20UPIM13710377 (ANL_ITkPix_74)

MODULE/FINAL_METROLOGY

Component Information

Serial Number 20UPIM13710377
ProdDB ID  bd134c…bd607b
LocalDB ID 681b93a3d25f28d40e6a9e81
Component Type MODULE
Parents No match.
Children 20UPGB43000042 Bare Module 20UPGFC0156310 FE Chip 20UPGFC0156311 FE Chip 20UPGFC0156313 FE Chip 20UPGFC0156312 FE Chip 20UPGPQ3710377 PCB
Flags
Distribution of chips on wafer

 Properties

Item Value
FE chip version 3
PCB-Bare Orientation isNormal True
Alternative ID ANL_ITkPix_74
Is preproduction module True
Wirebond protection roof presence None
Rank None

 Comments


Test: GLUE_MODULE_FLEX_ATTACH QC Passed

(Stage: MODULE/ASSEMBLY)


Basic View Only: custom view for this TestRun is not prepared.

Metadata

Key Data
QC Passed True
Date 6 months ago
component ObjectId 681b93a3d25f28d40e6a9e81
Stage MODULE/ASSEMBLY
Test Type GLUE_MODULE_FLEX_ATTACH
Institute ObjectId
User Name DanielAceves
ObjectId of this record 68265bbeaf9c029c40bf8875
ObjectId of RAW record 68265bbdaf9c029c40bf8874
Tags No tags

Results

Key Data
BATCH_NUMBER SGP27814
CURE_TIME 24
GLUE_TYPE Epoxy
LOCATION_ASSEMBLY ANL
MEASUREMENT_DATE 2025-05-13T21:05:00.000+00:00
OPERATOR_IDENTITY Tim Cundiff
RATIO 1
TOOL_ID 33
TOOL_TYPE 1
HUMIDITY 40
TEMP 20

RAW Results Record

Download RAW
_id68265bbdaf9c029c40bf8874
raw
serialNumbertestTyperesultsstagecomponentdbVersionaddressusersys
20UPIM13710377GLUE_MODULE_FLEX_ATTACH
property
RATIO1.0
BATCH_NUMBERSGP27814
OPERATOR_IDENTITYTim Cundiff
GLUE_TYPEEpoxy
TOOL_TYPE1
TOOL_ID33
MEASUREMENT_DATENone
LOCATION_ASSEMBLYANL
CURE_TIME24.0
comment
Measurements
TEMP20.0
HUMIDITY40.0
Metadata
LocalDB version2.2.39-rc8
InstitutionANL
ModuleSN20UPIM13710377
TimeStart1747170300
TimeEnd1747256700
MODULE/ASSEMBLY681b93a3d25f28d40e6a9e811.0164657cef8d79bac1f3f00578admin
mts2025-05-15 21:25:17.565000
cts2025-05-15 21:25:17.565000
rev0
rawHashe53b08540258c80033b79d57eed6f714
stageMODULE/ASSEMBLY

ProductionDB Record

id685c658c2c9bdb0e7c8dcae7
stateready
stateTs2025-06-25T21:09:32.818Z
stateUserIdentity4728-7541-1
date2025-05-15T21:25:00.000Z
testType
id5d13188702c38f00090aaad9
codeGLUE_MODULE_FLEX_ATTACH
nameGlue Information Module+Flex Attach
stateactive
institution
id5d318624df98f200097386d5
codeANL
nameArgonne National Laboratory
user
id6526ef19d2e4250042313864
userIdentity4728-7541-1
firstNameDaniel
middleName
lastNameAceves
runNumber68265bbeaf9c029c40bf8875
passedTrue
problemsFalse
properties
  • codeBATCH_NUMBER
    nameGlue Batch Number
    dataTypestring
    valueTypesingle
    requiredTrue
    valueSGP27814
  • codeCURE_TIME
    nameCure time [h]
    dataTypefloat
    valueTypeNone
    requiredFalse
    value24
    rangeMinNone
    rangeMaxNone
  • codeGLUE_TYPE
    nameGlue type
    dataTypestring
    valueTypesingle
    requiredTrue
    valueEpoxy
  • codeLOCATION_ASSEMBLY
    nameLocation of assembly
    dataTypestring
    valueTypeNone
    requiredFalse
    valueANL
    rangeMinNone
    rangeMaxNone
  • codeMEASUREMENT_DATE
    nameDate of assembly
    dataTypedatetime
    valueTypeNone
    requiredFalse
    value2025-05-13T21:05:00.000+00:00
    rangeMinNone
    rangeMaxNone
  • codeOPERATOR_IDENTITY
    nameOperator identity
    dataTypestring
    valueTypesingle
    requiredFalse
    valueTim Cundiff
    rangeMinNone
    rangeMaxNone
  • codeRATIO
    nameRatio of epoxy mixture
    dataTypefloat
    valueTypesingle
    requiredFalse
    value1
  • codeTOOL_ID
    nameTool ID
    dataTypeinteger
    valueTypesingle
    requiredFalse
    value33
    rangeMinNone
    rangeMaxNone
  • codeTOOL_TYPE
    nameTool type
    dataTypecodeTable
    valueTypesingle
    requiredFalse
    value1
    codeTable
    codevalue
    1Common
    2Japan
    3Oxford
    4triplet
results
codenameorderdataTypevalueTypeadditionalrangeMinrangeMaxvalueassociateChild
HUMIDITYHumidity (%)1floatsingleFalseNoneNone40None
TEMPRoom Temperature (C)1floatsingleFalseNoneNone20None
cts2025-06-25T21:09:32.818Z
sys
cts2025-06-25T21:09:32.818Z
mts2025-06-25T21:09:33.251Z
rev1
defects
commentsNone
attachments
codedateTimetitledescriptioncontentTypetypebinaryStoreg02filenameuser
95948fe14b721ed0eb9884e3087f8a6a2025-06-25T21:09:33.038ZRAWRAWapplication/jsonfileTruedata
id6526ef19d2e4250042313864
userIdentity4728-7541-1
firstNameDaniel
middleName
lastNameAceves
components
idcodestatestateTsstateUserIdentitydummycompletedcompletedTscompletedUserIdentitytrashedtrashedTstrashedUserIdentityserialNumberalternativeIdentifierprojectsubprojectcomponentTypetypepropertiestestedAtStageinstitution
681b93a3d25f28d40e6a9e81bd134c33758c49cf5093f5d1d8bd607bready2025-05-07T17:08:51.975Z1294-8027-1FalseFalseNoneNoneFalseNoneNone20UPIM13710377ANL_ITkPix_74
codeP
namePixels
codePI
nameInner pixels
codeMODULE
nameModule
codeL1_QUAD_MODULE
nameL1 quad module
  • codeFECHIP_VERSION
    nameFE chip version
    dataTypecodeTable
    requiredTrue
    defaultFalse
    valueITkpix_v2
    codeTable
    codevalue
    0RD53A
    1ITkpix_v1
    2ITkpix_v1.1
    3ITkpix_v2
    9No FE chip
  • codeORIENTATION
    namePCB-Bare Orientation isNormal
    dataTypeboolean
    requiredTrue
    defaultFalse
    valueTrue
  • codeALTERNATIVE_IDENTIFIER
    nameAlternative ID
    dataTypestring
    requiredFalse
    defaultTrue
    valueANL_ITkPix_74
  • codeIS_PREPRODUCTION_MODULE
    nameIs preproduction module
    dataTypeboolean
    requiredFalse
    defaultFalse
    valueTrue
codeMODULE/ASSEMBLY
nameBare module to module PCB assembly
order1
initialFalse
finalFalse
codeANL
nameArgonne National Laboratory

 Current Stage: Final flatness measurement

Test Type Local Result
Flatness
(FLATNESS)
No TestRun!
Visual Inspection
(VISUAL_INSPECTION)
No TestRun!
IV measurement
(IV_MEASURE)
No TestRun!
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No TestRun!

 Candidate TestRuns of this Stage

LDB ID TestRun Code QC Passed Inspector Measurement Date Analysis Date Analysis Version Tags QC Registration
6876bf…ef17e4 QUAD_MODULE_METROLOGY Pass Simpson,Liana Rae N/A 5 months ago No tags Selected
68265d…bf8877 VISUAL_INSPECTION Pass DanielAceves 7 months ago 6 months ago 2.3.1rc3 No tags Selected
68265b…bf8875 GLUE_MODULE_FLEX_ATTACH Pass DanielAceves 7 months ago 6 months ago No tags Selected
68265b…bf8873 MASS_MEASUREMENT Pass DanielAceves 7 months ago 6 months ago 2.3.1rc3 No tags Selected

Past QC Stages and Results

Final Cold (MODULE/FINAL_COLD)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Final Warm (MODULE/FINAL_WARM)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Long Term Stability Test (MODULE/LONG_TERM_STABILITY_TEST)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Longterm stability DCS
(LONG_TERM_STABILITY_DCS)
No result N/A

Thermal Cycles (MODULE/THERMAL_CYCLES)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
Flatness
(FLATNESS)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Thermal Cycling
(THERMAL_CYCLING)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Post-Parylene Cold (MODULE/POST_PARYLENE_COLD)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Post-Parylene Warm (MODULE/POST_PARYLENE_WARM)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered

Wirebond Protection (alt) (MODULE/WIREBOND_PROTECTION)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Mass Measurement
(MASS_MEASUREMENT)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
No result N/A
Wire bonding protection roof envelope
(WP_ENVELOPE)
No result N/A

Parylene Unmasking (MODULE/PARYLENE_UNMASKING)

Test Local Result ProdDB Record
Parylene (de-)masking
(DE_MASKING)
Registered Registered
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
Flatness
(FLATNESS)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered

Parylene Coating (MODULE/PARYLENE_COATING)

Test Local Result ProdDB Record
Parylene Properties
(PARYLENE)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered

Parylene Masking (MODULE/PARYLENE_MASKING)

Test Local Result ProdDB Record
Parylene (de-)masking
(DE_MASKING)
Registered Registered
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered

Initial Cold (MODULE/INITIAL_COLD)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A

QC cross-check (module swapping) (MODULE/QC_CROSSCHECK)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered

Initial Warm (MODULE/INITIAL_WARM)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
No result N/A

Wire Bonding (MODULE/WIREBONDING)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered
Wirebond pull test
(WIREBOND_PULL_TEST)
Registered Registered
Wirebonding Information
(WIREBONDING)
Registered Registered

Bare module to module PCB assembly (MODULE/ASSEMBLY)

Test Local Result ProdDB Record
Flatness
(FLATNESS)
No result N/A
Glue Information Module+Flex Attach
(GLUE_MODULE_FLEX_ATTACH)
Registered Registered
Mass Measurement
(MASS_MEASUREMENT)
Registered Registered
Quad Module Metrology
(QUAD_MODULE_METROLOGY)
Registered Registered
Triplet Module Metrology
(TRIPLET_METROLOGY)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered

Initial state to associate flex to bare module (MODULE/INIT)

LocalDB Test ID Stage Test Name Inspector Measurement Date Analysis Date Tags QC Registration
688927…b5bb95 MODULE/FINAL_COLD IV_MEASURE GiordonStark 5 months ago 4 months ago No tags Selected
68a510…146c8a MODULE/FINAL_COLD E_SUMMARY GiordonStark N/A 4 months ago No tags Selected
6883b8…297f6c MODULE/FINAL_WARM IV_MEASURE GiordonStark 5 months ago 4 months ago No tags Selected
6887a9…b5babb MODULE/FINAL_WARM E_SUMMARY GiordonStark N/A 4 months ago No tags Selected
6883ae…297f24 MODULE/THERMAL_CYCLES THERMAL_CYCLING GiordonStark 5 months ago 4 months ago No tags Selected
687ff8…cf8c9d MODULE/POST_PARYLENE_WARM VISUAL_INSPECTION GiordonStark 5 months ago 4 months ago No tags Selected
687fc2…cf87f9 MODULE/POST_PARYLENE_WARM IV_MEASURE GiordonStark 5 months ago 4 months ago No tags Selected
687ff2…cf8c9a MODULE/POST_PARYLENE_WARM E_SUMMARY GiordonStark N/A 4 months ago No tags Selected
68767e…256a6a MODULE/PARYLENE_UNMASKING DE_MASKING GiordonStark 6 months ago 4 months ago No tags Selected
68767e…256a6c MODULE/PARYLENE_UNMASKING VISUAL_INSPECTION GiordonStark 5 months ago 4 months ago No tags Selected
68767d…256a65 MODULE/PARYLENE_COATING VISUAL_INSPECTION GiordonStark 5 months ago 4 months ago No tags Selected
68767b…256a62 MODULE/PARYLENE_COATING PARYLENE GiordonStark 6 months ago 4 months ago No tags Selected
68716f…25697d MODULE/PARYLENE_MASKING DE_MASKING GiordonStark 6 months ago 4 months ago No tags Selected
687179…2569a2 MODULE/PARYLENE_MASKING VISUAL_INSPECTION GiordonStark 5 months ago 4 months ago No tags Selected
68a36b…32fb83 MODULE/QC_CROSSCHECK E_SUMMARY DanielAceves N/A 4 months ago No tags Selected
68a367…32f71b MODULE/QC_CROSSCHECK IV_MEASURE DanielAceves 5 months ago 4 months ago No tags Selected
6841cf…f7cda0 MODULE/INITIAL_WARM E_SUMMARY DanielAceves N/A 4 months ago No tags Selected
6876c1…4d278f MODULE/WIREBONDING WIREBOND_PULL_TEST Simpson,Liana Rae N/A 5 months ago No tags Selected
6876bf…ef17e4 MODULE/ASSEMBLY QUAD_MODULE_METROLOGY Simpson,Liana Rae N/A 5 months ago No tags Selected
682e4c…85f925 MODULE/WIREBONDING VISUAL_INSPECTION DanielAceves 7 months ago 6 months ago No tags Selected
682e4c…85f921 MODULE/WIREBONDING WIREBONDING DanielAceves 7 months ago 6 months ago No tags Selected
68265d…bf8877 MODULE/ASSEMBLY VISUAL_INSPECTION DanielAceves 7 months ago 6 months ago No tags Selected
68265b…bf8875 MODULE/ASSEMBLY GLUE_MODULE_FLEX_ATTACH DanielAceves 7 months ago 6 months ago No tags Selected
68265b…bf8873 MODULE/ASSEMBLY MASS_MEASUREMENT DanielAceves 7 months ago 6 months ago No tags Selected
Stage Tests
MODULE/INIT
MODULE/ASSEMBLY
  • Mass Measurement  (MASS_MEASUREMENT)
  • Glue Information Module+Flex Attach  (GLUE_MODULE_FLEX_ATTACH)
  • Triplet Module Metrology  (TRIPLET_METROLOGY)
  • Visual Inspection  (VISUAL_INSPECTION)
  • Flatness  (FLATNESS)
  • Quad Module Metrology  (QUAD_MODULE_METROLOGY)
MODULE/WIREBONDING
  • Wirebonding Information  (WIREBONDING)
  • Wirebond pull test  (WIREBOND_PULL_TEST)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/INITIAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/QC_CROSSCHECK
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/INITIAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/PARYLENE_MASKING
  • Visual Inspection  (VISUAL_INSPECTION)
  • Parylene (de-)masking  (DE_MASKING)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/PARYLENE_COATING
  • Parylene Properties  (PARYLENE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/PARYLENE_UNMASKING
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Parylene (de-)masking  (DE_MASKING)
MODULE/WIREBOND_PROTECTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Wire bonding protection roof envelope  (WP_ENVELOPE)
  • Mass Measurement  (MASS_MEASUREMENT)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
MODULE/POST_PARYLENE_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/POST_PARYLENE_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/THERMAL_CYCLES
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Thermal Cycling  (THERMAL_CYCLING)
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
MODULE/LONG_TERM_STABILITY_TEST
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Longterm stability DCS  (LONG_TERM_STABILITY_DCS)
MODULE/FINAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/FINAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/FINAL_METROLOGY
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/QC_STATUS
  • Module ranking  (RANKING)
MODULE/UNHAPPY
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/NOTCONSIDEREDINYIELDS
MODULE/GRAVEYARD
MODULE/COMPLETE
MODULE/RECEPTION
  • Visual Inspection  (VISUAL_INSPECTION)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/TAB_CUTTING
  • Mass Measurement  (MASS_MEASUREMENT)
  • Module PCB Tab Cutting Information  (CUTTER_PCB_TAB)
  • Visual Inspection  (VISUAL_INSPECTION)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
LLS/PRE_TC_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/PRE_TC_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/POST_TC_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/POST_TC_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/RECEPTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
OB_LOADED_MODULE_CELL/INIT
OB_LOADED_MODULE_CELL/ASSEMBLY
OB_LOADED_MODULE_CELL/THERMAL_CYCLES
OB_LOADED_MODULE_CELL/FINAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/FINAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/THERMAL_COLD
  • Thermal Measure  (THERMAL_PERFORMANCE)
OB_LOADED_MODULE_CELL/THERMAL_WARM
  • Thermal Measure  (THERMAL_PERFORMANCE)
OB_LOADED_MODULE_CELL/ENVELOPE_CHECK
OB_LOADED_MODULE_CELL/QC_STATUS
OB_LOADED_MODULE_CELL/UNHAPPY
OB_LOADED_MODULE_CELL/COMPLETE
OB_LOADED_MODULE_CELL/RECEPTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/TAB_CUTTING
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Module PCB Tab Cutting Information  (CUTTER_PCB_TAB)
OB_LOADED_MODULE_CELL/PIGTAIL_INSERTION
Back to top page of this component