20UPGM23210331 (ANL_ITkPix_88)

MODULE/POST_PARYLENE_WARM

Component Information

Serial Number 20UPGM23210331
ProdDB ID  2858f4…ff3fcb
LocalDB ID 68507c89e85f5d0f12b32eec
Component Type MODULE
Parents No match.
Children 20UPGB43200163 Bare Module 20UPGPQ2210331 PCB 20UPGFC0142154 FE Chip 20UPGFC0142187 FE Chip 20UPGFC0142182 FE Chip 20UPGFC0142220 FE Chip 20UPGB43200163 Bare Module 20UPGFC0142154 FE Chip 20UPGPQ2210331 PCB 20UPGFC0142187 FE Chip 20UPGFC0142182 FE Chip 20UPGFC0142220 FE Chip
Flags • FE chip 3 – no communication • FE chip 4 – no communication • Problematic core column (can't be masked with current tool)
Distribution of chips on wafer

 Properties

Item Value
FE chip version 3
PCB-Bare Orientation isNormal True
Is preproduction module True
Alternative ID ANL_ITkPix_88
Wirebond protection roof presence None
Rank None

 Comments


Test: WIREBOND_PULL_TEST QC Passed

(Stage: MODULE/WIREBONDING)


Result of Wirebond Pull Test

Scan

Key Data
component id 68507c89e85f5d0f12b32eec
Stage MODULE/WIREBONDING
test Type WIREBOND_PULL_TEST
institute 64657cef8d79bac1f3f00578
user DanielAceves

Result

Key Data
properties {'ANALYSIS_VERSION': 'in webApp', 'INSTRUMENT': 'Dage', 'MEASUREMENT_DATE': '2025-06-19T13:39Z', 'MEASUREMENT_DURATION': None, 'OPERATOR_IDENTITY': 'Tim Cundiff'} g
BOND_PEEL 0 g
DATA_UNAVAILABLE False g
HEEL_BREAKS_ON_FE_CHIP 100 g
HEEL_BREAKS_ON_PCB 0 g
LIFT_OFFS_LESS_THAN_7G 0 g
PULL_STRENGTH 9.7244 g
PULL_STRENGTH_DATA [[[9.664, 2, 1], [10, 2, 1], [9.5323, 2, 1], [9.7734, 2, 1], [9.3897, 2, 1], [10.22, 2, 1], [10.143, 2, 1], [9.5862, 2, 1], [10.047, 2, 1], [10.346, 2, 1], [9.5857, 2, 2], [8.6766, 2, 2], [9.8276, 2, 2], [9.2386, 2, 2], [9.1685, 2, 2], [10.302, 2, 3], [9.6111, 2, 3], [10.256, 2, 3], [9.9186, 2, 3], [9.8401, 2, 3], [10.075, 2, 3], [9.56, 2, 3], [9.1194, 2, 3], [9.2764, 2, 3], [9.9528, 2, 3]]] g
PULL_STRENGTH_ERROR 0.4224498362725054 g
PULL_STRENGTH_MAX 10.346 g
PULL_STRENGTH_MIN 8.6766 g
WIRE_BREAKS_5G 0 g
WIRE_PULLS 25 g

ProductionDB Record

id688a44d00f647c459c6a6172
stateready
stateTs2025-07-30T16:14:08.707Z
stateUserIdentity4728-7541-1
date2025-07-15T20:24:00.000Z
testType
id63fb635d4069b50036d3faac
codeWIREBOND_PULL_TEST
nameWirebond pull test
stateactive
institution
id5d318624df98f200097386d5
codeANL
nameArgonne National Laboratory
user
id6526ef19d2e4250042313864
userIdentity4728-7541-1
firstNameDaniel
middleName
lastNameAceves
runNumber6876b9022cb2a5e9814d1f2e
passedTrue
problemsFalse
properties
codenamedataTypevalueTyperequiredvaluerangeMinrangeMax
ANALYSIS_VERSIONAnalysis VersionstringsingleFalsein webAppNoneNone
INSTRUMENTInstrumentstringsingleFalseDageNoneNone
MEASUREMENT_DATEDate measurement performeddatetimeNoneFalse2025-06-19T13:39ZNoneNone
MEASUREMENT_DURATIONMeasurement durationintegerNoneFalseNoneNoneNone
OPERATOR_IDENTITYOperator NamestringsingleFalseTim CundiffNoneNone
results
  • codeBOND_PEEL
    namePercentage of Lift Offs (i.e. bond peel) on FE chip or PCB [%]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value0
    associateChildNone
  • codeDATA_UNAVAILABLE
    nameData unavailable
    dataTypeboolean
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    valueFalse
    associateChildNone
  • codeHEEL_BREAKS_ON_FE_CHIP
    namePercentage of heel breaks on FE chips [%]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value100
    associateChildNone
  • codeHEEL_BREAKS_ON_PCB
    namePercentage of heel breaks on PCB [%]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value0
    associateChildNone
  • codeLIFT_OFFS_LESS_THAN_7G
    namePercentage of liftoffs < 7g [%]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value0
    associateChildNone
  • codePULL_STRENGTH
    nameMean pull strength [g]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value9.7244
    associateChildNone
  • codePULL_STRENGTH_DATA
    namePull strength data
    order1
    dataTypefloat
    valueTypearray
    arrayDimensions3
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value
        • 9.664
        • 2
        • 1
        • 10
        • 2
        • 1
        • 9.5323
        • 2
        • 1
        • 9.7734
        • 2
        • 1
        • 9.3897
        • 2
        • 1
        • 10.22
        • 2
        • 1
        • 10.143
        • 2
        • 1
        • 9.5862
        • 2
        • 1
        • 10.047
        • 2
        • 1
        • 10.346
        • 2
        • 1
        • 9.5857
        • 2
        • 2
        • 8.6766
        • 2
        • 2
        • 9.8276
        • 2
        • 2
        • 9.2386
        • 2
        • 2
        • 9.1685
        • 2
        • 2
        • 10.302
        • 2
        • 3
        • 9.6111
        • 2
        • 3
        • 10.256
        • 2
        • 3
        • 9.9186
        • 2
        • 3
        • 9.8401
        • 2
        • 3
        • 10.075
        • 2
        • 3
        • 9.56
        • 2
        • 3
        • 9.1194
        • 2
        • 3
        • 9.2764
        • 2
        • 3
        • 9.9528
        • 2
        • 3
    associateChildNone
  • codePULL_STRENGTH_ERROR
    nameStd deviation of pull strength [g]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value0.4224498362725054
    associateChildNone
  • codePULL_STRENGTH_MAX
    nameMaximum pull strength [g]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value10.346
    associateChildNone
  • codePULL_STRENGTH_MIN
    nameMinimum pull strength [g]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value8.6766
    associateChildNone
  • codeWIRE_BREAKS_5G
    nameNumber of wires breaking before 5g
    dataTypeinteger
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value0
    associateChildNone
  • codeWIRE_PULLS
    nameNumber of wires pulled
    dataTypeinteger
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value25
    associateChildNone
cts2025-07-30T16:14:08.707Z
sys
cts2025-07-30T16:14:08.707Z
mts2025-07-30T16:14:08.707Z
rev0
defects
commentsNone
attachments
components
idcodestatestateTsstateUserIdentitydummycompletedcompletedTscompletedUserIdentitytrashedtrashedTstrashedUserIdentityserialNumberalternativeIdentifierprojectsubprojectcomponentTypetypepropertiestestedAtStageinstitution
68507c89e85f5d0f12b32eec2858f400b6c130523e6e0d4bb9ff3fcbready2025-06-16T20:20:25.603Z4728-7541-1FalseFalseNoneNoneFalseNoneNone20UPGM23210331ANL_ITkPix_88
codeP
namePixels
codePG
namePixel general
codeMODULE
nameModule
codeOUTER_SYSTEM_QUAD_MODULE
nameOuter system quad module
  • codeFECHIP_VERSION
    nameFE chip version
    dataTypecodeTable
    requiredTrue
    defaultFalse
    valueITkpix_v2
    codeTable
    codevalue
    0RD53A
    1ITkpix_v1
    2ITkpix_v1.1
    3ITkpix_v2
    9No FE chip
  • codeORIENTATION
    namePCB-Bare Orientation isNormal
    dataTypeboolean
    requiredTrue
    defaultFalse
    valueTrue
  • codeIS_PREPRODUCTION_MODULE
    nameIs preproduction module
    dataTypeboolean
    requiredFalse
    defaultFalse
    valueTrue
  • codeALTERNATIVE_IDENTIFIER
    nameAlternative ID
    dataTypestring
    requiredFalse
    defaultTrue
    valueANL_ITkPix_88
codeMODULE/WIREBONDING
nameWire Bonding
order2
initialFalse
finalFalse
codeANL
nameArgonne National Laboratory

 Current Stage: Post-Parylene Warm

Test Type Local Result
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No TestRun!
IV measurement
(IV_MEASURE)
TestRun Present
Visual Inspection
(VISUAL_INSPECTION)
TestRun Present

 Candidate TestRuns of this Stage

LDB ID TestRun Code QC Passed Inspector Measurement Date Analysis Date Analysis Version Tags QC Registration
687818…258ede VISUAL_INSPECTION Pass DanielAceves 5 months ago 5 months ago 2.6.3 No tags Selected
6876b9…4d1f2e WIREBOND_PULL_TEST Pass DanielAceves N/A 5 months ago in webApp No tags Selected
687686…e2faf7 WIREBONDING Pass DanielAceves N/A 5 months ago No tags Selected

Past QC Stages and Results

Wirebond Protection (alt) (MODULE/WIREBOND_PROTECTION)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Mass Measurement
(MASS_MEASUREMENT)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
No result N/A
Wire bonding protection roof envelope
(WP_ENVELOPE)
No result N/A

Parylene Unmasking (MODULE/PARYLENE_UNMASKING)

Test Local Result ProdDB Record
Parylene (de-)masking
(DE_MASKING)
No result N/A
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
Flatness
(FLATNESS)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered

Parylene Coating (MODULE/PARYLENE_COATING)

Test Local Result ProdDB Record
Parylene Properties
(PARYLENE)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered

Parylene Masking (MODULE/PARYLENE_MASKING)

Test Local Result ProdDB Record
Parylene (de-)masking
(DE_MASKING)
No result N/A
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered

Initial Cold (MODULE/INITIAL_COLD)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A

QC cross-check (module swapping) (MODULE/QC_CROSSCHECK)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A

Initial Warm (MODULE/INITIAL_WARM)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered

Wire Bonding (MODULE/WIREBONDING)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered
Wirebond pull test
(WIREBOND_PULL_TEST)
Registered Registered
Wirebonding Information
(WIREBONDING)
Registered Registered

Bare module to module PCB assembly (MODULE/ASSEMBLY)

Test Local Result ProdDB Record
Flatness
(FLATNESS)
No result N/A
Glue Information Module+Flex Attach
(GLUE_MODULE_FLEX_ATTACH)
Registered Registered
Mass Measurement
(MASS_MEASUREMENT)
Registered Registered
Quad Module Metrology
(QUAD_MODULE_METROLOGY)
Registered Registered
Triplet Module Metrology
(TRIPLET_METROLOGY)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered

Initial state to associate flex to bare module (MODULE/INIT)

LocalDB Test ID Stage Test Name Inspector Measurement Date Analysis Date Tags QC Registration
693caf…5f36be MODULE/POST_PARYLENE_WARM IV_MEASURE None 6 days ago 6 days ago ganymede_4 Selected
693ca4…5f36b4 MODULE/POST_PARYLENE_WARM IV_MEASURE None 6 days ago 6 days ago ganymede_4
692e3a…a2cec2 MODULE/POST_PARYLENE_WARM IV_MEASURE None 2 weeks ago 2 weeks ago ganymede_4
68dafa…d41b28 MODULE/POST_PARYLENE_WARM VISUAL_INSPECTION None 3 months ago 3 months ago No tags Selected
68c9cd…6c48b6 MODULE/PARYLENE_UNMASKING VISUAL_INSPECTION Simpson,Liana Rae 3 months ago 3 months ago No tags Selected
68c9bd…6c4605 MODULE/PARYLENE_COATING VISUAL_INSPECTION Simpson,Liana Rae 3 months ago 3 months ago No tags Selected
68c9b2…6c4557 MODULE/PARYLENE_MASKING VISUAL_INSPECTION Simpson,Liana Rae 3 months ago 3 months ago No tags Selected
688a49…7d161f MODULE/INITIAL_WARM IV_MEASURE DanielAceves 5 months ago 5 months ago No tags Selected
688bac…7d1fa0 MODULE/INITIAL_WARM E_SUMMARY DanielAceves N/A 5 months ago No tags Selected
687818…258ede MODULE/WIREBONDING VISUAL_INSPECTION DanielAceves 5 months ago 5 months ago No tags Selected
6876b9…4d1f2e MODULE/WIREBONDING WIREBOND_PULL_TEST DanielAceves N/A 5 months ago No tags Selected
687686…e2faf7 MODULE/WIREBONDING WIREBONDING DanielAceves N/A 5 months ago No tags Selected
686c17…fa5747 MODULE/ASSEMBLY QUAD_MODULE_METROLOGY DanielAceves N/A 5 months ago No tags Selected
6866f4…05c24f MODULE/ASSEMBLY VISUAL_INSPECTION DanielAceves 5 months ago 5 months ago No tags Selected
6866fc…67c4c9 MODULE/ASSEMBLY GLUE_MODULE_FLEX_ATTACH DanielAceves N/A 5 months ago No tags Selected
68657f…05be16 MODULE/ASSEMBLY MASS_MEASUREMENT DanielAceves 6 months ago 5 months ago No tags Selected
Stage Tests
MODULE/INIT
MODULE/ASSEMBLY
  • Mass Measurement  (MASS_MEASUREMENT)
  • Glue Information Module+Flex Attach  (GLUE_MODULE_FLEX_ATTACH)
  • Triplet Module Metrology  (TRIPLET_METROLOGY)
  • Visual Inspection  (VISUAL_INSPECTION)
  • Flatness  (FLATNESS)
  • Quad Module Metrology  (QUAD_MODULE_METROLOGY)
MODULE/WIREBONDING
  • Wirebonding Information  (WIREBONDING)
  • Wirebond pull test  (WIREBOND_PULL_TEST)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/INITIAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/QC_CROSSCHECK
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/INITIAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/PARYLENE_MASKING
  • Visual Inspection  (VISUAL_INSPECTION)
  • Parylene (de-)masking  (DE_MASKING)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/PARYLENE_COATING
  • Parylene Properties  (PARYLENE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/PARYLENE_UNMASKING
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Parylene (de-)masking  (DE_MASKING)
MODULE/WIREBOND_PROTECTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Wire bonding protection roof envelope  (WP_ENVELOPE)
  • Mass Measurement  (MASS_MEASUREMENT)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
MODULE/POST_PARYLENE_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/POST_PARYLENE_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/THERMAL_CYCLES
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Thermal Cycling  (THERMAL_CYCLING)
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
MODULE/LONG_TERM_STABILITY_TEST
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Longterm stability DCS  (LONG_TERM_STABILITY_DCS)
MODULE/FINAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/FINAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/FINAL_METROLOGY
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/QC_STATUS
  • Module ranking  (RANKING)
MODULE/UNHAPPY
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/NOTCONSIDEREDINYIELDS
MODULE/GRAVEYARD
MODULE/COMPLETE
MODULE/RECEPTION
  • Visual Inspection  (VISUAL_INSPECTION)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/TAB_CUTTING
  • Mass Measurement  (MASS_MEASUREMENT)
  • Module PCB Tab Cutting Information  (CUTTER_PCB_TAB)
  • Visual Inspection  (VISUAL_INSPECTION)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
LLS/PRE_TC_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/PRE_TC_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/POST_TC_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/POST_TC_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/RECEPTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
OB_LOADED_MODULE_CELL/INIT
OB_LOADED_MODULE_CELL/ASSEMBLY
OB_LOADED_MODULE_CELL/THERMAL_CYCLES
OB_LOADED_MODULE_CELL/FINAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/FINAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/THERMAL_COLD
  • Thermal Measure  (THERMAL_PERFORMANCE)
OB_LOADED_MODULE_CELL/THERMAL_WARM
  • Thermal Measure  (THERMAL_PERFORMANCE)
OB_LOADED_MODULE_CELL/ENVELOPE_CHECK
OB_LOADED_MODULE_CELL/QC_STATUS
OB_LOADED_MODULE_CELL/UNHAPPY
OB_LOADED_MODULE_CELL/COMPLETE
OB_LOADED_MODULE_CELL/RECEPTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/TAB_CUTTING
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Module PCB Tab Cutting Information  (CUTTER_PCB_TAB)
OB_LOADED_MODULE_CELL/PIGTAIL_INSERTION
Back to top page of this component