20UPGM24220303 (ANL_ITkPix_246)

MODULE/POST_PARYLENE_WARM

Component Information

Serial Number 20UPGM24220303
ProdDB ID  0e22d6…3f5e50
LocalDB ID 69c57a7b94cbc6ecfb52afd3
Component Type MODULE
Parents No match.
Children 20UPGB43000389 Bare Module 20UPGFC0223314 FE Chip 20UPGFC0223315 FE Chip 20UPGFC0223324 FE Chip 20UPGFC0223316 FE Chip 20UPGPQ4220303 PCB
Flags
Distribution of chips on wafer

 Properties

Item Value
FE chip version 3
PCB-Bare Orientation isNormal True
Alternative ID ANL_ITkPix_246
Wirebond protection roof presence None
Rank None
Is preproduction module None

 Comments

 Current Stage: Post-Parylene Warm

Test Type Local Result
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No TestRun!
IV measurement
(IV_MEASURE)
No TestRun!
Visual Inspection
(VISUAL_INSPECTION)
No TestRun!

 Candidate TestRuns of this Stage

LDB ID TestRun Code QC Passed Inspector Measurement Date Analysis Date Analysis Version Tags QC Registration

Past QC Stages and Results

Wirebond Protection (alt) (MODULE/WIREBOND_PROTECTION)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Mass Measurement
(MASS_MEASUREMENT)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
No result N/A
Wire bonding protection roof envelope
(WP_ENVELOPE)
No result N/A

Parylene Unmasking (MODULE/PARYLENE_UNMASKING)

Test Local Result ProdDB Record
Parylene (de-)masking
(DE_MASKING)
No result N/A
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
Flatness
(FLATNESS)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered

Parylene Coating (MODULE/PARYLENE_COATING)

Test Local Result ProdDB Record
Parylene Properties
(PARYLENE)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered

Parylene Masking (MODULE/PARYLENE_MASKING)

Test Local Result ProdDB Record
Parylene (de-)masking
(DE_MASKING)
Registered Registered
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered

Initial Cold (MODULE/INITIAL_COLD)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A

QC cross-check (module swapping) (MODULE/QC_CROSSCHECK)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Initial Warm (MODULE/INITIAL_WARM)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered

Wire Bonding (MODULE/WIREBONDING)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered
Wirebond pull test
(WIREBOND_PULL_TEST)
No result N/A
Wirebonding Information
(WIREBONDING)
Registered Registered

Bare module to module PCB assembly (MODULE/ASSEMBLY)

Test Local Result ProdDB Record
Flatness
(FLATNESS)
No result N/A
Glue Information Module+Flex Attach
(GLUE_MODULE_FLEX_ATTACH)
Registered Registered
Mass Measurement
(MASS_MEASUREMENT)
Registered Registered
Quad Module Metrology
(QUAD_MODULE_METROLOGY)
Registered Registered
Triplet Module Metrology
(TRIPLET_METROLOGY)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Initial state to associate flex to bare module (MODULE/INIT)

LocalDB Test ID Stage Test Name Inspector Measurement Date Analysis Date Tags QC Registration
69f50a…ef07bc MODULE/PARYLENE_UNMASKING VISUAL_INSPECTION Simpson,Liana Rae a month ago a month ago No tags Selected
69f26a…ea62fd MODULE/PARYLENE_COATING VISUAL_INSPECTION Simpson,Liana Rae a month ago a month ago No tags Selected
69f4dd…95612e MODULE/PARYLENE_COATING PARYLENE Simpson,Liana Rae N/A a month ago No tags Selected
69f4dc…42d7c9 MODULE/PARYLENE_MASKING DE_MASKING Simpson,Liana Rae N/A a month ago No tags Selected
69f25b…ea5f81 MODULE/PARYLENE_MASKING VISUAL_INSPECTION Simpson,Liana Rae a month ago a month ago No tags Selected
69dfd1…e8e1d7 MODULE/INITIAL_WARM IV_MEASURE Simpson,Liana Rae a month ago a month ago No tags Selected
69dff8…e8f55d MODULE/INITIAL_WARM E_SUMMARY Simpson,Liana Rae N/A a month ago No tags Selected
69d6e3…e88d41 MODULE/WIREBONDING VISUAL_INSPECTION DanielAceves 2 months ago 2 months ago No tags Selected
69ce99…b75831 MODULE/WIREBONDING WIREBONDING DanielAceves N/A 2 months ago No tags Selected
69ce9c…b7c11e MODULE/ASSEMBLY QUAD_MODULE_METROLOGY DanielAceves N/A 2 months ago No tags Selected
69ce95…b70a74 MODULE/ASSEMBLY GLUE_MODULE_FLEX_ATTACH DanielAceves N/A 2 months ago No tags Selected
69ce96…a3f0bf MODULE/ASSEMBLY MASS_MEASUREMENT DanielAceves N/A 2 months ago No tags Selected
Stage Tests
MODULE/INIT
MODULE/ASSEMBLY
  • Mass Measurement  (MASS_MEASUREMENT)
  • Glue Information Module+Flex Attach  (GLUE_MODULE_FLEX_ATTACH)
  • Triplet Module Metrology  (TRIPLET_METROLOGY)
  • Visual Inspection  (VISUAL_INSPECTION)
  • Flatness  (FLATNESS)
  • Quad Module Metrology  (QUAD_MODULE_METROLOGY)
MODULE/WIREBONDING
  • Wirebonding Information  (WIREBONDING)
  • Wirebond pull test  (WIREBOND_PULL_TEST)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/INITIAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/QC_CROSSCHECK
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/INITIAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/PARYLENE_MASKING
  • Visual Inspection  (VISUAL_INSPECTION)
  • Parylene (de-)masking  (DE_MASKING)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/PARYLENE_COATING
  • Parylene Properties  (PARYLENE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/PARYLENE_UNMASKING
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Parylene (de-)masking  (DE_MASKING)
MODULE/WIREBOND_PROTECTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Wire bonding protection roof envelope  (WP_ENVELOPE)
  • Mass Measurement  (MASS_MEASUREMENT)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
MODULE/POST_PARYLENE_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/POST_PARYLENE_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/THERMAL_CYCLES
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Thermal Cycling  (THERMAL_CYCLING)
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
MODULE/LONG_TERM_STABILITY_TEST
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Longterm stability DCS  (LONG_TERM_STABILITY_DCS)
MODULE/FINAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/FINAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/FINAL_METROLOGY
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/QC_STATUS
  • Module ranking  (RANKING)
MODULE/UNHAPPY
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/NOTCONSIDEREDINYIELDS
MODULE/GRAVEYARD
MODULE/COMPLETE
MODULE/RECEPTION
  • Visual Inspection  (VISUAL_INSPECTION)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/TAB_CUTTING
  • Mass Measurement  (MASS_MEASUREMENT)
  • Module PCB Tab Cutting Information  (CUTTER_PCB_TAB)
  • Visual Inspection  (VISUAL_INSPECTION)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
LLS/PRE_TC_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/PRE_TC_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/POST_TC_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/POST_TC_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/RECEPTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
OB_LOADED_MODULE_CELL/INIT
OB_LOADED_MODULE_CELL/ASSEMBLY
OB_LOADED_MODULE_CELL/WIREBOND_PROTECTION
OB_LOADED_MODULE_CELL/THERMAL_CYCLES
OB_LOADED_MODULE_CELL/FINAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/FINAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/THERMAL_COLD
  • Thermal Measure  (THERMAL_PERFORMANCE)
OB_LOADED_MODULE_CELL/THERMAL_WARM
  • Thermal Measure  (THERMAL_PERFORMANCE)
OB_LOADED_MODULE_CELL/ENVELOPE_CHECK
OB_LOADED_MODULE_CELL/QC_STATUS
OB_LOADED_MODULE_CELL/UNHAPPY
OB_LOADED_MODULE_CELL/GRAVEYARD
OB_LOADED_MODULE_CELL/COMPLETE
OB_LOADED_MODULE_CELL/RECEPTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/TAB_CUTTING
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Module PCB Tab Cutting Information  (CUTTER_PCB_TAB)
OB_LOADED_MODULE_CELL/PIGTAIL_INSERTION
Back to top page of this component