20UPGM23211208

MODULE/TAB_CUTTING

Component Information

Serial Number 20UPGM23211208
ProdDB ID  d84b34…9f0438
LocalDB ID 67506ad04457d9315d982a1e
Component Type MODULE
Parents No match.
Children 20UPGB43200031 Bare Module 20UPGPQ2211208 PCB 20UPGFC0133432 FE Chip 20UPGFC0133417 FE Chip 20UPGFC0133515 FE Chip 20UPGFC0133466 FE Chip
Flags
Distribution of chips on wafer

 Properties

Item Value
FE chip version 3
PCB-Bare Orientation isNormal True
Is preproduction module True
Wirebond protection roof presence None
Alternative ID None
Rank None

 Comments


Test: QUAD_MODULE_METROLOGY QC Failed

(Stage: MODULE/ASSEMBLY)


Basic View Only: custom view for this TestRun is not prepared.

Metadata

Key Data
QC Passed False
Date a year ago
component ObjectId 67506ad04457d9315d982a1e
Stage MODULE/ASSEMBLY
Test Type QUAD_MODULE_METROLOGY
Institute ObjectId
User Name AnnaRaquel Petri
ObjectId of this record 675c4a1c6496fd408f976112
ObjectId of RAW record 675c4a1b6496fd408f976111
Tags No tags

Results

Key Data
ANALYSIS_VERSION mqat v2.2.9
MEASUREMENT_DATE 2024-12-13T14:48:36.000+00:00
OPERATOR_IDENTITY None
AVERAGE_THICKNESS [662, 669, 651, 624]
DISTANCE_PCB_BARE_MODULE_BOTTOM_RIGHT [2.184, 0.905]
DISTANCE_PCB_BARE_MODULE_TOP_LEFT [2.201, 0.68]
FIDUCIAL True
HV_CAPACITOR_THICKNESS 2380
STD_DEVIATION_THICKNESS [0, 0, 0, 0]
THICKNESS_INCLUDING_POWER_CONNECTOR 1995
THICKNESS_VARIATION_PICKUP_AREA 45

RAW Results Record

Download RAW
_id675c4a1b6496fd408f976111
raw
serialNumbertestTypesubtestTyperesultsstagecomponentdbVersionaddresssys
20UPGM23211208QUAD_MODULE_METROLOGY
property
ANALYSIS_VERSIONNone
MEASUREMENT_DATENone
OPERATOR_IDENTITYNone
QUAD_MODULE_METROLOGY_MEASUREMENT_VERSION0.1.0
comment
Metadata
QCHELPER_VERSION0.1.0
ModuleSN20UPGM23211208
TimeStart1734101316
Measurements
DISTANCE_PCB_BARE_MODULE_TOP_LEFT
  • 2.201
  • 0.68
DISTANCE_PCB_BARE_MODULE_BOTTOM_RIGHT
  • 2.184
  • 0.905
ANGLE_PCB_BM0.0
AVERAGE_THICKNESS
  • 0.662
  • 0.669
  • 0.651
  • 0.624
STD_DEVIATION_THICKNESS
  • 0.0
  • 0.0
  • 0.0
  • 0.0
THICKNESS_VARIATION_PICKUP_AREA0.045
THICKNESS_INCLUDING_POWER_CONNECTOR1.995
HV_CAPACITOR_THICKNESS2.38
FIDUCIALTRUE
DISTANCE_PCB_BARE_MODULE_TOP_LEFTNone
DISTANCE_PCB_BARE_MODULE_BOTTOM_RIGHTNone
AVERAGE_THICKNESSNone
STD_DEVIATION_THICKNESSNone
THICKNESS_VARIATION_PICKUP_AREANone
THICKNESS_INCLUDING_POWER_CONNECTORNone
HV_CAPACITOR_THICKNESSNone
FIDUCIALNone
MODULE/ASSEMBLY67506ad04457d9315d982a1e1.0164657cef8d79bac1f3f00581
mts2024-12-13 14:52:11.391000
cts2024-12-13 14:52:11.391000
rev0
rawHash4fcec43bd56291086cfdf05390ba19f4
stageMODULE/ASSEMBLY

ProductionDB Record

id675c5791250da57bff9e5072
stateready
stateTs2024-12-13T15:49:37.513Z
stateUserIdentity3182-7646-1
date2024-12-13T14:52:00.000Z
testType
id627a356dba163f000ab63233
codeQUAD_MODULE_METROLOGY
nameQuad Module Metrology
stateactive
institution
id5d41d8ddf6e07b000a559aee
codeINFN_MILANO
nameINFN Milano
user
id60e59f40049e18000a3aec94
userIdentity3182-7646-1
firstNameAnna
middleNameRaquel
lastNamePetri
runNumber675c4a1c6496fd408f976112
passedFalse
problemsFalse
properties
codenamedataTypevalueTyperequiredvaluerangeMinrangeMax
ANALYSIS_VERSIONAnalysis VersionstringsingleFalse2.2.9NoneNone
MEASUREMENT_DATEDate measurement performeddatetimeNoneFalse2024-12-13T14:48:36.000+00:00NoneNone
OPERATOR_IDENTITYOperator identitystringsingleFalseNoneNoneNone
results
  • codeAVERAGE_THICKNESS
    nameAverage module thickness at FE chip pick-up areas, 1 per FE [μm]
    dataTypefloat
    valueTypearray
    arrayDimensions1
    additionalFalse
    value
    • 662
    • 669
    • 651
    • 624
    associateChildNone
  • codeDISTANCE_PCB_BARE_MODULE_BOTTOM_RIGHT
    nameDistance of PCB fiducial to bare module fiducial bottom right (x and y) [µm]
    order1
    dataTypefloat
    valueTypearray
    arrayDimensions1
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value
    • 2.184
    • 0.905
    associateChildNone
  • codeDISTANCE_PCB_BARE_MODULE_TOP_LEFT
    nameDistance of PCB fiducial to bare module fiducial top left (x and y) [µm]
    order1
    dataTypefloat
    valueTypearray
    arrayDimensions1
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value
    • 2.201
    • 0.68
    associateChildNone
  • codeFIDUCIAL
    nameFiducial
    dataTypeboolean
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    valueTrue
    associateChildNone
  • codeHV_CAPACITOR_THICKNESS
    nameHV capacitor thickness [µm]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    value2380
    associateChildNone
  • codeSTD_DEVIATION_THICKNESS
    nameStd deviation of module thickness at FE chip pick-up area, 1 per FE [μm]
    dataTypefloat
    valueTypearray
    arrayDimensions1
    additionalFalse
    value
    • 0
    • 0
    • 0
    • 0
    associateChildNone
  • codeTHICKNESS_INCLUDING_POWER_CONNECTOR
    nameThickness including the black body of power connector (excluding pins) [µm]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    value1995
    associateChildNone
  • codeTHICKNESS_VARIATION_PICKUP_AREA
    nameThickness variation of the 4 pick-up areas [µm]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    value45
    associateChildNone
cts2024-12-13T15:49:37.513Z
sys
cts2024-12-13T15:49:37.513Z
mts2024-12-13T15:49:38.160Z
rev1
defects
commentsNone
attachments
codedateTimetitledescriptioncontentTypetypebinaryStoreg02filenameuser
0733fc3baf733c5f73fc1963ebda92c22024-12-13T15:49:37.706ZRAWRAWapplication/jsonfileTrue20UPGM23211208_MODULE__ASSEMBLY_QUAD_MODULE_METROLOGY_675c5791250da57bff9e5072_675c4a1b6496fd408f976111.json
id60e59f40049e18000a3aec94
userIdentity3182-7646-1
firstNameAnna
middleNameRaquel
lastNamePetri
components
idcodestatestateTsstateUserIdentitydummycompletedcompletedTscompletedUserIdentitytrashedtrashedTstrashedUserIdentityserialNumberalternativeIdentifierprojectsubprojectcomponentTypetypepropertiestestedAtStageinstitution
67506ad04457d9315d982a1ed84b34080f99885dcb0690f31d9f0438ready2024-12-04T14:44:32.072Z1291-1033-1FalseFalseNoneNoneFalseNoneNone20UPGM23211208None
codeP
namePixels
codePG
namePixel general
codeMODULE
nameModule
codeOUTER_SYSTEM_QUAD_MODULE
nameOuter system quad module
  • codeFECHIP_VERSION
    nameFE chip version
    dataTypecodeTable
    requiredTrue
    defaultFalse
    valueITkpix_v2
    codeTable
    codevalue
    0RD53A
    1ITkpix_v1
    2ITkpix_v1.1
    3ITkpix_v2
    9No FE chip
  • codeORIENTATION
    namePCB-Bare Orientation isNormal
    dataTypeboolean
    requiredTrue
    defaultFalse
    valueTrue
  • codeIS_PREPRODUCTION_MODULE
    nameIs preproduction module
    dataTypeboolean
    requiredFalse
    defaultFalse
    valueTrue
codeMODULE/ASSEMBLY
nameBare module to module PCB assembly
order1
initialFalse
finalFalse
codeINFN_MILANO
nameINFN Milano

 Current Stage: Module PCB tab cutting

Test Type Local Result
Mass Measurement
(MASS_MEASUREMENT)
No TestRun!
Module PCB Tab Cutting Information
(CUTTER_PCB_TAB)
No TestRun!
Visual Inspection
(VISUAL_INSPECTION)
No TestRun!
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No TestRun!
IV measurement
(IV_MEASURE)
No TestRun!

 Candidate TestRuns of this Stage

LDB ID TestRun Code QC Passed Inspector Measurement Date Analysis Date Analysis Version Tags QC Registration
67aa18…fa7b5d MASS_MEASUREMENT Pass AnnaRaquel Petri N/A 10 months ago 1 No tags Selected
675c4a…976112 QUAD_MODULE_METROLOGY Fail AnnaRaquel Petri a year ago a year ago 2.2.9 No tags Selected
675c49…976110 VISUAL_INSPECTION Pass AnnaRaquel Petri a year ago a year ago 2.2.9 No tags Selected

Past QC Stages and Results

Module reception (MODULE/RECEPTION)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Module Complete (MODULE/COMPLETE)

Module graveyard - damaged, impossible to recover (MODULE/GRAVEYARD)

Stage for QA modules and others not to be considered in yield calculation (MODULE/NOTCONSIDEREDINYIELDS)

Module unhappy - failed test, needs investigation (MODULE/UNHAPPY)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A

Ranking of the module (MODULE/QC_STATUS)

Test Local Result ProdDB Record
Module ranking
(RANKING)
No result N/A

Final flatness measurement (MODULE/FINAL_METROLOGY)

Test Local Result ProdDB Record
Flatness
(FLATNESS)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Final Cold (MODULE/FINAL_COLD)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered

Final Warm (MODULE/FINAL_WARM)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Long Term Stability Test (MODULE/LONG_TERM_STABILITY_TEST)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Longterm stability DCS
(LONG_TERM_STABILITY_DCS)
Registered Registered

Thermal Cycles (MODULE/THERMAL_CYCLES)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
Flatness
(FLATNESS)
No result N/A
IV measurement
(IV_MEASURE)
Registered Registered
Thermal Cycling
(THERMAL_CYCLING)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered

Post-Parylene Cold (MODULE/POST_PARYLENE_COLD)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Post-Parylene Warm (MODULE/POST_PARYLENE_WARM)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Wirebond Protection (alt) (MODULE/WIREBOND_PROTECTION)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Mass Measurement
(MASS_MEASUREMENT)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
No result N/A
Wire bonding protection roof envelope
(WP_ENVELOPE)
No result N/A

Parylene Unmasking (MODULE/PARYLENE_UNMASKING)

Test Local Result ProdDB Record
Parylene (de-)masking
(DE_MASKING)
Registered Registered
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
Flatness
(FLATNESS)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered

Parylene Coating (MODULE/PARYLENE_COATING)

Test Local Result ProdDB Record
Parylene Properties
(PARYLENE)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Parylene Masking (MODULE/PARYLENE_MASKING)

Test Local Result ProdDB Record
Parylene (de-)masking
(DE_MASKING)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered

Initial Cold (MODULE/INITIAL_COLD)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A

QC cross-check (module swapping) (MODULE/QC_CROSSCHECK)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A

Initial Warm (MODULE/INITIAL_WARM)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered

Wire Bonding (MODULE/WIREBONDING)

Test Local Result ProdDB Record
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered
Wirebond pull test
(WIREBOND_PULL_TEST)
Registered Registered
Wirebonding Information
(WIREBONDING)
No result N/A

Bare module to module PCB assembly (MODULE/ASSEMBLY)

Test Local Result ProdDB Record
Flatness
(FLATNESS)
No result N/A
Glue Information Module+Flex Attach
(GLUE_MODULE_FLEX_ATTACH)
No result N/A
Mass Measurement
(MASS_MEASUREMENT)
Registered Registered
Quad Module Metrology
(QUAD_MODULE_METROLOGY)
Registered Registered
Triplet Module Metrology
(TRIPLET_METROLOGY)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered

Initial state to associate flex to bare module (MODULE/INIT)

LocalDB Test ID Stage Test Name Inspector Measurement Date Analysis Date Tags QC Registration
6846f7…66a460 MODULE/RECEPTION IV_MEASURE stefaniaSpagnolo 6 months ago 6 months ago No tags Selected
6846fb…66a830 MODULE/RECEPTION E_SUMMARY stefaniaSpagnolo N/A 6 months ago No tags Selected
67d30a…ba040f MODULE/FINAL_COLD IV_MEASURE GiuseppeCarratta 9 months ago 8 months ago No tags Selected
67fd11…f41e17 MODULE/FINAL_COLD E_SUMMARY GiuseppeCarratta N/A 8 months ago No tags Selected
67d2d5…b9f562 MODULE/FINAL_WARM IV_MEASURE GiuseppeCarratta 9 months ago 8 months ago No tags Selected
67fd11…f42281 MODULE/FINAL_WARM E_SUMMARY GiuseppeCarratta N/A 8 months ago No tags Selected
67d299…b9ef41 MODULE/LONG_TERM_STABILITY_TEST LONG_TERM_STABILITY_DCS CarlaSbarra 9 months ago 9 months ago No tags Selected
67d156…74118a MODULE/THERMAL_CYCLES IV_MEASURE CarlaSbarra 9 months ago 9 months ago No tags Selected
67d019…73fcfa MODULE/THERMAL_CYCLES THERMAL_CYCLING CarlaSbarra 9 months ago 9 months ago No tags Selected
67d83f…ba5377 MODULE/THERMAL_CYCLES E_SUMMARY CarlaSbarra N/A 9 months ago No tags Selected
67d832…ba4696 MODULE/POST_PARYLENE_COLD IV_MEASURE CarlaSbarra 9 months ago 9 months ago No tags Selected
67d83d…ba5195 MODULE/POST_PARYLENE_COLD E_SUMMARY CarlaSbarra N/A 9 months ago No tags Selected
67b5f2…75cda2 MODULE/POST_PARYLENE_WARM IV_MEASURE AnnaRaquel Petri 10 months ago 9 months ago No tags Selected
67c5e0…4d95d0 MODULE/POST_PARYLENE_WARM E_SUMMARY AnnaRaquel Petri N/A 9 months ago No tags Selected
67c5d1…907aff MODULE/PARYLENE_UNMASKING DE_MASKING AnnaRaquel Petri 10 months ago 9 months ago No tags Selected
67c5d1…907aed MODULE/PARYLENE_COATING PARYLENE AnnaRaquel Petri 10 months ago 9 months ago No tags Selected
67c5d0…907adc MODULE/PARYLENE_MASKING DE_MASKING AnnaRaquel Petri 10 months ago 9 months ago No tags Selected
67a3a5…86e065 MODULE/PARYLENE_MASKING VISUAL_INSPECTION AnnaRaquel Petri 10 months ago 9 months ago No tags Selected
67aa18…fa7b5d MODULE/ASSEMBLY MASS_MEASUREMENT AnnaRaquel Petri N/A 10 months ago No tags Selected
679cd6…86c209 MODULE/INITIAL_WARM IV_MEASURE AnnaRaquel Petri 11 months ago 10 months ago No tags Selected
679cfc…86c9f0 MODULE/INITIAL_WARM E_SUMMARY AnnaRaquel Petri N/A 10 months ago No tags Selected
67a387…86d7d8 MODULE/WIREBONDING VISUAL_INSPECTION AnnaRaquel Petri 10 months ago 10 months ago No tags Selected
675c59…976247 MODULE/WIREBONDING WIREBOND_PULL_TEST AnnaRaquel Petri a year ago 10 months ago No tags Selected
675c4a…976112 MODULE/ASSEMBLY QUAD_MODULE_METROLOGY AnnaRaquel Petri a year ago a year ago No tags Selected
675c49…976110 MODULE/ASSEMBLY VISUAL_INSPECTION AnnaRaquel Petri a year ago a year ago No tags Selected
Stage Tests
MODULE/INIT
MODULE/ASSEMBLY
  • Mass Measurement  (MASS_MEASUREMENT)
  • Glue Information Module+Flex Attach  (GLUE_MODULE_FLEX_ATTACH)
  • Triplet Module Metrology  (TRIPLET_METROLOGY)
  • Visual Inspection  (VISUAL_INSPECTION)
  • Flatness  (FLATNESS)
  • Quad Module Metrology  (QUAD_MODULE_METROLOGY)
MODULE/WIREBONDING
  • Wirebonding Information  (WIREBONDING)
  • Wirebond pull test  (WIREBOND_PULL_TEST)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/INITIAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/QC_CROSSCHECK
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/INITIAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/PARYLENE_MASKING
  • Visual Inspection  (VISUAL_INSPECTION)
  • Parylene (de-)masking  (DE_MASKING)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/PARYLENE_COATING
  • Parylene Properties  (PARYLENE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/PARYLENE_UNMASKING
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Parylene (de-)masking  (DE_MASKING)
MODULE/WIREBOND_PROTECTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Wire bonding protection roof envelope  (WP_ENVELOPE)
  • Mass Measurement  (MASS_MEASUREMENT)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
MODULE/POST_PARYLENE_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/POST_PARYLENE_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/THERMAL_CYCLES
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Thermal Cycling  (THERMAL_CYCLING)
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
MODULE/LONG_TERM_STABILITY_TEST
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Longterm stability DCS  (LONG_TERM_STABILITY_DCS)
MODULE/FINAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/FINAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/FINAL_METROLOGY
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/QC_STATUS
  • Module ranking  (RANKING)
MODULE/UNHAPPY
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/NOTCONSIDEREDINYIELDS
MODULE/GRAVEYARD
MODULE/COMPLETE
MODULE/RECEPTION
  • Visual Inspection  (VISUAL_INSPECTION)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/TAB_CUTTING
  • Mass Measurement  (MASS_MEASUREMENT)
  • Module PCB Tab Cutting Information  (CUTTER_PCB_TAB)
  • Visual Inspection  (VISUAL_INSPECTION)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
LLS/PRE_TC_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/PRE_TC_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/POST_TC_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/POST_TC_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/RECEPTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
OB_LOADED_MODULE_CELL/INIT
OB_LOADED_MODULE_CELL/ASSEMBLY
OB_LOADED_MODULE_CELL/THERMAL_CYCLES
OB_LOADED_MODULE_CELL/FINAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/FINAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/THERMAL_COLD
  • Thermal Measure  (THERMAL_PERFORMANCE)
OB_LOADED_MODULE_CELL/THERMAL_WARM
  • Thermal Measure  (THERMAL_PERFORMANCE)
OB_LOADED_MODULE_CELL/ENVELOPE_CHECK
OB_LOADED_MODULE_CELL/QC_STATUS
OB_LOADED_MODULE_CELL/UNHAPPY
OB_LOADED_MODULE_CELL/COMPLETE
OB_LOADED_MODULE_CELL/RECEPTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/TAB_CUTTING
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Module PCB Tab Cutting Information  (CUTTER_PCB_TAB)
OB_LOADED_MODULE_CELL/PIGTAIL_INSERTION
Back to top page of this component