20UPGM23210863 (ANL_ITkPix_98)

MODULE/FINAL_METROLOGY

Component Information

Serial Number 20UPGM23210863
ProdDB ID  7fcbaa…3df57c
LocalDB ID 685081b9e85f5d0f12b347d4
Component Type MODULE
Parents No match.
Children 20UPGB43200173 Bare Module 20UPGFC0142449 FE Chip 20UPGFC0142389 FE Chip 20UPGFC0142489 FE Chip 20UPGFC0142516 FE Chip 20UPGPQ2210863 PCB
Flags
Distribution of chips on wafer

 Properties

Item Value
FE chip version 3
PCB-Bare Orientation isNormal True
Alternative ID ANL_ITkPix_98
Is preproduction module True
Wirebond protection roof presence None
Rank None

 Comments


Test: WIREBOND_PULL_TEST QC Passed

(Stage: MODULE/WIREBONDING)


Result of Wirebond Pull Test

Scan

Key Data
component id 685081b9e85f5d0f12b347d4
Stage MODULE/WIREBONDING
test Type WIREBOND_PULL_TEST
institute 64657cef8d79bac1f3f00578
user Simpson,Liana Rae

Result

Key Data
properties {'ANALYSIS_VERSION': 'in webApp', 'INSTRUMENT': 'Dage', 'MEASUREMENT_DATE': '2025-06-27T11:19Z', 'MEASUREMENT_DURATION': None, 'OPERATOR_IDENTITY': 'Tim Cundiff'} g
BOND_PEEL 0 g
DATA_UNAVAILABLE False g
HEEL_BREAKS_ON_FE_CHIP 100 g
HEEL_BREAKS_ON_PCB 0 g
LIFT_OFFS_LESS_THAN_7G 0 g
PULL_STRENGTH 8.962692 g
PULL_STRENGTH_DATA [[[8.7681, 2, 1], [9.1295, 2, 1], [8.8876, 2, 1], [9.029, 2, 1], [8.9172, 2, 1], [8.6918, 2, 1], [8.6867, 2, 1], [9.4692, 2, 1], [8.7869, 2, 1], [8.8008, 2, 1], [9.4255, 2, 2], [9.1155, 2, 2], [8.7104, 2, 2], [10.219, 2, 2], [9.1559, 2, 2], [9.1405, 2, 3], [9.5169, 2, 3], [9.366, 2, 3], [8.818, 2, 3], [8.4186, 2, 3], [8.7761, 2, 3], [8.9114, 2, 3], [8.5591, 2, 3], [8.6049, 2, 3], [8.1627, 2, 3]]] g
PULL_STRENGTH_ERROR 0.42054388784049634 g
PULL_STRENGTH_MAX 10.219 g
PULL_STRENGTH_MIN 8.1627 g
WIRE_BREAKS_5G 0 g
WIRE_PULLS 25 g

ProductionDB Record

id689cf7614352ea8e9ff76a7b
stateready
stateTs2025-08-13T20:36:49.713Z
stateUserIdentity1294-8027-1
date2025-07-15T20:26:00.000Z
testType
id63fb635d4069b50036d3faac
codeWIREBOND_PULL_TEST
nameWirebond pull test
stateactive
institution
id5d318624df98f200097386d5
codeANL
nameArgonne National Laboratory
user
id6797ca0f2ffbf908f24868f9
userIdentity1294-8027-1
firstNameSimpson,
middleName
lastNameLiana Rae
runNumber6876b96a2cb2a5e9814d1fee
passedTrue
problemsFalse
properties
codenamedataTypevalueTyperequiredvaluerangeMinrangeMax
ANALYSIS_VERSIONAnalysis VersionstringsingleFalsein webAppNoneNone
INSTRUMENTInstrumentstringsingleFalseDageNoneNone
MEASUREMENT_DATEDate measurement performeddatetimeNoneFalse2025-06-27T11:19ZNoneNone
MEASUREMENT_DURATIONMeasurement durationintegerNoneFalseNoneNoneNone
OPERATOR_IDENTITYOperator NamestringsingleFalseTim CundiffNoneNone
results
  • codeBOND_PEEL
    namePercentage of Lift Offs (i.e. bond peel) on FE chip or PCB [%]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value0
    associateChildNone
  • codeDATA_UNAVAILABLE
    nameData unavailable
    dataTypeboolean
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    valueFalse
    associateChildNone
  • codeHEEL_BREAKS_ON_FE_CHIP
    namePercentage of heel breaks on FE chips [%]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value100
    associateChildNone
  • codeHEEL_BREAKS_ON_PCB
    namePercentage of heel breaks on PCB [%]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value0
    associateChildNone
  • codeLIFT_OFFS_LESS_THAN_7G
    namePercentage of liftoffs < 7g [%]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value0
    associateChildNone
  • codePULL_STRENGTH
    nameMean pull strength [g]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value8.962692
    associateChildNone
  • codePULL_STRENGTH_DATA
    namePull strength data
    order1
    dataTypefloat
    valueTypearray
    arrayDimensions3
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value
        • 8.7681
        • 2
        • 1
        • 9.1295
        • 2
        • 1
        • 8.8876
        • 2
        • 1
        • 9.029
        • 2
        • 1
        • 8.9172
        • 2
        • 1
        • 8.6918
        • 2
        • 1
        • 8.6867
        • 2
        • 1
        • 9.4692
        • 2
        • 1
        • 8.7869
        • 2
        • 1
        • 8.8008
        • 2
        • 1
        • 9.4255
        • 2
        • 2
        • 9.1155
        • 2
        • 2
        • 8.7104
        • 2
        • 2
        • 10.219
        • 2
        • 2
        • 9.1559
        • 2
        • 2
        • 9.1405
        • 2
        • 3
        • 9.5169
        • 2
        • 3
        • 9.366
        • 2
        • 3
        • 8.818
        • 2
        • 3
        • 8.4186
        • 2
        • 3
        • 8.7761
        • 2
        • 3
        • 8.9114
        • 2
        • 3
        • 8.5591
        • 2
        • 3
        • 8.6049
        • 2
        • 3
        • 8.1627
        • 2
        • 3
    associateChildNone
  • codePULL_STRENGTH_ERROR
    nameStd deviation of pull strength [g]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value0.42054388784049634
    associateChildNone
  • codePULL_STRENGTH_MAX
    nameMaximum pull strength [g]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value10.219
    associateChildNone
  • codePULL_STRENGTH_MIN
    nameMinimum pull strength [g]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value8.1627
    associateChildNone
  • codeWIRE_BREAKS_5G
    nameNumber of wires breaking before 5g
    dataTypeinteger
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value0
    associateChildNone
  • codeWIRE_PULLS
    nameNumber of wires pulled
    dataTypeinteger
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value25
    associateChildNone
cts2025-08-13T20:36:49.713Z
sys
cts2025-08-13T20:36:49.713Z
mts2025-08-13T20:36:49.713Z
rev0
defects
commentsNone
attachments
components
idcodestatestateTsstateUserIdentitydummycompletedcompletedTscompletedUserIdentitytrashedtrashedTstrashedUserIdentityserialNumberalternativeIdentifierprojectsubprojectcomponentTypetypepropertiestestedAtStageinstitution
685081b9e85f5d0f12b347d47fcbaa44e176bcc705d80037423df57cready2025-06-16T20:42:33.524Z1294-8027-1FalseFalseNoneNoneFalseNoneNone20UPGM23210863ANL_ITkPix_98
codeP
namePixels
codePG
namePixel general
codeMODULE
nameModule
codeOUTER_SYSTEM_QUAD_MODULE
nameOuter system quad module
  • codeFECHIP_VERSION
    nameFE chip version
    dataTypecodeTable
    requiredTrue
    defaultFalse
    valueITkpix_v2
    codeTable
    codevalue
    0RD53A
    1ITkpix_v1
    2ITkpix_v1.1
    3ITkpix_v2
    9No FE chip
  • codeORIENTATION
    namePCB-Bare Orientation isNormal
    dataTypeboolean
    requiredTrue
    defaultFalse
    valueTrue
  • codeALTERNATIVE_IDENTIFIER
    nameAlternative ID
    dataTypestring
    requiredFalse
    defaultTrue
    valueANL_ITkPix_98
  • codeIS_PREPRODUCTION_MODULE
    nameIs preproduction module
    dataTypeboolean
    requiredFalse
    defaultFalse
    valueTrue
codeMODULE/WIREBONDING
nameWire Bonding
order2
initialFalse
finalFalse
codeANL
nameArgonne National Laboratory

 Current Stage: Final flatness measurement

Test Type Local Result
Flatness
(FLATNESS)
No TestRun!
Visual Inspection
(VISUAL_INSPECTION)
No TestRun!
IV measurement
(IV_MEASURE)
No TestRun!
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No TestRun!

 Candidate TestRuns of this Stage

LDB ID TestRun Code QC Passed Inspector Measurement Date Analysis Date Analysis Version Tags QC Registration
689cf4…32de01 VISUAL_INSPECTION Pass Simpson,Liana Rae 4 months ago 4 months ago 2.6.4 No tags Selected
6876b9…4d1fee WIREBOND_PULL_TEST Pass Simpson,Liana Rae N/A 4 months ago in webApp No tags Selected
687686…ee869b WIREBONDING Pass Simpson,Liana Rae N/A 4 months ago No tags Selected

Past QC Stages and Results

Final Cold (MODULE/FINAL_COLD)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Final Warm (MODULE/FINAL_WARM)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Long Term Stability Test (MODULE/LONG_TERM_STABILITY_TEST)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Longterm stability DCS
(LONG_TERM_STABILITY_DCS)
No result N/A

Thermal Cycles (MODULE/THERMAL_CYCLES)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
Flatness
(FLATNESS)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Thermal Cycling
(THERMAL_CYCLING)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Post-Parylene Cold (MODULE/POST_PARYLENE_COLD)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Post-Parylene Warm (MODULE/POST_PARYLENE_WARM)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered

Wirebond Protection (alt) (MODULE/WIREBOND_PROTECTION)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Mass Measurement
(MASS_MEASUREMENT)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
No result N/A
Wire bonding protection roof envelope
(WP_ENVELOPE)
No result N/A

Parylene Unmasking (MODULE/PARYLENE_UNMASKING)

Test Local Result ProdDB Record
Parylene (de-)masking
(DE_MASKING)
Registered Registered
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
Flatness
(FLATNESS)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered

Parylene Coating (MODULE/PARYLENE_COATING)

Test Local Result ProdDB Record
Parylene Properties
(PARYLENE)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered

Parylene Masking (MODULE/PARYLENE_MASKING)

Test Local Result ProdDB Record
Parylene (de-)masking
(DE_MASKING)
Registered Registered
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered

Initial Cold (MODULE/INITIAL_COLD)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A

QC cross-check (module swapping) (MODULE/QC_CROSSCHECK)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered

Initial Warm (MODULE/INITIAL_WARM)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered

Wire Bonding (MODULE/WIREBONDING)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered
Wirebond pull test
(WIREBOND_PULL_TEST)
Registered Registered
Wirebonding Information
(WIREBONDING)
Registered Registered

Bare module to module PCB assembly (MODULE/ASSEMBLY)

Test Local Result ProdDB Record
Flatness
(FLATNESS)
No result N/A
Glue Information Module+Flex Attach
(GLUE_MODULE_FLEX_ATTACH)
Registered Registered
Mass Measurement
(MASS_MEASUREMENT)
Registered Registered
Quad Module Metrology
(QUAD_MODULE_METROLOGY)
Registered Registered
Triplet Module Metrology
(TRIPLET_METROLOGY)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered

Initial state to associate flex to bare module (MODULE/INIT)

LocalDB Test ID Stage Test Name Inspector Measurement Date Analysis Date Tags QC Registration
68def1…93ee14 MODULE/FINAL_COLD IV_MEASURE GiordonStark 2 months ago 2 months ago No tags Selected
68e00c…93f30b MODULE/FINAL_COLD E_SUMMARY GiordonStark N/A 2 months ago No tags Selected
68deab…93e896 MODULE/FINAL_WARM IV_MEASURE GiordonStark 2 months ago 2 months ago No tags Selected
68deeb…93ede5 MODULE/FINAL_WARM E_SUMMARY GiordonStark N/A 2 months ago No tags Selected
68dea4…93e841 MODULE/THERMAL_CYCLES THERMAL_CYCLING GiordonStark 2 months ago 2 months ago No tags Selected
68d6fe…93d24c MODULE/POST_PARYLENE_WARM VISUAL_INSPECTION GiordonStark 3 months ago 2 months ago No tags Selected
68dd7a…93e33f MODULE/POST_PARYLENE_WARM IV_MEASURE GiordonStark 2 months ago 2 months ago No tags Selected
68ddbc…93e7f8 MODULE/POST_PARYLENE_WARM E_SUMMARY GiordonStark N/A 2 months ago No tags Selected
68d2ca…579fc1 MODULE/PARYLENE_UNMASKING DE_MASKING DanielAceves 3 months ago 3 months ago No tags Selected
68cc76…6c7174 MODULE/PARYLENE_UNMASKING VISUAL_INSPECTION DanielAceves 3 months ago 3 months ago No tags Selected
68c9c4…6c4733 MODULE/PARYLENE_COATING VISUAL_INSPECTION DavidJiang 3 months ago 3 months ago No tags Selected
68d2ca…579f92 MODULE/PARYLENE_COATING PARYLENE DavidJiang 3 months ago 3 months ago No tags Selected
68cc72…6c712f MODULE/PARYLENE_MASKING DE_MASKING DavidJiang 3 months ago 3 months ago No tags Selected
68c9b5…6c4578 MODULE/PARYLENE_MASKING VISUAL_INSPECTION DavidJiang 3 months ago 3 months ago No tags Selected
68d2c8…579f88 MODULE/QC_CROSSCHECK E_SUMMARY DanielAceves N/A 3 months ago No tags Selected
68d2c6…579bb9 MODULE/QC_CROSSCHECK IV_MEASURE DanielAceves 3 months ago 3 months ago No tags Selected
68c858…6c39b0 MODULE/INITIAL_WARM IV_MEASURE DavidJiang 3 months ago 3 months ago No tags Selected
68c859…6c3be4 MODULE/INITIAL_WARM E_SUMMARY DavidJiang N/A 3 months ago No tags Selected
689cf4…32de01 MODULE/WIREBONDING VISUAL_INSPECTION Simpson,Liana Rae 4 months ago 4 months ago No tags Selected
6876b9…4d1fee MODULE/WIREBONDING WIREBOND_PULL_TEST Simpson,Liana Rae N/A 4 months ago No tags Selected
687686…ee869b MODULE/WIREBONDING WIREBONDING Simpson,Liana Rae N/A 4 months ago No tags Selected
686c1a…fa6084 MODULE/ASSEMBLY QUAD_MODULE_METROLOGY Simpson,Liana Rae N/A 4 months ago No tags Selected
686bee…05c261 MODULE/ASSEMBLY VISUAL_INSPECTION Simpson,Liana Rae 5 months ago 4 months ago No tags Selected
6866fc…734a81 MODULE/ASSEMBLY GLUE_MODULE_FLEX_ATTACH Simpson,Liana Rae N/A 4 months ago No tags Selected
68659b…05bf65 MODULE/ASSEMBLY MASS_MEASUREMENT Simpson,Liana Rae 6 months ago 4 months ago No tags Selected
Stage Tests
MODULE/INIT
MODULE/ASSEMBLY
  • Mass Measurement  (MASS_MEASUREMENT)
  • Glue Information Module+Flex Attach  (GLUE_MODULE_FLEX_ATTACH)
  • Triplet Module Metrology  (TRIPLET_METROLOGY)
  • Visual Inspection  (VISUAL_INSPECTION)
  • Flatness  (FLATNESS)
  • Quad Module Metrology  (QUAD_MODULE_METROLOGY)
MODULE/WIREBONDING
  • Wirebonding Information  (WIREBONDING)
  • Wirebond pull test  (WIREBOND_PULL_TEST)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/INITIAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/QC_CROSSCHECK
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/INITIAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/PARYLENE_MASKING
  • Visual Inspection  (VISUAL_INSPECTION)
  • Parylene (de-)masking  (DE_MASKING)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/PARYLENE_COATING
  • Parylene Properties  (PARYLENE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/PARYLENE_UNMASKING
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Parylene (de-)masking  (DE_MASKING)
MODULE/WIREBOND_PROTECTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Wire bonding protection roof envelope  (WP_ENVELOPE)
  • Mass Measurement  (MASS_MEASUREMENT)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
MODULE/POST_PARYLENE_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/POST_PARYLENE_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/THERMAL_CYCLES
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Thermal Cycling  (THERMAL_CYCLING)
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
MODULE/LONG_TERM_STABILITY_TEST
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Longterm stability DCS  (LONG_TERM_STABILITY_DCS)
MODULE/FINAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/FINAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/FINAL_METROLOGY
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/QC_STATUS
  • Module ranking  (RANKING)
MODULE/UNHAPPY
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/NOTCONSIDEREDINYIELDS
MODULE/GRAVEYARD
MODULE/COMPLETE
MODULE/RECEPTION
  • Visual Inspection  (VISUAL_INSPECTION)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/TAB_CUTTING
  • Mass Measurement  (MASS_MEASUREMENT)
  • Module PCB Tab Cutting Information  (CUTTER_PCB_TAB)
  • Visual Inspection  (VISUAL_INSPECTION)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
LLS/PRE_TC_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/PRE_TC_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/POST_TC_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/POST_TC_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/RECEPTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
OB_LOADED_MODULE_CELL/INIT
OB_LOADED_MODULE_CELL/ASSEMBLY
OB_LOADED_MODULE_CELL/THERMAL_CYCLES
OB_LOADED_MODULE_CELL/FINAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/FINAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/THERMAL_COLD
  • Thermal Measure  (THERMAL_PERFORMANCE)
OB_LOADED_MODULE_CELL/THERMAL_WARM
  • Thermal Measure  (THERMAL_PERFORMANCE)
OB_LOADED_MODULE_CELL/ENVELOPE_CHECK
OB_LOADED_MODULE_CELL/QC_STATUS
OB_LOADED_MODULE_CELL/UNHAPPY
OB_LOADED_MODULE_CELL/COMPLETE
OB_LOADED_MODULE_CELL/RECEPTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/TAB_CUTTING
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Module PCB Tab Cutting Information  (CUTTER_PCB_TAB)
OB_LOADED_MODULE_CELL/PIGTAIL_INSERTION
Back to top page of this component