20UPIMS2102148

MODULE/FINAL_METROLOGY

Component Information

Serial Number 20UPIMS2102148
ProdDB ID  635d48…faff81
LocalDB ID 66729817ead3ed0035c9e5e3
Component Type MODULE
Parents No match.
Children 20UPGB12200068 Bare Module 20UPGB12200083 Bare Module 20UPGB12200053 Bare Module 20UPGFC0096201 FE Chip 20UPGFC0096088 FE Chip 20UPIPT3272148 PCB 20UPGFC0096069 FE Chip
Flags
Distribution of chips on wafer

 Properties

Item Value
PCB-Bare Orientation isNormal False
FE chip version 2
Wirebond protection roof presence False
IREFTRIM_FE1 deleted 14
IREFTRIM_FE2 deleted 9
IREFTRIM_FE3 deleted 9
IREFTRIM_FE4 deleted None
Alternative ID None
Rank None

 Comments

 Current Stage: Final flatness measurement

Test Type Local Result
Flatness
(FLATNESS)
No TestRun!

 Candidate TestRuns of this Stage

LDB ID TestRun Code QC Passed Inspector Measurement Date Analysis Date Analysis Version Tags QC Registration

Past QC Stages and Results

Final Cold (MODULE/FINAL_COLD)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Final Warm (MODULE/FINAL_WARM)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Long Term Stability Test (MODULE/LONG_TERM_STABILITY_TEST)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered
Longterm stability DCS
(LONG_TERM_STABILITY_DCS)
No result N/A

Thermal Cycles (MODULE/THERMAL_CYCLES)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
Flatness
(FLATNESS)
No result N/A
IV measurement
(IV_MEASURE)
Registered Registered
Thermal Cycling
(THERMAL_CYCLING)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Post-Parylene Cold (MODULE/POST_PARYLENE_COLD)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Post-Parylene Warm (MODULE/POST_PARYLENE_WARM)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Wirebond Protection (alt) (MODULE/WIREBOND_PROTECTION)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Mass Measurement
(MASS_MEASUREMENT)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
No result N/A
Wire bonding protection roof envelope
(WP_ENVELOPE)
No result N/A

Parylene Unmasking (MODULE/PARYLENE_UNMASKING)

Test Local Result ProdDB Record
Parylene (de-)masking
(DE_MASKING)
No result N/A
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
Flatness
(FLATNESS)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Parylene Coating (MODULE/PARYLENE_COATING)

Test Local Result ProdDB Record
Parylene Properties
(PARYLENE)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Parylene Masking (MODULE/PARYLENE_MASKING)

Test Local Result ProdDB Record
Parylene (de-)masking
(DE_MASKING)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Initial Cold (MODULE/INITIAL_COLD)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
No result N/A

QC cross-check (module swapping) (MODULE/QC_CROSSCHECK)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A

Initial Warm (MODULE/INITIAL_WARM)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered

Wire Bonding (MODULE/WIREBONDING)

Test Local Result ProdDB Record
Visual Inspection
(VISUAL_INSPECTION)
No result N/A
Wirebond pull test
(WIREBOND_PULL_TEST)
No result N/A
Wirebonding Information
(WIREBONDING)
No result N/A

Bare module to module PCB assembly (MODULE/ASSEMBLY)

Test Local Result ProdDB Record
Flatness
(FLATNESS)
No result N/A
Glue Information Module+Flex Attach
(GLUE_MODULE_FLEX_ATTACH)
No result N/A
Mass Measurement
(MASS_MEASUREMENT)
No result N/A
Quad Module Metrology
(QUAD_MODULE_METROLOGY)
No result N/A
Triplet Module Metrology
(TRIPLET_METROLOGY)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Initial state to associate flex to bare module (MODULE/INIT)

LocalDB Test ID Stage Test Name Inspector Measurement Date Analysis Date Tags QC Registration
66a0f8…560907 MODULE/FINAL_COLD IV_MEASURE NirajKakoty a year ago a year ago No tags Selected
669fc4…55f7cb MODULE/FINAL_WARM IV_MEASURE NirajKakoty a year ago a year ago No tags Selected
669fbe…55f549 MODULE/LONG_TERM_STABILITY_TEST IV_MEASURE NirajKakoty a year ago a year ago No tags Selected
6697a2…e3698f MODULE/THERMAL_CYCLES IV_MEASURE NirajKakoty a year ago a year ago No tags Selected
6697a2…e36a81 MODULE/THERMAL_CYCLES THERMAL_CYCLING NirajKakoty N/A a year ago No tags Selected
668d09…41b116 MODULE/INITIAL_WARM IV_MEASURE JuanIgnacioCarlotto a year ago a year ago No tags Selected
66a0fd…560d01 MODULE/FINAL_COLD E_SUMMARY NirajKakoty N/A a year ago No tags Selected
669fc6…55fcc9 MODULE/FINAL_WARM E_SUMMARY NirajKakoty N/A a year ago No tags Selected
669fc0…55f6f7 MODULE/LONG_TERM_STABILITY_TEST E_SUMMARY NirajKakoty N/A a year ago No tags Selected
6697a2…e36a7e MODULE/THERMAL_CYCLES E_SUMMARY NirajKakoty N/A a year ago No tags Selected
669785…e367fb MODULE/INITIAL_COLD E_SUMMARY NirajKakoty N/A a year ago No tags Selected
668cee…2b9833 MODULE/INITIAL_WARM E_SUMMARY JuanIgnacioCarlotto N/A a year ago No tags Selected
667425…d7ef1d MODULE/ASSEMBLY TRIPLET_METROLOGY PabloFernández Martínez N/A a year ago No tags Selected
Stage Tests
MODULE/INIT
MODULE/ASSEMBLY
  • Mass Measurement  (MASS_MEASUREMENT)
  • Glue Information Module+Flex Attach  (GLUE_MODULE_FLEX_ATTACH)
  • Triplet Module Metrology  (TRIPLET_METROLOGY)
  • Visual Inspection  (VISUAL_INSPECTION)
  • Flatness  (FLATNESS)
  • Quad Module Metrology  (QUAD_MODULE_METROLOGY)
MODULE/WIREBONDING
  • Wirebonding Information  (WIREBONDING)
  • Wirebond pull test  (WIREBOND_PULL_TEST)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/INITIAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/QC_CROSSCHECK
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/INITIAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/PARYLENE_MASKING
  • Visual Inspection  (VISUAL_INSPECTION)
  • Parylene (de-)masking  (DE_MASKING)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/PARYLENE_COATING
  • Parylene Properties  (PARYLENE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/PARYLENE_UNMASKING
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Parylene (de-)masking  (DE_MASKING)
MODULE/WIREBOND_PROTECTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Wire bonding protection roof envelope  (WP_ENVELOPE)
  • Mass Measurement  (MASS_MEASUREMENT)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
MODULE/POST_PARYLENE_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/POST_PARYLENE_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/THERMAL_CYCLES
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Thermal Cycling  (THERMAL_CYCLING)
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
MODULE/LONG_TERM_STABILITY_TEST
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Longterm stability DCS  (LONG_TERM_STABILITY_DCS)
MODULE/FINAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/FINAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/FINAL_METROLOGY
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/QC_STATUS
  • Module ranking  (RANKING)
MODULE/UNHAPPY
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/NOTCONSIDEREDINYIELDS
MODULE/GRAVEYARD
MODULE/COMPLETE
MODULE/RECEPTION
  • Visual Inspection  (VISUAL_INSPECTION)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/TAB_CUTTING
  • Mass Measurement  (MASS_MEASUREMENT)
  • Module PCB Tab Cutting Information  (CUTTER_PCB_TAB)
  • Visual Inspection  (VISUAL_INSPECTION)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
LLS/PRE_TC_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/PRE_TC_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/POST_TC_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/POST_TC_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/RECEPTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
OB_LOADED_MODULE_CELL/INIT
OB_LOADED_MODULE_CELL/ASSEMBLY
OB_LOADED_MODULE_CELL/THERMAL_CYCLES
OB_LOADED_MODULE_CELL/FINAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/FINAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/THERMAL_COLD
  • Thermal Measure  (THERMAL_PERFORMANCE)
OB_LOADED_MODULE_CELL/THERMAL_WARM
  • Thermal Measure  (THERMAL_PERFORMANCE)
OB_LOADED_MODULE_CELL/ENVELOPE_CHECK
OB_LOADED_MODULE_CELL/QC_STATUS
OB_LOADED_MODULE_CELL/UNHAPPY
OB_LOADED_MODULE_CELL/COMPLETE
OB_LOADED_MODULE_CELL/RECEPTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/TAB_CUTTING
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Module PCB Tab Cutting Information  (CUTTER_PCB_TAB)
OB_LOADED_MODULE_CELL/PIGTAIL_INSERTION
Back to top page of this component