20UPGM23211199

MODULE/INITIAL_COLD

Component Information

Serial Number 20UPGM23211199
ProdDB ID  91d91d…90899b
LocalDB ID 677eab4f9840dd877b1a133a
Component Type MODULE
Parents No match.
Children 20UPGB43200080 Bare Module 20UPGPQ2211199 PCB 20UPGFC0133685 FE Chip 20UPGFC0133782 FE Chip 20UPGFC0133802 FE Chip 20UPGFC0133752 FE Chip
Flags
Distribution of chips on wafer

 Properties

Item Value
FE chip version 3
PCB-Bare Orientation isNormal True
Wirebond protection roof presence None
Alternative ID None
Rank None

 Comments


Test: IV_MEASURE QC Passed

(Stage: MODULE/INITIAL_WARM)


Basic View Only: custom view for this TestRun is not prepared.

Metadata

Key Data
QC Passed True
Date 11 months ago
component ObjectId 677eab4f9840dd877b1a133a
Stage MODULE/INITIAL_WARM
Test Type IV_MEASURE
Institute ObjectId
User Name SimoneRavera
ObjectId of this record 679142d8d6d45f614eece466
ObjectId of RAW record 679142d5d6d45f614eece45f
Tags No tags

Results

Key Data
ANALYSIS_VERSION mqat v2.3.0
HUM 0
MEASUREMENT_DATE 2025-01-22T18:54:44.000+00:00
MEASUREMENT_DURATION None
TEMP 19.62
BREAKDOWN_REDUCTION 0
BREAKDOWN_VOLTAGE -999
IV_ARRAY {'time': [13.864752769470215, 51.62775421142578, 89.02068758010864, 124.89773082733154, 160.47800850868225, 196.91151404380798, 232.89164185523987, 271.0053949356079, 308.98637437820435, 346.50142455101013, 383.42892479896545, 420.530633687973, 458.6182143688202, 494.34635734558105, 530.474360704422, 567.1049172878265, 603.6154816150665, 642.4079179763794, 680.3609864711761, 719.0164482593536, 754.4651370048523], 'voltage': [0.08621002733707428, 10.058389663696289, 20.059919357299805, 30.059099197387695, 40.054649353027344, 50.07162857055664, 60.068939208984375, 70.06865692138672, 80.06568145751953, 90.06575775146484, 100.07730102539062, 110.07219696044922, 120.07060241699219, 130.06849670410156, 140.0625, 150.0778045654297, 160.07940673828125, 170.07569885253906, 180.07000732421875, 190.0675048828125, 200.0847930908203], 'current': [0.05432657227781116, 0.5013550700520378, 0.5616656532462608, 0.5971143082206254, 0.6184105245665705, 0.6290068957544767, 0.6404616025671809, 0.6450376114723136, 0.6517070877028649, 0.6533128953378764, 0.6558331241042955, 0.660328093241939, 0.6613062547936958, 0.664934096524424, 0.6697839580738219, 0.6772160645596159, 0.6774958668150551, 0.6844436105287363, 0.6854491895561902, 0.6895373113972406, 0.6955700276497131], 'sigma current': [0.0015092004633784216, 0.0034451518921078425, 0.004767792108225258, 0.00013191128247605943, 0.0021860815671576987, 0.002773156914030823, 0.004720039135639657, 0.00407174844115993, 0.0018688348182902955, 0.0053742658032562216, 0.0015125853966062746, 0.0008724904703868715, 0.0021023696189278337, 0.0009919908962941963, 0.0027542090820755556, 0.002792891750259553, 0.001970040304200252, 0.004151913773809843, 0.0016256555934728116, 0.0017452466741017135, 0.0051976720274077085], 'temperature': [19.765710830688477, 19.74895668029785, 19.71360206604004, 19.69651222229004, 19.690576553344727, 19.656885147094727, 19.65532875061035, 19.630273818969727, 19.70415687561035, 19.5560245513916, 19.58599281311035, 19.552515029907227, 19.60910987854004, 19.57450294494629, 19.554895401000977, 19.5302677154541, 19.55930519104004, 19.58526039123535, 19.542200088500977, 19.547677993774414, 19.4675235748291], 'humidity': []}
LEAK_CURRENT 0.6853161523449013
LEAK_INCREASE_FACTOR 0.88
LEAK_PER_AREA 0.04
MAXIMUM_VOLTAGE 200.0847930908203
NO_BREAKDOWN_VOLTAGE_OBSERVED True

Attachments

Filename Contents
output.log Download
20UPGM23211199_plot.png
20UPGM23211199_summary.png

RAW Results Record

Download RAW
_id679142d5d6d45f614eece45f
raw
serialNumbertestTypesubtestTyperesultsstagecomponentdbVersionaddresssys
20UPGM23211199IV_MEASURE
property
IV_MEASURE_MEASUREMENT_VERSION2.3.0
comment
Measurements
time
XFalse
Units
Values
  • 13.864752769470215
  • 51.62775421142578
  • 89.02068758010864
  • 124.89773082733154
  • 160.47800850868225
  • 196.91151404380798
  • 232.89164185523987
  • 271.0053949356079
  • 308.98637437820435
  • 346.50142455101013
  • 383.42892479896545
  • 420.530633687973
  • 458.6182143688202
  • 494.34635734558105
  • 530.474360704422
  • 567.1049172878265
  • 603.6154816150665
  • 642.4079179763794
  • 680.3609864711761
  • 719.0164482593536
  • 754.4651370048523
voltage
XTrue
UnitV
Values
  • -0.08621002733707428
  • -10.058389663696289
  • -20.059919357299805
  • -30.059099197387695
  • -40.054649353027344
  • -50.07162857055664
  • -60.068939208984375
  • -70.06865692138672
  • -80.06568145751953
  • -90.06575775146484
  • -100.07730102539062
  • -110.07219696044922
  • -120.07060241699219
  • -130.06849670410156
  • -140.0625
  • -150.0778045654297
  • -160.07940673828125
  • -170.07569885253906
  • -180.07000732421875
  • -190.0675048828125
  • -200.0847930908203
current
XFalse
UnitA
Values
  • 5.432657227781116e-08
  • -5.013550700520378e-07
  • -5.616656532462608e-07
  • -5.971143082206254e-07
  • -6.184105245665705e-07
  • -6.290068957544767e-07
  • -6.404616025671809e-07
  • -6.450376114723136e-07
  • -6.517070877028649e-07
  • -6.533128953378764e-07
  • -6.558331241042955e-07
  • -6.60328093241939e-07
  • -6.613062547936958e-07
  • -6.64934096524424e-07
  • -6.697839580738219e-07
  • -6.772160645596159e-07
  • -6.774958668150551e-07
  • -6.844436105287363e-07
  • -6.854491895561902e-07
  • -6.895373113972406e-07
  • -6.955700276497131e-07
sigma current
XFalse
UnitA
Values
  • 1.5092004633784216e-09
  • 3.4451518921078425e-09
  • 4.767792108225257e-09
  • 1.3191128247605942e-10
  • 2.1860815671576988e-09
  • 2.7731569140308226e-09
  • 4.720039135639657e-09
  • 4.07174844115993e-09
  • 1.8688348182902954e-09
  • 5.3742658032562215e-09
  • 1.5125853966062746e-09
  • 8.724904703868714e-10
  • 2.1023696189278337e-09
  • 9.919908962941962e-10
  • 2.7542090820755556e-09
  • 2.7928917502595527e-09
  • 1.970040304200252e-09
  • 4.1519137738098426e-09
  • 1.6256555934728115e-09
  • 1.7452466741017134e-09
  • 5.197672027407708e-09
temperature
XFalse
UnitC
Values
  • 19.765710830688477
  • 19.74895668029785
  • 19.71360206604004
  • 19.69651222229004
  • 19.690576553344727
  • 19.656885147094727
  • 19.65532875061035
  • 19.630273818969727
  • 19.70415687561035
  • 19.5560245513916
  • 19.58599281311035
  • 19.552515029907227
  • 19.60910987854004
  • 19.57450294494629
  • 19.554895401000977
  • 19.5302677154541
  • 19.55930519104004
  • 19.58526039123535
  • 19.542200088500977
  • 19.547677993774414
  • 19.4675235748291
humidity
XFalse
Unit%
Values
Metadata
AverageTemperature19.61558469136556
SettlingTime1
TimeStart1737572084
TimeEnd1737573072
InstitutionINFN-GENOVA
ModuleSN20UPGM23211199
DepletionVoltageNone
MODULE/INITIAL_WARM677eab4f9840dd877b1a133a1.0164657cef8d79bac1f3f00580
mts2025-01-22 19:11:17.416000
cts2025-01-22 19:11:17.416000
rev0
rawHash2ca36bba51def073d7a41c34ad4020d3
stageMODULE/INITIAL_WARM

ProductionDB Record

id679173de9ad8e83538383adc
stateready
stateTs2025-01-22T22:40:30.863Z
stateUserIdentity7608-2618-1
date2025-01-22T19:11:00.000Z
testType
id6418494b21d98a00388285bd
codeIV_MEASURE
nameIV measurement
stateactive
institution
id5d41d52cf6e07b000a559ada
codeINFN_GENOA
nameINFN Genoa
user
id637374d78324460028c3e967
userIdentity7608-2618-1
firstNameSimone
middleName
lastNameRavera
runNumber679142d8d6d45f614eece466
passedTrue
problemsFalse
properties
codenamedataTypevalueTyperequiredvaluerangeMinrangeMax
ANALYSIS_VERSIONAnalysis VersionstringsingleFalse2.3.0NoneNone
HUMHumidity (%)floatsingleTrue0NoneNone
MEASUREMENT_DATEDate measurement performeddatetimeNoneFalse2025-01-22T18:54:44.000+00:00NoneNone
MEASUREMENT_DURATIONMeasurement durationintegerNoneFalseNoneNoneNone
TEMPTemperature (°C)floatsingleTrue19.62NoneNone
results
codenamedataTypevalueTypearrayDimensionsadditionalrangeMinrangeMaxvalueassociateChild
BREAKDOWN_REDUCTIONBreakdown Voltage Reduction (V)floatsingleNoneFalseNoneNone0None
BREAKDOWN_VOLTAGEBreakdown voltage (V) (-999V if no breakdown measured)floatsingleNoneFalseNoneNone-999None
IV_ARRAYIV dataobjectsingleNoneFalseNoneNone
time
  • 13.864752769470215
  • 51.62775421142578
  • 89.02068758010864
  • 124.89773082733154
  • 160.47800850868225
  • 196.91151404380798
  • 232.89164185523987
  • 271.0053949356079
  • 308.98637437820435
  • 346.50142455101013
  • 383.42892479896545
  • 420.530633687973
  • 458.6182143688202
  • 494.34635734558105
  • 530.474360704422
  • 567.1049172878265
  • 603.6154816150665
  • 642.4079179763794
  • 680.3609864711761
  • 719.0164482593536
  • 754.4651370048523
voltage
  • 0.08621002733707428
  • 10.058389663696289
  • 20.059919357299805
  • 30.059099197387695
  • 40.054649353027344
  • 50.07162857055664
  • 60.068939208984375
  • 70.06865692138672
  • 80.06568145751953
  • 90.06575775146484
  • 100.07730102539062
  • 110.07219696044922
  • 120.07060241699219
  • 130.06849670410156
  • 140.0625
  • 150.0778045654297
  • 160.07940673828125
  • 170.07569885253906
  • 180.07000732421875
  • 190.0675048828125
  • 200.0847930908203
current
  • 0.05432657227781116
  • 0.5013550700520378
  • 0.5616656532462608
  • 0.5971143082206254
  • 0.6184105245665705
  • 0.6290068957544767
  • 0.6404616025671809
  • 0.6450376114723136
  • 0.6517070877028649
  • 0.6533128953378764
  • 0.6558331241042955
  • 0.660328093241939
  • 0.6613062547936958
  • 0.664934096524424
  • 0.6697839580738219
  • 0.6772160645596159
  • 0.6774958668150551
  • 0.6844436105287363
  • 0.6854491895561902
  • 0.6895373113972406
  • 0.6955700276497131
sigma current
  • 0.0015092004633784216
  • 0.0034451518921078425
  • 0.004767792108225258
  • 0.00013191128247605943
  • 0.0021860815671576987
  • 0.002773156914030823
  • 0.004720039135639657
  • 0.00407174844115993
  • 0.0018688348182902955
  • 0.0053742658032562216
  • 0.0015125853966062746
  • 0.0008724904703868715
  • 0.0021023696189278337
  • 0.0009919908962941963
  • 0.0027542090820755556
  • 0.002792891750259553
  • 0.001970040304200252
  • 0.004151913773809843
  • 0.0016256555934728116
  • 0.0017452466741017135
  • 0.0051976720274077085
temperature
  • 19.765710830688477
  • 19.74895668029785
  • 19.71360206604004
  • 19.69651222229004
  • 19.690576553344727
  • 19.656885147094727
  • 19.65532875061035
  • 19.630273818969727
  • 19.70415687561035
  • 19.5560245513916
  • 19.58599281311035
  • 19.552515029907227
  • 19.60910987854004
  • 19.57450294494629
  • 19.554895401000977
  • 19.5302677154541
  • 19.55930519104004
  • 19.58526039123535
  • 19.542200088500977
  • 19.547677993774414
  • 19.4675235748291
humidity
None
LEAK_CURRENTLeakage current of sensor (μA) at operation voltagefloatsingleNoneFalseNoneNone0.6853161523449013None
LEAK_INCREASE_FACTORLeakage Current Increase FactorfloatsingleNoneFalseNoneNone0.88None
LEAK_PER_AREALeakage Current per Area (uA/cm^2)floatsingleNoneFalseNoneNone0.04None
MAXIMUM_VOLTAGEMaximum (absolute) measured voltage (V)floatsingleNoneFalseNoneNone200.0847930908203None
NO_BREAKDOWN_VOLTAGE_OBSERVEDNo breakdown voltage observedbooleansingleNoneFalseNoneNoneTrueNone
cts2025-01-22T22:40:30.863Z
sys
cts2025-01-22T22:40:30.863Z
mts2025-01-22T22:40:32.316Z
rev2
defects
commentsNone
attachments
  • code5636a7c3ca3c4f415e5cde2c20909dbd
    dateTime2025-01-22T22:40:31.209Z
    titleTestRun_679173de9ad8e83538383adc_Attachment_Pack.zip
    description/opt/localdb-viewer/viewer-2.2.37/static/cache/thumbnail/TestRun_679173de9ad8e83538383adc_Attachment_Pack.zip
    contentTypeNone
    typeeos
    urlhttps://eosatlas.cern.ch/eos/atlas/atlascerngroupdisk/det-itk/prod-db/5/6/3/5636a7c3ca3c4f415e5cde2c20909dbd?authz=zteos64:MDAwMDAyOWN4nO2QP0vDUBTFacGKncSx00UFdcifm5e_F0E3oaO4SMiQ-F7a2DYvJC-DBT-AH8DZRTd3F9FBEB3EL9HVSXFxsRYHBydn73C4_Dj3cjjtq2a7US6-PzxetzpzmRoUfLk5LtYbFjOErIxYDeNvPRBl3itlXfCsGhhcKG1qN4pSco0nhmO4BuuuCjuxGApT40GQaogi1XzmuVpsJ6mJXuB6VrB71wj3-jV04xwsBugS88hkYJmWE0GdcUIbXR_DWZwIel-EmV44LiJQGRe5olJKpaOLjs2Q7ID52yFROh1yUEd09cDX0Ywgj0eCZn-A5wTTtIoGZeJAXBQEfVkp-v2Qy1Gc5fSD9IQk00EGVc2n2xJcigvx9DbZWhge3p5x72j--Hk_2Hz9mJysvPCNnbXOf7d_7BbO729OW5_Kt86R
    urlCernboxhttps://cernbox.cern.ch/files/spaces/eos/atlas/atlascerngroupdisk/det-itk/prod-db/5/6/3/5636a7c3ca3c4f415e5cde2c20909dbd
    filename5636a7c3ca3c4f415e5cde2c20909dbd
    user
    id637374d78324460028c3e967
    userIdentity7608-2618-1
    firstNameSimone
    middleName
    lastNameRavera
  • code6315cb1571cc1835e5eff14ae1b0b296
    dateTime2025-01-22T22:40:32.216Z
    titleRAW
    descriptionRAW
    contentTypetext/plain
    typefile
    binaryStoreg02True
    filename20UPGM23211199_MODULE__INITIAL_WARM_IV_MEASURE_679173de9ad8e83538383adc_679142d5d6d45f614eece45f.json
    user
    id637374d78324460028c3e967
    userIdentity7608-2618-1
    firstNameSimone
    middleName
    lastNameRavera
components
idcodestatestateTsstateUserIdentitydummycompletedcompletedTscompletedUserIdentitytrashedtrashedTstrashedUserIdentityserialNumberalternativeIdentifierprojectsubprojectcomponentTypetypepropertiestestedAtStageinstitution
677eab4f9840dd877b1a133a91d91d02967b4ea2a530b8b50690899bready2025-01-08T16:43:59.335Z7608-2618-1FalseFalseNoneNoneFalseNoneNone20UPGM23211199None
codeP
namePixels
codePG
namePixel general
codeMODULE
nameModule
codeOUTER_SYSTEM_QUAD_MODULE
nameOuter system quad module
  • codeFECHIP_VERSION
    nameFE chip version
    dataTypecodeTable
    requiredTrue
    defaultFalse
    valueITkpix_v2
    codeTable
    codevalue
    0RD53A
    1ITkpix_v1
    2ITkpix_v1.1
    3ITkpix_v2
    9No FE chip
  • codeORIENTATION
    namePCB-Bare Orientation isNormal
    dataTypeboolean
    requiredTrue
    defaultFalse
    valueTrue
codeMODULE/INITIAL_WARM
nameInitial Warm
order3
initialFalse
finalFalse
codeINFN_GENOA
nameINFN Genoa

 Current Stage: Initial Cold

Test Type Local Result
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No TestRun!
IV measurement
(IV_MEASURE)
No TestRun!

 Candidate TestRuns of this Stage

LDB ID TestRun Code QC Passed Inspector Measurement Date Analysis Date Analysis Version Tags QC Registration
680ff5…80ec0a E_SUMMARY Fail SimoneRavera N/A 8 months ago 2.3.0 No tags
679142…ece466 IV_MEASURE Pass SimoneRavera 11 months ago 11 months ago 2.3.0 No tags Selected
679172…ece8f7 E_SUMMARY Fail SimoneRavera N/A 11 months ago 2.2.37 No tags Selected

Past QC Stages and Results

QC cross-check (module swapping) (MODULE/QC_CROSSCHECK)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A

Initial Warm (MODULE/INITIAL_WARM)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered

Wire Bonding (MODULE/WIREBONDING)

Test Local Result ProdDB Record
Visual Inspection
(VISUAL_INSPECTION)
No result N/A
Wirebond pull test
(WIREBOND_PULL_TEST)
No result N/A
Wirebonding Information
(WIREBONDING)
No result N/A

Bare module to module PCB assembly (MODULE/ASSEMBLY)

Test Local Result ProdDB Record
Flatness
(FLATNESS)
No result N/A
Glue Information Module+Flex Attach
(GLUE_MODULE_FLEX_ATTACH)
No result N/A
Mass Measurement
(MASS_MEASUREMENT)
No result N/A
Quad Module Metrology
(QUAD_MODULE_METROLOGY)
No result N/A
Triplet Module Metrology
(TRIPLET_METROLOGY)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Initial state to associate flex to bare module (MODULE/INIT)

LocalDB Test ID Stage Test Name Inspector Measurement Date Analysis Date Tags QC Registration
680ff5…80ec0a MODULE/INITIAL_WARM E_SUMMARY SimoneRavera N/A 8 months ago No tags
679142…ece466 MODULE/INITIAL_WARM IV_MEASURE SimoneRavera 11 months ago 11 months ago No tags Selected
679172…ece8f7 MODULE/INITIAL_WARM E_SUMMARY SimoneRavera N/A 11 months ago No tags Selected
Stage Tests
MODULE/INIT
MODULE/ASSEMBLY
  • Mass Measurement  (MASS_MEASUREMENT)
  • Glue Information Module+Flex Attach  (GLUE_MODULE_FLEX_ATTACH)
  • Triplet Module Metrology  (TRIPLET_METROLOGY)
  • Visual Inspection  (VISUAL_INSPECTION)
  • Flatness  (FLATNESS)
  • Quad Module Metrology  (QUAD_MODULE_METROLOGY)
MODULE/WIREBONDING
  • Wirebonding Information  (WIREBONDING)
  • Wirebond pull test  (WIREBOND_PULL_TEST)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/INITIAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/QC_CROSSCHECK
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/INITIAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/PARYLENE_MASKING
  • Visual Inspection  (VISUAL_INSPECTION)
  • Parylene (de-)masking  (DE_MASKING)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/PARYLENE_COATING
  • Parylene Properties  (PARYLENE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/PARYLENE_UNMASKING
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Parylene (de-)masking  (DE_MASKING)
MODULE/WIREBOND_PROTECTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Wire bonding protection roof envelope  (WP_ENVELOPE)
  • Mass Measurement  (MASS_MEASUREMENT)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
MODULE/POST_PARYLENE_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/POST_PARYLENE_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/THERMAL_CYCLES
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Thermal Cycling  (THERMAL_CYCLING)
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
MODULE/LONG_TERM_STABILITY_TEST
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Longterm stability DCS  (LONG_TERM_STABILITY_DCS)
MODULE/FINAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/FINAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/FINAL_METROLOGY
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/QC_STATUS
  • Module ranking  (RANKING)
MODULE/UNHAPPY
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/NOTCONSIDEREDINYIELDS
MODULE/GRAVEYARD
MODULE/COMPLETE
MODULE/RECEPTION
  • Visual Inspection  (VISUAL_INSPECTION)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/TAB_CUTTING
  • Mass Measurement  (MASS_MEASUREMENT)
  • Module PCB Tab Cutting Information  (CUTTER_PCB_TAB)
  • Visual Inspection  (VISUAL_INSPECTION)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
LLS/PRE_TC_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/PRE_TC_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/POST_TC_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/POST_TC_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/RECEPTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
OB_LOADED_MODULE_CELL/INIT
OB_LOADED_MODULE_CELL/ASSEMBLY
OB_LOADED_MODULE_CELL/THERMAL_CYCLES
OB_LOADED_MODULE_CELL/FINAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/FINAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/THERMAL_COLD
  • Thermal Measure  (THERMAL_PERFORMANCE)
OB_LOADED_MODULE_CELL/THERMAL_WARM
  • Thermal Measure  (THERMAL_PERFORMANCE)
OB_LOADED_MODULE_CELL/ENVELOPE_CHECK
OB_LOADED_MODULE_CELL/QC_STATUS
OB_LOADED_MODULE_CELL/UNHAPPY
OB_LOADED_MODULE_CELL/COMPLETE
OB_LOADED_MODULE_CELL/RECEPTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/TAB_CUTTING
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Module PCB Tab Cutting Information  (CUTTER_PCB_TAB)
OB_LOADED_MODULE_CELL/PIGTAIL_INSERTION