20UPGB43000504

MODULE/GRAVEYARD

Component Information

Serial Number 20UPGB43000504
ProdDB ID  057892…ae74ef
LocalDB ID 69146ebf44c06a976380d67b
Component Type BARE_MODULE
Parents 20UPGM24810360
Children 20UPGFC0224845 FE Chip 20UPGFC0224819 FE Chip 20UPGFC0224821 FE Chip 20UPGFC0224820 FE Chip 20UPGS33303027 Sensor Tile
Flags
Distribution of chips on wafer

 Properties

Item Value
FE chip version readonly 3
Sensor Type 5
Vendor code readonly 0
Thickness of FE chips (RD53A) None

 Comments


Test: VISUAL_INSPECTION QC Passed

(Stage: BAREMODULERECEPTION)


Basic View Only: custom view for this TestRun is not prepared.

Metadata

Key Data
QC Passed True
Date 5 months ago
component ObjectId 69146ebf44c06a976380d67b
Stage BAREMODULERECEPTION
Test Type VISUAL_INSPECTION
Institute ObjectId
User Name ThomasNaquin
ObjectId of this record 6924684907e8852b92752e50
ObjectId of RAW record None
Tags No tags

Results

Key Data
ANALYSIS_VERSION mqat v1
MEASUREMENT_DATE 2025-11-23T23:00:00.000Z
DEFECTS ['4']
FE_CHIP_CONDITION_PASSED_QC 1
GLUE_DISTRIBUTION_PASSED_QC N/A
OBWBP_ASSEMBLY_PASSED_QC N/A
PARYLENE_COATING_PASSED_QC N/A
SENSOR_CONDITION_PASSED_QC 1
SMD_COMPONENTS_PASSED_QC N/A
STRAIN_RELIEF_PASSED_QC N/A
WIREBONDING_PASSED_QC N/A

ProductionDB Record

id6924684907e8852b92752e50
stateready
stateTs2025-11-24T14:14:33.943Z
stateUserIdentity8769-4020-1
date2025-11-24T14:13:00.000Z
testType
id5f869f6646cd14000b5108c6
codeVISUAL_INSPECTION
nameVisual Inspection
stateactive
institution
id5d372a3becb4750009835557
codeIJCLAB
nameLaboratoire de Physique des 2 Infinis Irène Joliot-Curie (IJCLab)
user
id66e9329c0fc5b30042e7f088
userIdentity8769-4020-1
firstNameThomas
middleName
lastNameNaquin
runNumber1
passedTrue
problemsFalse
properties
codenamedataTypevalueTyperequiredvaluerangeMinrangeMax
ANALYSIS_VERSIONAnalysis VersionstringsingleFalse1NoneNone
MEASUREMENT_DATEDate measurement performeddatetimeNoneFalse2025-11-23T23:00:00.000ZNoneNone
results
  • codeDEFECTS
    nameDefect source
    dataTypecodeTable
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    value
    • 4
    associateChildNone
    codeTable
    codevalue
    0no defect
    1Sensor systematic rough edge or dicing defect
    2Sensor tooling marks
    3Sensor scratch (random)
    4Sensor dot-like contamination
    5Sensor chipped corner
    6FE chip chipped outer corner
    7FE chip bond pad contamination
    8FE chip irregular dicing
    9FE chip scratch on back side
    10FE chip scratch on top side (pad side)
    11FE chip chipped inner corner
    12FE chip excess material (not diced near FE border)
    13Other defect
  • codeFE_CHIP_CONDITION_PASSED_QC
    nameFE chip condition passed QC (1: good, 2: issues, 3: bad)
    dataTypeinteger
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    value1
    associateChildNone
  • codeGLUE_DISTRIBUTION_PASSED_QC
    nameGlue distribution passed QC (not applicable for bare module reception, 1: good, 2: issues, 3: bad)
    dataTypeinteger
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    valueNone
    associateChildNone
  • codeOBWBP_ASSEMBLY_PASSED_QC
    nameOBWP assembly passed QC (not applicable for bare module reception, 1: good, 2: issues, 3: bad)
    dataTypeinteger
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    valueNone
    associateChildNone
  • codePARYLENE_COATING_PASSED_QC
    nameParylene coating passed QC (not applicable for bare module reception, 1: good, 2: issues, 3: bad)
    dataTypeinteger
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    valueNone
    associateChildNone
  • codeSENSOR_CONDITION_PASSED_QC
    nameSensor condition passed QC (1: good, 2: issues, 3: bad)
    dataTypeinteger
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    value1
    associateChildNone
  • codeSMD_COMPONENTS_PASSED_QC
    nameSMD components passed QC (not required for bare modules) (1: good, 2: issues, 3: bad)
    dataTypeinteger
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    valueNone
    associateChildNone
  • codeSTRAIN_RELIEF_PASSED_QC
    nameStrain relief passed QC (not applicable for bare module reception, 1: good, 2: issues, 3: bad)
    dataTypeinteger
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    valueNone
    associateChildNone
  • codeWIREBONDING_PASSED_QC
    nameWirebonding passed QC (not applicable for bare module reception, 1: good, 2: issues, 3: bad)
    dataTypeinteger
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    valueNone
    associateChildNone
cts2025-11-24T14:14:33.943Z
sys
cts2025-11-24T14:14:33.943Z
mts2025-11-24T14:14:33.943Z
rev0
defects
commentsNone
attachments
components
idcodestatestateTsstateUserIdentitydummycompletedcompletedTscompletedUserIdentitytrashedtrashedTstrashedUserIdentityserialNumberalternativeIdentifierprojectsubprojectcomponentTypetypepropertiestestedAtStageinstitution
69146ebf44c06a976380d67b057892aa3908508c1068a4fbdfae74efready2025-11-12T11:25:51.374Z23-6780-1FalseFalseNoneNoneFalseNoneNone20UPGB43000504None
codeP
namePixels
codePG
namePixel general
codeBARE_MODULE
nameBare Module
codeQUAD_BARE_MODULE
nameQuad bare module
codenamedataTyperequireddefaultvaluecodeTable
FECHIP_VERSIONFE chip versioncodeTableTrueFalseITkpix_v2
codevalue
0RD53A
1ITkpix_v1
2ITkpix_v1.1
3ITkpix_v2
9No FE chip
SENSOR_TYPESensor TypecodeTableTrueFalseOuter pixel quad sensor tile
codevalue
0No sensor
1Market survey sensor tile
2L0 inner pixel 3D sensor tile
3L0 inner pixel planar sensor tile
4L1 inner pixel quad sensor tile
5Outer pixel quad sensor tile
9Dummy sensor tile
VENDORVendor codecodeTableTrueFalseAdvacam
codevalue
0Advacam
1Leonardo
2IZM
3HPK (in-kind)
4HPK (CERN order)
5RAL (in-house)
6Glasgow (in-house)
9ITk institute
codeBAREMODULERECEPTION
nameReception at ITk institute
order3
initialFalse
finalFalse
codeADVACAM
nameAdvacam Oy

 Current Stage: Modules damaged, impossible to recover

Past QC Stages and Results

Stage for QA modules and others not to be considered in yield calculation (MODULE/NOTCONSIDEREDINYIELDS)

Modules failed test, needs investigation (MODULE/UNHAPPY)

Ranking of the module (MODULE/QC_STATUS)

Final flatness measurement (MODULE/FINAL_METROLOGY)

Final Cold (MODULE/FINAL_COLD)

Final Warm (MODULE/FINAL_WARM)

Long Term Stability Test (MODULE/LONG_TERM_STABILITY_TEST)

Thermal Cycles (MODULE/THERMAL_CYCLES)

Post-Parylene Cold (MODULE/POST_PARYLENE_COLD)

Post-Parylene Warm (MODULE/POST_PARYLENE_WARM)

Wirebond Protection (alt) (MODULE/WIREBOND_PROTECTION)

Parylene Unmasking (MODULE/PARYLENE_UNMASKING)

Parylene Coating (MODULE/PARYLENE_COATING)

Parylene Masking (MODULE/PARYLENE_MASKING)

Initial Cold (MODULE/INITIAL_COLD)

QC cross-check (module swapping) (MODULE/QC_CROSSCHECK)

Initial Warm (MODULE/INITIAL_WARM)

Wire Bonding (MODULE/WIREBONDING)

Bare module to module PCB assembly (MODULE/ASSEMBLY)

Initial state to associate flex to bare module (MODULE/INIT)

Reception at ITk institute (BAREMODULERECEPTION)

Test Local Result ProdDB Record
Sensor IV on bare module
(BARE_MODULE_SENSOR_IV)
Registered Registered
Flatness
(FLATNESS)
Registered Registered
Mass Measurement
(MASS_MEASUREMENT)
Registered Registered
Quad Bare Module Metrology
(QUAD_BARE_MODULE_METROLOGY)
Registered Registered
Single Bare Module Metrology
(SINGLE_BARE_MODULE_METROLOGY)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered

Not to be used for the detector (NOT_USED)

Bare module failed test, needs investigation (UNHAPPY)

Bare module assembly (BAREMODULEASSEMBLY)

LocalDB Test ID Stage Test Name Inspector Measurement Date Analysis Date Tags QC Registration
6932e6…c7d3c8 BAREMODULERECEPTION FLATNESS AbdoulayeNDIAYE N/A 4 months ago No tags Selected
6932e5…9042f9 BAREMODULERECEPTION MASS_MEASUREMENT AbdoulayeNDIAYE N/A 4 months ago No tags Selected
6932e2…9034d4 BAREMODULERECEPTION BARE_MODULE_SENSOR_IV AbdoulayeNDIAYE N/A 4 months ago No tags Selected
692468…752e50 BAREMODULERECEPTION VISUAL_INSPECTION ThomasNaquin N/A 5 months ago No tags Selected
Stage Tests
BAREMODULEASSEMBLY
UNHAPPY
NOT_USED
BAREMODULERECEPTION
  • Visual Inspection  (VISUAL_INSPECTION)
  • Mass Measurement  (MASS_MEASUREMENT)
  • Quad Bare Module Metrology  (QUAD_BARE_MODULE_METROLOGY)
  • Flatness  (FLATNESS)
  • Sensor IV on bare module  (BARE_MODULE_SENSOR_IV)
  • Single Bare Module Metrology  (SINGLE_BARE_MODULE_METROLOGY)
MODULE/INIT
MODULE/ASSEMBLY
MODULE/WIREBONDING
MODULE/INITIAL_WARM
MODULE/QC_CROSSCHECK
MODULE/INITIAL_COLD
MODULE/PARYLENE_MASKING
MODULE/PARYLENE_COATING
MODULE/PARYLENE_UNMASKING
MODULE/WIREBOND_PROTECTION
MODULE/POST_PARYLENE_WARM
MODULE/POST_PARYLENE_COLD
MODULE/THERMAL_CYCLES
MODULE/LONG_TERM_STABILITY_TEST
MODULE/FINAL_WARM
MODULE/FINAL_COLD
MODULE/FINAL_METROLOGY
MODULE/QC_STATUS
MODULE/UNHAPPY
MODULE/NOTCONSIDEREDINYIELDS
MODULE/GRAVEYARD
MODULE/COMPLETE
MODULE/RECEPTION
MODULE/TAB_CUTTING
LLS/PRE_TC_WARM
LLS/PRE_TC_COLD
LLS/POST_TC_WARM
LLS/POST_TC_COLD
LLS/RECEPTION
OB_LOADED_MODULE_CELL/INIT
OB_LOADED_MODULE_CELL/ASSEMBLY
OB_LOADED_MODULE_CELL/WIREBOND_PROTECTION
OB_LOADED_MODULE_CELL/THERMAL_CYCLES
OB_LOADED_MODULE_CELL/FINAL_WARM
OB_LOADED_MODULE_CELL/FINAL_COLD
OB_LOADED_MODULE_CELL/THERMAL_COLD
OB_LOADED_MODULE_CELL/THERMAL_WARM
OB_LOADED_MODULE_CELL/ENVELOPE_CHECK
OB_LOADED_MODULE_CELL/QC_STATUS
OB_LOADED_MODULE_CELL/UNHAPPY
OB_LOADED_MODULE_CELL/COMPLETE
OB_LOADED_MODULE_CELL/RECEPTION
OB_LOADED_MODULE_CELL/TAB_CUTTING
OB_LOADED_MODULE_CELL/PIGTAIL_INSERTION
Back to top page of this component