20UPGM23210861 (ANL_ITkPix_97)

MODULE/FINAL_METROLOGY

Component Information

Serial Number 20UPGM23210861
ProdDB ID  ed41ac…a0073c
LocalDB ID 6850812de85f5d0f12b345ce
Component Type MODULE
Parents No match.
Children 20UPGB43200172 Bare Module 20UPGFC0142155 FE Chip 20UPGFC0142188 FE Chip 20UPGFC0142202 FE Chip 20UPGFC0142168 FE Chip 20UPGPQ2210861 PCB
Flags
Distribution of chips on wafer

 Properties

Item Value
FE chip version 3
PCB-Bare Orientation isNormal True
Alternative ID ANL_ITkPix_97
Is preproduction module True
Wirebond protection roof presence None
Rank None

 Comments


Test: GLUE_MODULE_FLEX_ATTACH QC Passed

(Stage: MODULE/ASSEMBLY)


Basic View Only: custom view for this TestRun is not prepared.

Metadata

Key Data
QC Passed True
Date 4 months ago
component ObjectId 6850812de85f5d0f12b345ce
Stage MODULE/ASSEMBLY
Test Type GLUE_MODULE_FLEX_ATTACH
Institute ObjectId
User Name DanielAceves
ObjectId of this record 6866fca83942dab85a67c549
ObjectId of RAW record None
Tags No tags

Results

Key Data
BATCH_NUMBER ADJ0167300
CURE_TIME 24
GLUE_TYPE Epoxy
LOCATION_ASSEMBLY ANL
MEASUREMENT_DATE 2025-06-23T18:55:00Z
OPERATOR_IDENTITY Tim Cundiff
RATIO 0.5
TOOL_ID 37
TOOL_TYPE 1
HUMIDITY 52
TEMP 20

ProductionDB Record

id6890dd81a114c368964784ce
stateready
stateTs2025-08-04T16:19:13.800Z
stateUserIdentity4728-7541-1
date2025-07-03T21:56:00.000Z
testType
id5d13188702c38f00090aaad9
codeGLUE_MODULE_FLEX_ATTACH
nameGlue Information Module+Flex Attach
stateactive
institution
id5d318624df98f200097386d5
codeANL
nameArgonne National Laboratory
user
id6526ef19d2e4250042313864
userIdentity4728-7541-1
firstNameDaniel
middleName
lastNameAceves
runNumber6866fca83942dab85a67c549
passedTrue
problemsFalse
properties
  • codeBATCH_NUMBER
    nameGlue Batch Number
    dataTypestring
    valueTypesingle
    requiredTrue
    valueADJ0167300
  • codeCURE_TIME
    nameCure time [h]
    dataTypefloat
    valueTypeNone
    requiredFalse
    value24
    rangeMinNone
    rangeMaxNone
  • codeGLUE_TYPE
    nameGlue type
    dataTypestring
    valueTypesingle
    requiredTrue
    valueEpoxy
  • codeLOCATION_ASSEMBLY
    nameLocation of assembly
    dataTypestring
    valueTypeNone
    requiredFalse
    valueANL
    rangeMinNone
    rangeMaxNone
  • codeMEASUREMENT_DATE
    nameDate of assembly
    dataTypedatetime
    valueTypeNone
    requiredFalse
    value2025-06-23T18:55:00Z
    rangeMinNone
    rangeMaxNone
  • codeOPERATOR_IDENTITY
    nameOperator identity
    dataTypestring
    valueTypesingle
    requiredFalse
    valueTim Cundiff
    rangeMinNone
    rangeMaxNone
  • codeRATIO
    nameRatio of epoxy mixture
    dataTypefloat
    valueTypesingle
    requiredFalse
    value0.5
  • codeTOOL_ID
    nameTool ID
    dataTypeinteger
    valueTypesingle
    requiredFalse
    value37
    rangeMinNone
    rangeMaxNone
  • codeTOOL_TYPE
    nameTool type
    dataTypecodeTable
    valueTypesingle
    requiredFalse
    value1
    codeTable
    codevalue
    1Common
    2Japan
    3Oxford
    4triplet
results
codenameorderdataTypevalueTypeadditionalrangeMinrangeMaxvalueassociateChild
HUMIDITYHumidity (%)1floatsingleFalseNoneNone52None
TEMPRoom Temperature (C)1floatsingleFalseNoneNone20None
cts2025-08-04T16:19:13.800Z
sys
cts2025-08-04T16:19:13.800Z
mts2025-08-04T16:19:13.800Z
rev0
defects
commentsNone
attachments
components
idcodestatestateTsstateUserIdentitydummycompletedcompletedTscompletedUserIdentitytrashedtrashedTstrashedUserIdentityserialNumberalternativeIdentifierprojectsubprojectcomponentTypetypepropertiestestedAtStageinstitution
6850812de85f5d0f12b345ceed41acb97fafb2d25424939873a0073cready2025-06-16T20:40:13.552Z1294-8027-1FalseFalseNoneNoneFalseNoneNone20UPGM23210861ANL_ITkPix_97
codeP
namePixels
codePG
namePixel general
codeMODULE
nameModule
codeOUTER_SYSTEM_QUAD_MODULE
nameOuter system quad module
  • codeFECHIP_VERSION
    nameFE chip version
    dataTypecodeTable
    requiredTrue
    defaultFalse
    valueITkpix_v2
    codeTable
    codevalue
    0RD53A
    1ITkpix_v1
    2ITkpix_v1.1
    3ITkpix_v2
    9No FE chip
  • codeORIENTATION
    namePCB-Bare Orientation isNormal
    dataTypeboolean
    requiredTrue
    defaultFalse
    valueTrue
  • codeALTERNATIVE_IDENTIFIER
    nameAlternative ID
    dataTypestring
    requiredFalse
    defaultTrue
    valueANL_ITkPix_97
  • codeIS_PREPRODUCTION_MODULE
    nameIs preproduction module
    dataTypeboolean
    requiredFalse
    defaultFalse
    valueTrue
codeMODULE/ASSEMBLY
nameBare module to module PCB assembly
order1
initialFalse
finalFalse
codeANL
nameArgonne National Laboratory

 Current Stage: Final flatness measurement

Test Type Local Result
Flatness
(FLATNESS)
No TestRun!
Visual Inspection
(VISUAL_INSPECTION)
No TestRun!
IV measurement
(IV_MEASURE)
No TestRun!
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No TestRun!

 Candidate TestRuns of this Stage

LDB ID TestRun Code QC Passed Inspector Measurement Date Analysis Date Analysis Version Tags QC Registration
686c1a…9c3785 QUAD_MODULE_METROLOGY Pass DanielAceves N/A 4 months ago None No tags Selected
686bed…05c25f VISUAL_INSPECTION Pass DanielAceves 5 months ago 4 months ago 2.6.1 No tags Selected
6866fc…67c549 GLUE_MODULE_FLEX_ATTACH Pass DanielAceves N/A 4 months ago No tags Selected
68659b…05bf5f MASS_MEASUREMENT Pass DanielAceves 6 months ago 4 months ago 2.6.1 No tags Selected

Past QC Stages and Results

Final Cold (MODULE/FINAL_COLD)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Final Warm (MODULE/FINAL_WARM)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Long Term Stability Test (MODULE/LONG_TERM_STABILITY_TEST)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Longterm stability DCS
(LONG_TERM_STABILITY_DCS)
No result N/A

Thermal Cycles (MODULE/THERMAL_CYCLES)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
Flatness
(FLATNESS)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Thermal Cycling
(THERMAL_CYCLING)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Post-Parylene Cold (MODULE/POST_PARYLENE_COLD)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Post-Parylene Warm (MODULE/POST_PARYLENE_WARM)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered

Wirebond Protection (alt) (MODULE/WIREBOND_PROTECTION)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Mass Measurement
(MASS_MEASUREMENT)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
No result N/A
Wire bonding protection roof envelope
(WP_ENVELOPE)
No result N/A

Parylene Unmasking (MODULE/PARYLENE_UNMASKING)

Test Local Result ProdDB Record
Parylene (de-)masking
(DE_MASKING)
Registered Registered
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
Flatness
(FLATNESS)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Parylene Coating (MODULE/PARYLENE_COATING)

Test Local Result ProdDB Record
Parylene Properties
(PARYLENE)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered

Parylene Masking (MODULE/PARYLENE_MASKING)

Test Local Result ProdDB Record
Parylene (de-)masking
(DE_MASKING)
Registered Registered
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered

Initial Cold (MODULE/INITIAL_COLD)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A

QC cross-check (module swapping) (MODULE/QC_CROSSCHECK)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A

Initial Warm (MODULE/INITIAL_WARM)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered

Wire Bonding (MODULE/WIREBONDING)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered
Wirebond pull test
(WIREBOND_PULL_TEST)
Registered Registered
Wirebonding Information
(WIREBONDING)
Registered Registered

Bare module to module PCB assembly (MODULE/ASSEMBLY)

Test Local Result ProdDB Record
Flatness
(FLATNESS)
No result N/A
Glue Information Module+Flex Attach
(GLUE_MODULE_FLEX_ATTACH)
Registered Registered
Mass Measurement
(MASS_MEASUREMENT)
Registered Registered
Quad Module Metrology
(QUAD_MODULE_METROLOGY)
Registered Registered
Triplet Module Metrology
(TRIPLET_METROLOGY)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered

Initial state to associate flex to bare module (MODULE/INIT)

LocalDB Test ID Stage Test Name Inspector Measurement Date Analysis Date Tags QC Registration
68d2de…4a845d MODULE/FINAL_COLD IV_MEASURE GiordonStark 3 months ago 2 months ago No tags Selected
68d31d…4a88a7 MODULE/FINAL_COLD E_SUMMARY GiordonStark N/A 2 months ago No tags Selected
68d18e…30fd50 MODULE/FINAL_WARM IV_MEASURE GiordonStark 3 months ago 2 months ago No tags Selected
68d1d4…4a837c MODULE/FINAL_WARM E_SUMMARY GiordonStark N/A 2 months ago No tags Selected
68cc41…30f0b0 MODULE/THERMAL_CYCLES THERMAL_CYCLING GiordonStark 3 months ago 2 months ago No tags Selected
68a368…f1bf39 MODULE/POST_PARYLENE_WARM VISUAL_INSPECTION GiordonStark 4 months ago 2 months ago No tags Selected
68bf26…30dc8a MODULE/POST_PARYLENE_WARM IV_MEASURE GiordonStark 3 months ago 2 months ago No tags Selected
68bf5b…30e12e MODULE/POST_PARYLENE_WARM E_SUMMARY GiordonStark N/A 2 months ago No tags Selected
689ce0…ed3b37 MODULE/PARYLENE_UNMASKING DE_MASKING Simpson,Liana Rae N/A 4 months ago No tags Selected
689ce0…f60a7f MODULE/PARYLENE_COATING PARYLENE Simpson,Liana Rae N/A 4 months ago No tags Selected
689cd7…32d018 MODULE/PARYLENE_COATING VISUAL_INSPECTION Simpson,Liana Rae 4 months ago 4 months ago No tags Selected
689b89…32cf24 MODULE/PARYLENE_MASKING DE_MASKING Simpson,Liana Rae 4 months ago 4 months ago No tags Selected
689b8c…32cf3c MODULE/PARYLENE_MASKING VISUAL_INSPECTION Simpson,Liana Rae 4 months ago 4 months ago No tags Selected
68911e…329d85 MODULE/INITIAL_WARM IV_MEASURE DanielAceves 4 months ago 4 months ago No tags Selected
689124…32a5ce MODULE/INITIAL_WARM E_SUMMARY DanielAceves N/A 4 months ago No tags Selected
688cf7…051716 MODULE/WIREBONDING VISUAL_INSPECTION DanielAceves 4 months ago 4 months ago No tags Selected
6876b9…e38a6c MODULE/WIREBONDING WIREBOND_PULL_TEST DanielAceves N/A 4 months ago No tags Selected
687686…e2fd61 MODULE/WIREBONDING WIREBONDING DanielAceves N/A 4 months ago No tags Selected
686c1a…9c3785 MODULE/ASSEMBLY QUAD_MODULE_METROLOGY DanielAceves N/A 4 months ago No tags Selected
686bed…05c25f MODULE/ASSEMBLY VISUAL_INSPECTION DanielAceves 5 months ago 4 months ago No tags Selected
6866fc…67c549 MODULE/ASSEMBLY GLUE_MODULE_FLEX_ATTACH DanielAceves N/A 4 months ago No tags Selected
68659b…05bf5f MODULE/ASSEMBLY MASS_MEASUREMENT DanielAceves 6 months ago 4 months ago No tags Selected
Stage Tests
MODULE/INIT
MODULE/ASSEMBLY
  • Mass Measurement  (MASS_MEASUREMENT)
  • Glue Information Module+Flex Attach  (GLUE_MODULE_FLEX_ATTACH)
  • Triplet Module Metrology  (TRIPLET_METROLOGY)
  • Visual Inspection  (VISUAL_INSPECTION)
  • Flatness  (FLATNESS)
  • Quad Module Metrology  (QUAD_MODULE_METROLOGY)
MODULE/WIREBONDING
  • Wirebonding Information  (WIREBONDING)
  • Wirebond pull test  (WIREBOND_PULL_TEST)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/INITIAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/QC_CROSSCHECK
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/INITIAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/PARYLENE_MASKING
  • Visual Inspection  (VISUAL_INSPECTION)
  • Parylene (de-)masking  (DE_MASKING)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/PARYLENE_COATING
  • Parylene Properties  (PARYLENE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/PARYLENE_UNMASKING
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Parylene (de-)masking  (DE_MASKING)
MODULE/WIREBOND_PROTECTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Wire bonding protection roof envelope  (WP_ENVELOPE)
  • Mass Measurement  (MASS_MEASUREMENT)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
MODULE/POST_PARYLENE_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/POST_PARYLENE_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/THERMAL_CYCLES
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Thermal Cycling  (THERMAL_CYCLING)
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
MODULE/LONG_TERM_STABILITY_TEST
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Longterm stability DCS  (LONG_TERM_STABILITY_DCS)
MODULE/FINAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/FINAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/FINAL_METROLOGY
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/QC_STATUS
  • Module ranking  (RANKING)
MODULE/UNHAPPY
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/NOTCONSIDEREDINYIELDS
MODULE/GRAVEYARD
MODULE/COMPLETE
MODULE/RECEPTION
  • Visual Inspection  (VISUAL_INSPECTION)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/TAB_CUTTING
  • Mass Measurement  (MASS_MEASUREMENT)
  • Module PCB Tab Cutting Information  (CUTTER_PCB_TAB)
  • Visual Inspection  (VISUAL_INSPECTION)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
LLS/PRE_TC_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/PRE_TC_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/POST_TC_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/POST_TC_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/RECEPTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
OB_LOADED_MODULE_CELL/INIT
OB_LOADED_MODULE_CELL/ASSEMBLY
OB_LOADED_MODULE_CELL/THERMAL_CYCLES
OB_LOADED_MODULE_CELL/FINAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/FINAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/THERMAL_COLD
  • Thermal Measure  (THERMAL_PERFORMANCE)
OB_LOADED_MODULE_CELL/THERMAL_WARM
  • Thermal Measure  (THERMAL_PERFORMANCE)
OB_LOADED_MODULE_CELL/ENVELOPE_CHECK
OB_LOADED_MODULE_CELL/QC_STATUS
OB_LOADED_MODULE_CELL/UNHAPPY
OB_LOADED_MODULE_CELL/COMPLETE
OB_LOADED_MODULE_CELL/RECEPTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/TAB_CUTTING
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Module PCB Tab Cutting Information  (CUTTER_PCB_TAB)
OB_LOADED_MODULE_CELL/PIGTAIL_INSERTION
Back to top page of this component