20UPGB43000296

MODULE/POST_PARYLENE_COLD

Component Information

Serial Number 20UPGB43000296
ProdDB ID  6754a4…9570fc
LocalDB ID 68d2c40ab5f1d1f55a7bf864
Component Type BARE_MODULE
Parents 20UPGM24830264
Children 20UPGFC0223158 FE Chip 20UPGFC0223160 FE Chip 20UPGFC0223164 FE Chip 20UPGFC0223162 FE Chip 20UPGS33304331 Sensor Tile
Flags
Distribution of chips on wafer

 Properties

Item Value
FE chip version readonly 3
Sensor Type 5
Vendor code readonly 0
Thickness of FE chips (RD53A) None

 Comments


Test: QUAD_BARE_MODULE_METROLOGY QC Passed

(Stage: BAREMODULERECEPTION)


Basic View Only: custom view for this TestRun is not prepared.

Metadata

Key Data
QC Passed True
Date 7 months ago
component ObjectId 68d2c40ab5f1d1f55a7bf864
Stage BAREMODULERECEPTION
Test Type QUAD_BARE_MODULE_METROLOGY
Institute ObjectId
User Name ElizaHoward
ObjectId of this record 69092ac246c81c946fe5f8bb
ObjectId of RAW record None
Tags No tags

Results

Key Data
ANALYSIS_VERSION mqat vNone
MEASUREMENT_DATE None
MEASUREMENT_DURATION None
OPERATOR_IDENTITY None
BARE_MODULE_THICKNESS 333.3
BARE_MODULE_THICKNESS_STD_DEVIATION 4.4
FECHIPS_X 42.22069
FECHIPS_Y 40.29603
FECHIP_THICKNESS 163
FECHIP_THICKNESS_STD_DEVIATION 3
SENSOR_X 39.54577
SENSOR_Y 41.13523

ProductionDB Record

id690e4cca20ebd175bf44c1ed
stateready
stateTs2025-11-07T19:47:22.634Z
stateUserIdentity4561-2270-1
date2025-11-03T22:20:00.000Z
testType
id5f87e63950d75e000a335aac
codeQUAD_BARE_MODULE_METROLOGY
name Quad Bare Module Metrology
stateactive
institution
id5d318624df98f200097386d5
codeANL
nameArgonne National Laboratory
user
id68755ce03942dab85ad88269
userIdentity4561-2270-1
firstNameEliza
middleName
lastNameHoward
runNumber69092ac246c81c946fe5f8bb
passedTrue
problemsFalse
properties
codenamedataTypevalueTyperequiredvaluerangeMinrangeMax
ANALYSIS_VERSIONAnalysis VersionstringsingleFalseNoneNoneNone
MEASUREMENT_DATEDate measurement performeddatetimeNoneFalseNoneNoneNone
MEASUREMENT_DURATIONMeasurement durationintegerNoneFalseNoneNoneNone
OPERATOR_IDENTITYOperator identitystringsingleFalseNoneNoneNone
results
codenamedataTypevalueTypearrayDimensionsadditionalvalueassociateChild
BARE_MODULE_THICKNESSAverage bare module thickness [µm]floatsingleNoneFalse333.3None
BARE_MODULE_THICKNESS_STD_DEVIATIONStd deviation of bare module thickness [µm]floatsingleNoneFalse4.4None
FECHIPS_XFE chips x dimension [mm]floatsingle1False42.22069None
FECHIPS_YFE chips y dimension [mm]floatsingle1False40.29603None
FECHIP_THICKNESSAverage FE chip thickness [µm]floatsingleNoneFalse163None
FECHIP_THICKNESS_STD_DEVIATIONStd deviation of FE chip thickness [µm]floatsingleNoneFalse3None
SENSOR_XSensor dimension in x [mm]floatsingleNoneFalse39.54577None
SENSOR_YSensor dimension in y [mm]floatsingleNoneFalse41.13523None
cts2025-11-07T19:47:22.634Z
sys
cts2025-11-07T19:47:22.634Z
mts2025-11-07T19:47:22.634Z
rev0
defects
commentsNone
attachments
components
idcodestatestateTsstateUserIdentitydummycompletedcompletedTscompletedUserIdentitytrashedtrashedTstrashedUserIdentityserialNumberalternativeIdentifierprojectsubprojectcomponentTypetypepropertiestestedAtStageinstitution
68d2c40ab5f1d1f55a7bf8646754a40a34aef40241068f9e8b9570fcready2025-09-23T16:00:10.896Z23-6780-1FalseFalseNoneNoneFalseNoneNone20UPGB43000296None
codeP
namePixels
codePG
namePixel general
codeBARE_MODULE
nameBare Module
codeQUAD_BARE_MODULE
nameQuad bare module
codenamedataTyperequireddefaultvaluecodeTable
FECHIP_VERSIONFE chip versioncodeTableTrueFalseITkpix_v2
codevalue
0RD53A
1ITkpix_v1
2ITkpix_v1.1
3ITkpix_v2
9No FE chip
SENSOR_TYPESensor TypecodeTableTrueFalseOuter pixel quad sensor tile
codevalue
0No sensor
1Market survey sensor tile
2L0 inner pixel 3D sensor tile
3L0 inner pixel planar sensor tile
4L1 inner pixel quad sensor tile
5Outer pixel quad sensor tile
9Dummy sensor tile
VENDORVendor codecodeTableTrueFalseAdvacam
codevalue
0Advacam
1Leonardo
2IZM
3HPK (in-kind)
4HPK (CERN order)
5RAL (in-house)
6Glasgow (in-house)
9ITk institute
codeBAREMODULERECEPTION
nameReception at ITk institute
order4
initialFalse
finalFalse
codeADVACAM
nameAdvacam Oy

 Current Stage: Post-Parylene Cold

Past QC Stages and Results

Post-Parylene Warm (MODULE/POST_PARYLENE_WARM)

Wirebond Protection (alt) (MODULE/WIREBOND_PROTECTION)

Parylene Unmasking (MODULE/PARYLENE_UNMASKING)

Parylene Coating (MODULE/PARYLENE_COATING)

Parylene Masking (MODULE/PARYLENE_MASKING)

Initial Cold (MODULE/INITIAL_COLD)

QC cross-check (module swapping) (MODULE/QC_CROSSCHECK)

Initial Warm (MODULE/INITIAL_WARM)

Wire Bonding (MODULE/WIREBONDING)

Bare module to module PCB assembly (MODULE/ASSEMBLY)

Initial state to associate flex to bare module (MODULE/INIT)

Reception at ITk institute (BAREMODULERECEPTION)

Test Local Result ProdDB Record
Sensor IV on bare module
(BARE_MODULE_SENSOR_IV)
No result N/A
Flatness
(FLATNESS)
No result N/A
Mass Measurement
(MASS_MEASUREMENT)
No result N/A
Quad Bare Module Metrology
(QUAD_BARE_MODULE_METROLOGY)
No result N/A
Single Bare Module Metrology
(SINGLE_BARE_MODULE_METROLOGY)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

GRAVEYARD - (unassembled) Bare Module impossible to recover (BAREMODULE/GRAVEYARD)

Not to be used for the detector (NOT_USED)

Bare module failed test, needs investigation (UNHAPPY)

Bare module assembly (BAREMODULEASSEMBLY)

LocalDB Test ID Stage Test Name Inspector Measurement Date Analysis Date Tags QC Registration
690e18…92f335 BAREMODULERECEPTION BARE_MODULE_SENSOR_IV ElizaHoward N/A 7 months ago No tags
69092a…e5f8bb BAREMODULERECEPTION QUAD_BARE_MODULE_METROLOGY ElizaHoward N/A 7 months ago No tags
68fbde…652566 BAREMODULERECEPTION MASS_MEASUREMENT ElizaHoward N/A 7 months ago No tags
690929…da24e2 BAREMODULERECEPTION VISUAL_INSPECTION ElizaHoward 7 months ago 7 months ago No tags
Stage Tests
BAREMODULEASSEMBLY
UNHAPPY
NOT_USED
BAREMODULE/GRAVEYARD
BAREMODULERECEPTION
  • Visual Inspection  (VISUAL_INSPECTION)
  • Mass Measurement  (MASS_MEASUREMENT)
  • Quad Bare Module Metrology  (QUAD_BARE_MODULE_METROLOGY)
  • Flatness  (FLATNESS)
  • Sensor IV on bare module  (BARE_MODULE_SENSOR_IV)
  • Single Bare Module Metrology  (SINGLE_BARE_MODULE_METROLOGY)
MODULE/INIT
MODULE/ASSEMBLY
MODULE/WIREBONDING
MODULE/INITIAL_WARM
MODULE/QC_CROSSCHECK
MODULE/INITIAL_COLD
MODULE/PARYLENE_MASKING
MODULE/PARYLENE_COATING
MODULE/PARYLENE_UNMASKING
MODULE/WIREBOND_PROTECTION
MODULE/POST_PARYLENE_WARM
MODULE/POST_PARYLENE_COLD
MODULE/THERMAL_CYCLES
MODULE/LONG_TERM_STABILITY_TEST
MODULE/FINAL_WARM
MODULE/FINAL_COLD
MODULE/FINAL_METROLOGY
MODULE/QC_STATUS
MODULE/UNHAPPY
MODULE/NOTCONSIDEREDINYIELDS
MODULE/GRAVEYARD
MODULE/COMPLETE
MODULE/RECEPTION
MODULE/TAB_CUTTING
LLS/PRE_TC_WARM
LLS/PRE_TC_COLD
LLS/POST_TC_WARM
LLS/POST_TC_COLD
LLS/RECEPTION
OB_LOADED_MODULE_CELL/INIT
OB_LOADED_MODULE_CELL/ASSEMBLY
OB_LOADED_MODULE_CELL/WIREBOND_PROTECTION
OB_LOADED_MODULE_CELL/THERMAL_CYCLES
OB_LOADED_MODULE_CELL/FINAL_WARM
OB_LOADED_MODULE_CELL/FINAL_COLD
OB_LOADED_MODULE_CELL/THERMAL_COLD
OB_LOADED_MODULE_CELL/THERMAL_WARM
OB_LOADED_MODULE_CELL/ENVELOPE_CHECK
OB_LOADED_MODULE_CELL/QC_STATUS
OB_LOADED_MODULE_CELL/UNHAPPY
OB_LOADED_MODULE_CELL/GRAVEYARD
OB_LOADED_MODULE_CELL/COMPLETE
OB_LOADED_MODULE_CELL/RECEPTION
OB_LOADED_MODULE_CELL/TAB_CUTTING
OB_LOADED_MODULE_CELL/PIGTAIL_INSERTION
Back to top page of this component