SLDO)
  • VCAL Calibration  (VCAL_CALIBRATION)
  • Injection Capacitance  (INJECTION_CAPACITANCE)
  • Low Power Mode  (LP_MODE)
  • Overvoltage Protection  (OVERVOLTAGE_PROTECTION)
  • Undershunt Protection  (UNDERSHUNT_PROTECTION)
  • Tuning  (TUNING)
  • Minimal Health Test  (MIN_HEALTH_TEST)
  • Pixel Failure Analysis  (PIXEL_FAILURE_ANALYSIS)
  • Data Transmission  (DATA_TRANSMISSION)
  • Cold startup  (COLD_STARTUP)
MODULE/FINAL_METROLOGY
  • Data Transmission  (DATA_TRANSMISSION)
  • ADC Calibration  (ADC_CALIBRATION)
  • VCAL Calibration  (VCAL_CALIBRATION)
  • SLDO  (SLDO)
  • Injection Capacitance  (INJECTION_CAPACITANCE)
  • Minimal Health Test  (MIN_HEALTH_TEST)
  • Tuning  (TUNING)
  • Pixel Failure Analysis  (PIXEL_FAILURE_ANALYSIS)
  • Injection Capacitance  (INJECTION_CAPACITANCE)
  • Analog Readback  (ANALOG_READBACK)
MODULE/QC_STATUS
MODULE/UNHAPPY
  • ADC Calibration  (ADC_CALIBRATION)
  • Analog Readback  (ANALOG_READBACK)
  • Data Transmission  (DATA_TRANSMISSION)
  • VCAL Calibration  (VCAL_CALIBRATION)
  • Minimal Health Test  (MIN_HEALTH_TEST)
  • Tuning  (TUNING)
  • Pixel Failure Analysis  (PIXEL_FAILURE_ANALYSIS)
  • Low Power Mode  (LP_MODE)
  • Data Transmission  (DATA_TRANSMISSION)
  • Injection Capacitance  (INJECTION_CAPACITANCE)
MODULE/NOTCONSIDEREDINYIELDS
  • ADC Calibration  (ADC_CALIBRATION)
  • VCAL Calibration  (VCAL_CALIBRATION)
  • SLDO  (SLDO)
  • Undershunt Protection  (UNDERSHUNT_PROTECTION)
  • Pixel Failure Analysis  (PIXEL_FAILURE_ANALYSIS)
  • Minimal Health Test  (MIN_HEALTH_TEST)
  • Tuning  (TUNING)
  • Analog Readback  (ANALOG_READBACK)
  • Overvoltage Protection  (OVERVOLTAGE_PROTECTION)
  • Low Power Mode  (LP_MODE)
  • Injection Capacitance  (INJECTION_CAPACITANCE)
  • Data Transmission  (DATA_TRANSMISSION)
MODULE/GRAVEYARD
MODULE/COMPLETE
MODULE/RECEPTION
  • Minimal Health Test  (MIN_HEALTH_TEST)
  • Pixel Failure Analysis  (PIXEL_FAILURE_ANALYSIS)
  • ADC Calibration  (ADC_CALIBRATION)
  • Analog Readback  (ANALOG_READBACK)
  • SLDO  (SLDO)
  • Data Transmission  (DATA_TRANSMISSION)
  • Tuning  (TUNING)
MODULE/TAB_CUTTING
  • Minimal Health Test  (MIN_HEALTH_TEST)
LLS/PRE_TC_WARM
  • Minimal Health Test  (MIN_HEALTH_TEST)
  • Analog Readback  (ANALOG_READBACK)
  • SLDO  (SLDO)
  • Low Power Mode  (LP_MODE)
  • Tuning  (TUNING)
  • Pixel Failure Analysis  (PIXEL_FAILURE_ANALYSIS)
LLS/PRE_TC_COLD
  • Minimal Health Test  (MIN_HEALTH_TEST)
  • Analog Readback  (ANALOG_READBACK)
  • SLDO  (SLDO)
  • Tuning  (TUNING)
  • Pixel Failure Analysis  (PIXEL_FAILURE_ANALYSIS)
LLS/POST_TC_WARM
  • Minimal Health Test  (MIN_HEALTH_TEST)
  • Analog Readback  (ANALOG_READBACK)
  • SLDO  (SLDO)
  • Tuning  (TUNING)
  • Pixel Failure Analysis  (PIXEL_FAILURE_ANALYSIS)
LLS/POST_TC_COLD
  • Minimal Health Test  (MIN_HEALTH_TEST)
  • Analog Readback  (ANALOG_READBACK)
  • SLDO  (SLDO)
  • Tuning  (TUNING)
  • Pixel Failure Analysis  (PIXEL_FAILURE_ANALYSIS)
LLS/RECEPTION
  • Minimal Health Test  (MIN_HEALTH_TEST)
  • Analog Readback  (ANALOG_READBACK)
  • SLDO  (SLDO)
  • Tuning  (TUNING)
  • Pixel Failure Analysis  (PIXEL_FAILURE_ANALYSIS)
OB_LOADED_MODULE_CELL/INIT
OB_LOADED_MODULE_CELL/ASSEMBLY
OB_LOADED_MODULE_CELL/THERMAL_CYCLES
OB_LOADED_MODULE_CELL/FINAL_WARM
  • ADC Calibration  (ADC_CALIBRATION)
  • Analog Readback  (ANALOG_READBACK)
  • SLDO  (SLDO)
  • VCAL Calibration  (VCAL_CALIBRATION)
  • Injection Capacitance  (INJECTION_CAPACITANCE)
  • Low Power Mode  (LP_MODE)
  • Data Transmission  (DATA_TRANSMISSION)
  • Minimal Health Test  (MIN_HEALTH_TEST)
  • Tuning  (TUNING)
  • Pixel Failure Analysis  (PIXEL_FAILURE_ANALYSIS)
OB_LOADED_MODULE_CELL/FINAL_COLD
  • ADC Calibration  (ADC_CALIBRATION)
  • Analog Readback  (ANALOG_READBACK)
  • SLDO  (SLDO)
  • VCAL Calibration  (VCAL_CALIBRATION)
  • Injection Capacitance  (INJECTION_CAPACITANCE)
  • Low Power Mode  (LP_MODE)
  • Data Transmission  (DATA_TRANSMISSION)
  • Minimal Health Test  (MIN_HEALTH_TEST)
  • Tuning  (TUNING)
  • Pixel Failure Analysis  (PIXEL_FAILURE_ANALYSIS)
OB_LOADED_MODULE_CELL/THERMAL_COLD
OB_LOADED_MODULE_CELL/THERMAL_WARM
OB_LOADED_MODULE_CELL/ENVELOPE_CHECK
OB_LOADED_MODULE_CELL/QC_STATUS
OB_LOADED_MODULE_CELL/UNHAPPY
OB_LOADED_MODULE_CELL/COMPLETE
OB_LOADED_MODULE_CELL/RECEPTION
  • Minimal Health Test  (MIN_HEALTH_TEST)
  • Pixel Failure Analysis  (PIXEL_FAILURE_ANALYSIS)
  • SLDO  (SLDO)
OB_LOADED_MODULE_CELL/TAB_CUTTING
  • Minimal Health Test  (MIN_HEALTH_TEST)
OB_LOADED_MODULE_CELL/PIGTAIL_INSERTION
TEST_AFTER_LOADED_LOCAL_SUPPORT_ASSEMBLY
  • OB:Loaded local support QC electrical connectivity  (OBLoadedLocalSupportQC_ElectricalConnectivity)
  • OB:Loaded local support QC electrical performance  (OBLoadedLocalSupportQC_ElectricalPerformance)
  • OB:Loaded local support reception at the integration site  (OBLoadedLocalSupport_IntegrationSite)
  • OB:Loaded local support QC electrical low power  (OBLoadedLocalSupport_QCElectricalLowPower)
TEST_JM_OEC_FE
Back to top page of this component