20UPIM04202229

MODULE/INITIAL_COLD

Component Information

Serial Number 20UPIM04202229
ProdDB ID  07b4d9…f3a08c
LocalDB ID 6925727915280561fda3fdd6
Component Type MODULE
Parents No match.
Children 20UPGB13200124 Bare Module 20UPGFC0220551 FE Chip 20UPGB13200125 Bare Module 20UPGFC0220567 FE Chip 20UPGB13200126 Bare Module 20UPGFC0220583 FE Chip 20UPIP05252229 PCB
Flags
Distribution of chips on wafer

 Properties

Item Value
FE chip version 3
PCB-Bare Orientation isNormal True
Wirebond protection roof presence None
Alternative ID None
Rank None
Is preproduction module None

 Comments


Test: WIREBOND_PULL_TEST QC Passed

(Stage: MODULE/WIREBONDING)


Result of Wirebond Pull Test

Scan

Key Data
component id 6925727915280561fda3fdd6
Stage MODULE/WIREBONDING
test Type WIREBOND_PULL_TEST
institute 64657cef8d79bac1f3f0055a
user RagnhildHallaraker

Result

Key Data
properties {'ANALYSIS_VERSION': '1', 'INSTRUMENT': 'FK Delvotec 5600-C', 'MEASUREMENT_DATE': '2025-11-26T16:13:21.626Z', 'MEASUREMENT_DURATION': None, 'OPERATOR_IDENTITY': 'RSH'} g
BOND_PEEL 0 g
DATA_UNAVAILABLE False g
HEEL_BREAKS_ON_FE_CHIP 100 g
HEEL_BREAKS_ON_PCB 0 g
LIFT_OFFS_LESS_THAN_7G 0 g
PULL_STRENGTH 11.53 g
PULL_STRENGTH_DATA [[[11.51, 2, 3]], [[11.58, 2, 3]], [[12.35, 2, 3]], [[12.19, 2, 3]], [[10.99, 2, 3]], [[10.69, 2, 2]], [[11.3, 2, 2]], [[11.32, 2, 2]], [[11.58, 2, 2]], [[11.64, 2, 2]], [[11.07, 2, 1]], [[11.68, 2, 1]], [[11.42, 2, 1]], [[11.44, 2, 1]], [[12.16, 2, 1]]] g
PULL_STRENGTH_ERROR 0.45 g
PULL_STRENGTH_MAX 12.35 g
PULL_STRENGTH_MIN 10.69 g
WIRE_BREAKS_5G 0 g
WIRE_PULLS 15 g

ProductionDB Record

id694575b0443fc79a1e303eee
stateready
stateTs2025-12-19T15:56:32.392Z
stateUserIdentity4287-3818-1
date2025-12-19T16:56:18.000Z
testType
id63fb635d4069b50036d3faac
codeWIREBOND_PULL_TEST
nameWirebond pull test
stateactive
institution
id5a832050daf1a000052e3e98
codeUIO
nameUniversity of Oslo, Department of Physics
user
id61375da68fc62a000ab9a162
userIdentity4287-3818-1
firstNameRagnhild
middleName
lastNameHallaraker
runNumber1
passedTrue
problemsFalse
properties
codenamedataTypevalueTyperequiredvaluerangeMinrangeMax
ANALYSIS_VERSIONAnalysis VersionstringsingleFalse1NoneNone
INSTRUMENTInstrumentstringsingleFalseFK Delvotec 5600-CNoneNone
MEASUREMENT_DATEDate measurement performeddatetimeNoneFalse2025-11-26T16:13:21.626ZNoneNone
MEASUREMENT_DURATIONMeasurement durationintegerNoneFalseNoneNoneNone
OPERATOR_IDENTITYOperator NamestringsingleFalseRSHNoneNone
results
  • codeBOND_PEEL
    namePercentage of Lift Offs (i.e. bond peel) on FE chip or PCB [%]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value0
    associateChildNone
  • codeDATA_UNAVAILABLE
    nameData unavailable
    dataTypeboolean
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    valueFalse
    associateChildNone
  • codeHEEL_BREAKS_ON_FE_CHIP
    namePercentage of heel breaks on FE chips [%]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value100
    associateChildNone
  • codeHEEL_BREAKS_ON_PCB
    namePercentage of heel breaks on PCB [%]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value0
    associateChildNone
  • codeLIFT_OFFS_LESS_THAN_7G
    namePercentage of liftoffs < 7g [%]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value0
    associateChildNone
  • codePULL_STRENGTH
    nameMean pull strength [g]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value11.53
    associateChildNone
  • codePULL_STRENGTH_DATA
    namePull strength data
    order1
    dataTypefloat
    valueTypearray
    arrayDimensions3
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value
        • 11.51
        • 2
        • 3
        • 11.58
        • 2
        • 3
        • 12.35
        • 2
        • 3
        • 12.19
        • 2
        • 3
        • 10.99
        • 2
        • 3
        • 10.69
        • 2
        • 2
        • 11.3
        • 2
        • 2
        • 11.32
        • 2
        • 2
        • 11.58
        • 2
        • 2
        • 11.64
        • 2
        • 2
        • 11.07
        • 2
        • 1
        • 11.68
        • 2
        • 1
        • 11.42
        • 2
        • 1
        • 11.44
        • 2
        • 1
        • 12.16
        • 2
        • 1
    associateChildNone
  • codePULL_STRENGTH_ERROR
    nameStd deviation of pull strength [g]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value0.45
    associateChildNone
  • codePULL_STRENGTH_MAX
    nameMaximum pull strength [g]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value12.35
    associateChildNone
  • codePULL_STRENGTH_MIN
    nameMinimum pull strength [g]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value10.69
    associateChildNone
  • codeWIRE_BREAKS_5G
    nameNumber of wires breaking before 5g
    dataTypeinteger
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value0
    associateChildNone
  • codeWIRE_PULLS
    nameNumber of wires pulled
    dataTypeinteger
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value15
    associateChildNone
cts2025-12-19T15:56:32.392Z
sys
cts2025-12-19T15:56:32.392Z
mts2025-12-19T15:56:32.392Z
rev0
defects
commentsNone
attachments
components
idcodestatestateTsstateUserIdentitydummycompletedcompletedTscompletedUserIdentitytrashedtrashedTstrashedUserIdentityserialNumberalternativeIdentifierprojectsubprojectcomponentTypetypepropertiestestedAtStageinstitution
6925727915280561fda3fdd607b4d9f556db8db7559ebe0b2af3a08cready2025-11-25T09:10:17.219Z5307-101-1FalseFalseNoneNoneFalseNoneNone20UPIM04202229None
codeP
namePixels
codePI
nameInner pixels
codeMODULE
nameModule
codeTRIPLET_L0_RING0_MODULE
nameTriplet L0 Ring0 module
  • codeFECHIP_VERSION
    nameFE chip version
    dataTypecodeTable
    requiredTrue
    defaultFalse
    valueITkpix_v2
    codeTable
    codevalue
    0RD53A
    1ITkpix_v1
    2ITkpix_v1.1
    3ITkpix_v2
    9No FE chip
  • codeORIENTATION
    namePCB-Bare Orientation isNormal
    dataTypeboolean
    requiredTrue
    defaultFalse
    valueTrue
codeMODULE/WIREBONDING
nameWire Bonding
order2
initialFalse
finalFalse
codeUIO
nameUniversity of Oslo, Department of Physics

 Current Stage: Initial Cold

Test Type Local Result
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No TestRun!
IV measurement
(IV_MEASURE)
No TestRun!

 Candidate TestRuns of this Stage

LDB ID TestRun Code QC Passed Inspector Measurement Date Analysis Date Analysis Version Tags QC Registration
694575…303eee WIREBOND_PULL_TEST Pass RagnhildHallaraker N/A 6 months ago 1 No tags Selected
694575…dc8547 WIREBONDING Pass RagnhildHallaraker N/A 6 months ago No tags Selected

Past QC Stages and Results

QC cross-check (module swapping) (MODULE/QC_CROSSCHECK)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Initial Warm (MODULE/INITIAL_WARM)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered

Wire Bonding (MODULE/WIREBONDING)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
No result N/A
Wirebond pull test
(WIREBOND_PULL_TEST)
Registered Registered
Wirebonding Information
(WIREBONDING)
Registered Registered

Bare module to module PCB assembly (MODULE/ASSEMBLY)

Test Local Result ProdDB Record
Flatness
(FLATNESS)
No result N/A
Glue Information Module+Flex Attach
(GLUE_MODULE_FLEX_ATTACH)
No result N/A
Mass Measurement
(MASS_MEASUREMENT)
No result N/A
Quad Module Metrology
(QUAD_MODULE_METROLOGY)
No result N/A
Triplet Module Metrology
(TRIPLET_METROLOGY)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Initial state to associate flex to bare module (MODULE/INIT)

LocalDB Test ID Stage Test Name Inspector Measurement Date Analysis Date Tags QC Registration
6932d3…45d42b MODULE/INITIAL_WARM IV_MEASURE OleRohne 6 months ago 4 months ago No tags Selected
6992e4…da7e84 MODULE/INITIAL_WARM E_SUMMARY OleRohne N/A 4 months ago No tags Selected
698c8f…d0a422 MODULE/FINAL_COLD IV_MEASURE SimenHellesund 4 months ago 4 months ago No tags Selected
698ca4…d0a798 MODULE/FINAL_COLD E_SUMMARY SimenHellesund N/A 4 months ago No tags Selected
698c8d…760b6d MODULE/THERMAL_CYCLES THERMAL_CYCLING SimenHellesund N/A 4 months ago No tags Selected
698c84…d0a330 MODULE/FINAL_WARM IV_MEASURE SimenHellesund 4 months ago 4 months ago No tags Selected
698c8c…d0a3e8 MODULE/FINAL_WARM E_SUMMARY SimenHellesund N/A 4 months ago No tags Selected
698b05…d09e89 MODULE/POST_PARYLENE_WARM E_SUMMARY SimenHellesund N/A 4 months ago No tags Selected
694575…303eee MODULE/WIREBONDING WIREBOND_PULL_TEST RagnhildHallaraker N/A 6 months ago No tags Selected
694575…dc8547 MODULE/WIREBONDING WIREBONDING RagnhildHallaraker N/A 6 months ago No tags Selected
Stage Tests
MODULE/INIT
MODULE/ASSEMBLY
  • Mass Measurement  (MASS_MEASUREMENT)
  • Glue Information Module+Flex Attach  (GLUE_MODULE_FLEX_ATTACH)
  • Triplet Module Metrology  (TRIPLET_METROLOGY)
  • Visual Inspection  (VISUAL_INSPECTION)
  • Flatness  (FLATNESS)
  • Quad Module Metrology  (QUAD_MODULE_METROLOGY)
MODULE/WIREBONDING
  • Wirebonding Information  (WIREBONDING)
  • Wirebond pull test  (WIREBOND_PULL_TEST)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/INITIAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/QC_CROSSCHECK
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/INITIAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/PARYLENE_MASKING
  • Visual Inspection  (VISUAL_INSPECTION)
  • Parylene (de-)masking  (DE_MASKING)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/PARYLENE_COATING
  • Parylene Properties  (PARYLENE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/PARYLENE_UNMASKING
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Parylene (de-)masking  (DE_MASKING)
MODULE/WIREBOND_PROTECTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Wire bonding protection roof envelope  (WP_ENVELOPE)
  • Mass Measurement  (MASS_MEASUREMENT)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
MODULE/POST_PARYLENE_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/POST_PARYLENE_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/THERMAL_CYCLES
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Thermal Cycling  (THERMAL_CYCLING)
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
MODULE/LONG_TERM_STABILITY_TEST
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Longterm stability DCS  (LONG_TERM_STABILITY_DCS)
MODULE/FINAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/FINAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/FINAL_METROLOGY
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/QC_STATUS
  • Module ranking  (RANKING)
MODULE/UNHAPPY
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/NOTCONSIDEREDINYIELDS
MODULE/GRAVEYARD
MODULE/COMPLETE
MODULE/RECEPTION
  • Visual Inspection  (VISUAL_INSPECTION)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/TAB_CUTTING
  • Mass Measurement  (MASS_MEASUREMENT)
  • Module PCB Tab Cutting Information  (CUTTER_PCB_TAB)
  • Visual Inspection  (VISUAL_INSPECTION)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
LLS/PRE_TC_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/PRE_TC_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/POST_TC_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/POST_TC_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/RECEPTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
OB_LOADED_MODULE_CELL/INIT
OB_LOADED_MODULE_CELL/ASSEMBLY
OB_LOADED_MODULE_CELL/WIREBOND_PROTECTION
OB_LOADED_MODULE_CELL/THERMAL_CYCLES
OB_LOADED_MODULE_CELL/FINAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/FINAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/THERMAL_COLD
  • Thermal Measure  (THERMAL_PERFORMANCE)
OB_LOADED_MODULE_CELL/THERMAL_WARM
  • Thermal Measure  (THERMAL_PERFORMANCE)
OB_LOADED_MODULE_CELL/ENVELOPE_CHECK
OB_LOADED_MODULE_CELL/QC_STATUS
OB_LOADED_MODULE_CELL/UNHAPPY
OB_LOADED_MODULE_CELL/GRAVEYARD
OB_LOADED_MODULE_CELL/COMPLETE
OB_LOADED_MODULE_CELL/RECEPTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/TAB_CUTTING
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Module PCB Tab Cutting Information  (CUTTER_PCB_TAB)
OB_LOADED_MODULE_CELL/PIGTAIL_INSERTION
Back to top page of this component