20UPIM13602053

MODULE/PARYLENE_MASKING

Component Information

Serial Number 20UPIM13602053
ProdDB ID  8ba02e…1db33c
LocalDB ID 67f66cae73b21e313576ff17
Component Type MODULE
Parents No match.
Children 20UPGB43000051 Bare Module 20UPGPQ3602053 PCB 20UPGFC0156298 FE Chip 20UPGFC0156299 FE Chip 20UPGFC0156301 FE Chip 20UPGFC0156300 FE Chip
Flags
Distribution of chips on wafer

 Properties

Item Value
PCB-Bare Orientation isNormal True
FE chip version 3
Wirebond protection roof presence False
Alternative ID None
Rank None

 Comments


Test: E_SUMMARY QC Failed

(Stage: MODULE/INITIAL_WARM)


Basic View Only: custom view for this TestRun is not prepared.

Metadata

Key Data
QC Passed False
Date 8 months ago
component ObjectId 67f66cae73b21e313576ff17
Stage MODULE/INITIAL_WARM
Test Type E_SUMMARY
Institute ObjectId
User Name AnnaRaquel Petri
ObjectId of this record 67ff6b0dcdcf6da2aa9c4a0c
ObjectId of RAW record None

Results

Key Data
ANALYSIS_VERSION localdb-tools v2.3.5
MEASUREMENT_DATE None
MODULE_TEMPERATURE 20
QUAD-MODULE_ADC_CALIBRATION 1 2 3 4
QUAD-MODULE_ANALOG_READBACK 1 2 3 4
MODULE_BAD_PIXEL_NUMBER 371
QUAD-MODULE_DATA_TRANSMISSION 1 2 3 4
MODULE_DISABLED_COLUMNS_NUMBER 0
MODULE_DISCONNECTED_PIXEL_NUMBER 308
MODULE_ELECTRICALLY_BAD_PIXEL_NUMBER 57
MODULE_HIGHEST_NUMBER_BAD_PIXELS_CLUSTER N/A
QUAD-MODULE_INJECTION_CAPACITANCE 1 2 3 4
QUAD-MODULE_LP_MODE 1 2 3 4
QUAD-MODULE_MIN_HEALTH_TEST 1 2 3 4
MODULE_OVERVOLTAGE_PROTECTION -1
MODULE_OVERVOLTAGE_PROTECTION_FE_LINK_1 N/A
MODULE_OVERVOLTAGE_PROTECTION_FE_LINK_2 N/A
MODULE_OVERVOLTAGE_PROTECTION_FE_LINK_3 N/A
MODULE_OVERVOLTAGE_PROTECTION_FE_LINK_4 N/A
QUAD-MODULE_PIXEL_FAILURE_ANALYSIS 1 2 3 4
QUAD-MODULE_SLDO 1 2 3 4
QUAD-MODULE_TUNING 1 2 3 4
MODULE_UNDERSHUNT_PROTECTION -1
MODULE_UNDERSHUNT_PROTECTION_FE_LINK_1 N/A
MODULE_UNDERSHUNT_PROTECTION_FE_LINK_2 N/A
MODULE_UNDERSHUNT_PROTECTION_FE_LINK_3 N/A
MODULE_UNDERSHUNT_PROTECTION_FE_LINK_4 N/A
QUAD-MODULE_VCAL_CALIBRATION 1 2 3 4

Key Data
BAD_PIXEL_NUMBER 71
DISABLED_COLUMNS_NUMBER 0
DISCONNECTED_PIXEL_NUMBER 64
ELECTRICALLY_BAD_PIXEL_NUMBER 7
HIGHEST_NUMBER_BAD_PIXELS_CLUSTER N/A
Key Data
BAD_PIXEL_NUMBER 93
DISABLED_COLUMNS_NUMBER 0
DISCONNECTED_PIXEL_NUMBER 90
ELECTRICALLY_BAD_PIXEL_NUMBER 3
HIGHEST_NUMBER_BAD_PIXELS_CLUSTER N/A
Key Data
BAD_PIXEL_NUMBER 62
DISABLED_COLUMNS_NUMBER 0
DISCONNECTED_PIXEL_NUMBER 61
ELECTRICALLY_BAD_PIXEL_NUMBER 1
HIGHEST_NUMBER_BAD_PIXELS_CLUSTER N/A
Key Data
BAD_PIXEL_NUMBER 145
DISABLED_COLUMNS_NUMBER 0
DISCONNECTED_PIXEL_NUMBER 93
ELECTRICALLY_BAD_PIXEL_NUMBER 46
HIGHEST_NUMBER_BAD_PIXELS_CLUSTER N/A

ProductionDB Record

{}

 Current Stage: Parylene Masking

Test Type Local Result
Visual Inspection
(VISUAL_INSPECTION)
No TestRun!
Parylene (de-)masking
(DE_MASKING)
No TestRun!

 Candidate TestRuns of this Stage

LDB ID TestRun Code QC Passed Inspector Measurement Date Analysis Date Analysis Version Tags QC Registration
67fe82…9c4540 IV_MEASURE Fail AnnaRaquel Petri 8 months ago 8 months ago 2.4.1 No tags Selected
67ff6b…9c4a0c E_SUMMARY Fail AnnaRaquel Petri N/A 8 months ago 2.3.5 No tags Selected

Past QC Stages and Results

Initial Cold (MODULE/INITIAL_COLD)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A

QC cross-check (module swapping) (MODULE/QC_CROSSCHECK)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A

Initial Warm (MODULE/INITIAL_WARM)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered

Wire Bonding (MODULE/WIREBONDING)

Test Local Result ProdDB Record
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered
Wirebond pull test
(WIREBOND_PULL_TEST)
Registered Registered
Wirebonding Information
(WIREBONDING)
No result N/A

Bare module to module PCB assembly (MODULE/ASSEMBLY)

Test Local Result ProdDB Record
Flatness
(FLATNESS)
No result N/A
Glue Information Module+Flex Attach
(GLUE_MODULE_FLEX_ATTACH)
Registered Registered
Mass Measurement
(MASS_MEASUREMENT)
Registered Registered
Quad Module Metrology
(QUAD_MODULE_METROLOGY)
Registered Registered
Triplet Module Metrology
(TRIPLET_METROLOGY)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered

Initial state to associate flex to bare module (MODULE/INIT)

LocalDB Test ID Stage Test Name Inspector Measurement Date Analysis Date Tags QC Registration
67fe82…9c4540 MODULE/INITIAL_WARM IV_MEASURE AnnaRaquel Petri 8 months ago 8 months ago No tags Selected
67ff6b…9c4a0c MODULE/INITIAL_WARM E_SUMMARY AnnaRaquel Petri N/A 8 months ago No tags Selected
680a0f…9d9345 MODULE/WIREBONDING WIREBOND_PULL_TEST AnnaRaquel Petri N/A 8 months ago No tags Selected
680a08…77debe MODULE/ASSEMBLY QUAD_MODULE_METROLOGY AnnaRaquel Petri N/A 8 months ago No tags Selected
680a0a…9c5d27 MODULE/ASSEMBLY GLUE_MODULE_FLEX_ATTACH AnnaRaquel Petri 8 months ago 8 months ago No tags Selected
680a0b…9c5d2a MODULE/ASSEMBLY MASS_MEASUREMENT AnnaRaquel Petri 8 months ago 8 months ago No tags Selected
Stage Tests
MODULE/INIT
MODULE/ASSEMBLY
  • Mass Measurement  (MASS_MEASUREMENT)
  • Glue Information Module+Flex Attach  (GLUE_MODULE_FLEX_ATTACH)
  • Triplet Module Metrology  (TRIPLET_METROLOGY)
  • Visual Inspection  (VISUAL_INSPECTION)
  • Flatness  (FLATNESS)
  • Quad Module Metrology  (QUAD_MODULE_METROLOGY)
MODULE/WIREBONDING
  • Wirebonding Information  (WIREBONDING)
  • Wirebond pull test  (WIREBOND_PULL_TEST)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/INITIAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/QC_CROSSCHECK
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/INITIAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/PARYLENE_MASKING
  • Visual Inspection  (VISUAL_INSPECTION)
  • Parylene (de-)masking  (DE_MASKING)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/PARYLENE_COATING
  • Parylene Properties  (PARYLENE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/PARYLENE_UNMASKING
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Parylene (de-)masking  (DE_MASKING)
MODULE/WIREBOND_PROTECTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Wire bonding protection roof envelope  (WP_ENVELOPE)
  • Mass Measurement  (MASS_MEASUREMENT)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
MODULE/POST_PARYLENE_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/POST_PARYLENE_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/THERMAL_CYCLES
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Thermal Cycling  (THERMAL_CYCLING)
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
MODULE/LONG_TERM_STABILITY_TEST
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Longterm stability DCS  (LONG_TERM_STABILITY_DCS)
MODULE/FINAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/FINAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/FINAL_METROLOGY
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/QC_STATUS
  • Module ranking  (RANKING)
MODULE/UNHAPPY
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/NOTCONSIDEREDINYIELDS
MODULE/GRAVEYARD
MODULE/COMPLETE
MODULE/RECEPTION
  • Visual Inspection  (VISUAL_INSPECTION)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/TAB_CUTTING
  • Mass Measurement  (MASS_MEASUREMENT)
  • Module PCB Tab Cutting Information  (CUTTER_PCB_TAB)
  • Visual Inspection  (VISUAL_INSPECTION)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
LLS/PRE_TC_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/PRE_TC_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/POST_TC_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/POST_TC_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/RECEPTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
OB_LOADED_MODULE_CELL/INIT
OB_LOADED_MODULE_CELL/ASSEMBLY
OB_LOADED_MODULE_CELL/THERMAL_CYCLES
OB_LOADED_MODULE_CELL/FINAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/FINAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/THERMAL_COLD
  • Thermal Measure  (THERMAL_PERFORMANCE)
OB_LOADED_MODULE_CELL/THERMAL_WARM
  • Thermal Measure  (THERMAL_PERFORMANCE)
OB_LOADED_MODULE_CELL/ENVELOPE_CHECK
OB_LOADED_MODULE_CELL/QC_STATUS
OB_LOADED_MODULE_CELL/UNHAPPY
OB_LOADED_MODULE_CELL/COMPLETE
OB_LOADED_MODULE_CELL/RECEPTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/TAB_CUTTING
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Module PCB Tab Cutting Information  (CUTTER_PCB_TAB)
OB_LOADED_MODULE_CELL/PIGTAIL_INSERTION
Back to top page of this component