20UPGB13200054

MODULE/QC_CROSSCHECK

Component Information

Serial Number 20UPGB13200054
ProdDB ID  c823dd…501710
LocalDB ID 683ef91c9f4d7e6ede6db144
Component Type BARE_MODULE
Parents 20UPIM54304211
Children 20UPGFC0145251 FE Chip 20UPIS17100340 Sensor Tile
Flags
Distribution of chips on wafer

 Properties

Item Value
FE chip version readonly 3
Sensor Type 2
Vendor code readonly 2
Thickness of FE chips (RD53A) None

 Comments


Test: SINGLE_BARE_MODULE_METROLOGY QC Failed

(Stage: BAREMODULERECEPTION)


Basic View Only: custom view for this TestRun is not prepared.

Metadata

Key Data
QC Passed False
Date 3 months ago
component ObjectId 683ef91c9f4d7e6ede6db144
Stage BAREMODULERECEPTION
Test Type SINGLE_BARE_MODULE_METROLOGY
Institute ObjectId
User Name RiccardoZanzottera
ObjectId of this record 68c7e29a1a8dab767bfceb41
ObjectId of RAW record None
Tags No tags

Results

Key Data
ANALYSIS_VERSION mqat vNone
BARE_MODULE_HEIGHT 21.203
BARE_MODULE_THICKNESS 0.43502
BARE_MODULE_THICKNESS_RANGE [0.4156, 0.4476]
FECHIP_THICKNESS 0.14129999999999998
FECHIP_THICKNESS_RANGE [0.1299, 0.1527]
FM_TO_FE_LEFTEDGE 0.099
FM_TO_FE_RIGHTEDGE 0.107
FM_TO_SENSOR_LEFTEDGE 0.273
FM_TO_SENSOR_RIGHTEDGE 0.215
LENGTH_PRECISION 0.001
SENSOR_X 20.38
SENSOR_Y 19.597

ProductionDB Record

id68c7e29a1a8dab767bfceb41
stateready
stateTs2025-09-15T09:55:38.877Z
stateUserIdentity1237-9341-1
date2025-09-12T10:42:26.240Z
testType
id65ef2e1657a6a40035a71465
codeSINGLE_BARE_MODULE_METROLOGY
nameSingle Bare Module Metrology
stateactive
institution
id5d41d8ddf6e07b000a559aee
codeINFN_MILANO
nameINFN Milano
user
id64b11615df91d20042b5df92
userIdentity1237-9341-1
firstNameRiccardo
middleName
lastNameZanzottera
runNumber1
passedFalse
problemsFalse
properties
codenamedataTypevalueTyperequiredvaluerangeMinrangeMax
ANALYSIS_VERSIONAnalysis VersionstringsingleFalseNoneNoneNone
results
codenamedataTypevalueTypearrayDimensionsadditionalrangeMinrangeMaxvalueassociateChild
BARE_MODULE_HEIGHTMax bare module height [mm]floatsingleNoneFalse-131.21521.203None
BARE_MODULE_THICKNESSAverage bare module thickness [mm]floatsingleNoneFalseNoneNone0.43502None
BARE_MODULE_THICKNESS_RANGERange of bare module thickness [mm]floatarray1FalseNoneNone
  • 0.4156
  • 0.4476
None
FECHIP_THICKNESSAverage FE chip thickness [mm]floatsingleNoneFalse-110.14129999999999998None
FECHIP_THICKNESS_RANGERange of FE chip thickness [mm]floatarray1FalseNoneNone
  • 0.1299
  • 0.1527
None
FM_TO_FE_LEFTEDGEFM to FE left edge [mm]floatsingleNoneFalse0.010.220.099None
FM_TO_FE_RIGHTEDGEFM to FE right edge [mm]floatsingleNoneFalseNoneNone0.107None
FM_TO_SENSOR_LEFTEDGEFM to Sensor left edge [mm]floatsingleNoneFalseNoneNone0.273None
FM_TO_SENSOR_RIGHTEDGEFM to Sensor right edge [mm]floatsingleNoneFalseNoneNone0.215None
LENGTH_PRECISIONLength Precision [mm]floatsingleNoneFalseNoneNone0.001None
SENSOR_XMax Sensor X [mm]floatsingleNoneFalse-13020.38None
SENSOR_YMax Sensor Y [mm]floatsingleNoneFalse-13019.597None
cts2025-09-15T09:55:38.877Z
sys
cts2025-09-15T09:55:38.877Z
mts2025-09-15T09:55:38.877Z
rev0
defects
commentsNone
attachments
components
idcodestatestateTsstateUserIdentitydummycompletedcompletedTscompletedUserIdentitytrashedtrashedTstrashedUserIdentityserialNumberalternativeIdentifierprojectsubprojectcomponentTypetypepropertiestestedAtStageinstitution
683ef91c9f4d7e6ede6db144c823dd8bce0a736746f6757874501710ready2025-06-03T13:31:08.543Z23-6780-1FalseFalseNoneNoneFalseNoneNone20UPGB13200054None
codeP
namePixels
codePG
namePixel general
codeBARE_MODULE
nameBare Module
codeSINGLE_BARE_MODULE
nameSingle bare module
codenamedataTyperequireddefaultvaluecodeTable
FECHIP_VERSIONFE chip versioncodeTableTrueFalseITkpix_v2
codevalue
0RD53A
1ITkpix_v1
2ITkpix_v1.1
3ITkpix_v2
9No FE chip
SENSOR_TYPESensor TypecodeTableTrueFalseL0 inner pixel 3D sensor tile
codevalue
0No sensor
1Market survey sensor tile
2L0 inner pixel 3D sensor tile
3L0 inner pixel planar sensor tile
4L1 inner pixel quad sensor tile
5Outer pixel quad sensor tile
9Dummy sensor tile
VENDORVendor codecodeTableTrueFalseIZM
codevalue
0Advacam
1Leonardo
2IZM
3HPK (in-kind)
4HPK (CERN order)
5RAL (in-house)
6Glasgow (in-house)
9ITk institute
codeBAREMODULERECEPTION
nameReception at ITk institute
order3
initialFalse
finalFalse
codeIZM
nameFraunhofer-Institut für Zuverlässigkeit und Mikrointegration (IZM)

 Current Stage: QC cross-check (module swapping)

Past QC Stages and Results

Initial Warm (MODULE/INITIAL_WARM)

Wire Bonding (MODULE/WIREBONDING)

Bare module to module PCB assembly (MODULE/ASSEMBLY)

Initial state to associate flex to bare module (MODULE/INIT)

Reception at ITk institute (BAREMODULERECEPTION)

Test Local Result ProdDB Record
Sensor IV on bare module
(BARE_MODULE_SENSOR_IV)
Registered Registered
Flatness
(FLATNESS)
No result N/A
Mass Measurement
(MASS_MEASUREMENT)
No result N/A
Quad Bare Module Metrology
(QUAD_BARE_MODULE_METROLOGY)
No result N/A
Single Bare Module Metrology
(SINGLE_BARE_MODULE_METROLOGY)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered

Not to be used for the detector (NOT_USED)

Bare module failed test, needs investigation (UNHAPPY)

Bare module assembly (BAREMODULEASSEMBLY)

LocalDB Test ID Stage Test Name Inspector Measurement Date Analysis Date Tags QC Registration
68c7e2…fceb41 BAREMODULERECEPTION SINGLE_BARE_MODULE_METROLOGY RiccardoZanzottera N/A 3 months ago No tags Selected
6888fe…0567a2 BAREMODULERECEPTION BARE_MODULE_SENSOR_IV AnnaRaquel Petri N/A 5 months ago No tags
686ce5…016486 BAREMODULERECEPTION BARE_MODULE_SENSOR_IV ClaudiaGemme N/A 5 months ago No tags Selected
Stage Tests
BAREMODULEASSEMBLY
UNHAPPY
NOT_USED
BAREMODULERECEPTION
  • Visual Inspection  (VISUAL_INSPECTION)
  • Mass Measurement  (MASS_MEASUREMENT)
  • Quad Bare Module Metrology  (QUAD_BARE_MODULE_METROLOGY)
  • Flatness  (FLATNESS)
  • Sensor IV on bare module  (BARE_MODULE_SENSOR_IV)
  • Single Bare Module Metrology  (SINGLE_BARE_MODULE_METROLOGY)
MODULE/INIT
MODULE/ASSEMBLY
MODULE/WIREBONDING
MODULE/INITIAL_WARM
MODULE/QC_CROSSCHECK
MODULE/INITIAL_COLD
MODULE/PARYLENE_MASKING
MODULE/PARYLENE_COATING
MODULE/PARYLENE_UNMASKING
MODULE/WIREBOND_PROTECTION
MODULE/POST_PARYLENE_WARM
MODULE/POST_PARYLENE_COLD
MODULE/THERMAL_CYCLES
MODULE/LONG_TERM_STABILITY_TEST
MODULE/FINAL_WARM
MODULE/FINAL_COLD
MODULE/FINAL_METROLOGY
MODULE/QC_STATUS
MODULE/UNHAPPY
MODULE/NOTCONSIDEREDINYIELDS
MODULE/GRAVEYARD
MODULE/COMPLETE
MODULE/RECEPTION
MODULE/TAB_CUTTING
LLS/PRE_TC_WARM
LLS/PRE_TC_COLD
LLS/POST_TC_WARM
LLS/POST_TC_COLD
LLS/RECEPTION
OB_LOADED_MODULE_CELL/INIT
OB_LOADED_MODULE_CELL/ASSEMBLY
OB_LOADED_MODULE_CELL/THERMAL_CYCLES
OB_LOADED_MODULE_CELL/FINAL_WARM
OB_LOADED_MODULE_CELL/FINAL_COLD
OB_LOADED_MODULE_CELL/THERMAL_COLD
OB_LOADED_MODULE_CELL/THERMAL_WARM
OB_LOADED_MODULE_CELL/ENVELOPE_CHECK
OB_LOADED_MODULE_CELL/QC_STATUS
OB_LOADED_MODULE_CELL/UNHAPPY
OB_LOADED_MODULE_CELL/COMPLETE
OB_LOADED_MODULE_CELL/RECEPTION
OB_LOADED_MODULE_CELL/TAB_CUTTING
OB_LOADED_MODULE_CELL/PIGTAIL_INSERTION
Back to top page of this component