20UPGM23210494 (PPPV2_10)

MODULE/QC_STATUS

Component Information

Serial Number 20UPGM23210494
ProdDB ID  7e48ee…e97925
LocalDB ID 6710b90207e8e500432c562a
Component Type MODULE
Parents No match.
Children 20UPGB43200014 Bare Module 20UPGPQ2210494 PCB 20UPGFC0133415 FE Chip 20UPGFC0133463 FE Chip 20UPGFC0133543 FE Chip 20UPGFC0133479 FE Chip
Flags
Distribution of chips on wafer

 Properties

Item Value
PCB-Bare Orientation isNormal True
FE chip version 3
Wirebond protection roof presence True
IREFTRIM_FE1 deleted None
IREFTRIM_FE2 deleted None
IREFTRIM_FE3 deleted None
IREFTRIM_FE4 deleted None
Alternative ID PPPV2_10
Rank None

 Comments


Test: WIREBONDING QC Passed

(Stage: MODULE/WIREBONDING)


Result of Wirebonding Information

Scan

Key Data
component id 6710b90207e8e500432c562a
Stage MODULE/WIREBONDING
test Type WIREBONDING
institute 64657cef8d79bac1f3f00584
user FrancescoCrescioli

Result

Key Data
properties {'BONDING_JIG': '', 'BOND_PROGRAM': '', 'BOND_WIRE_BATCH': '', 'MACHINE': 'Bondtec 5832', 'MEASUREMENT_DATE': '2024-11-19T10:01:00.000+00:00', 'OPERATOR_IDENTITY': ''}
HUMIDITY 40
IREF_TRIM_BIT_1 12
IREF_TRIM_BIT_2 14
IREF_TRIM_BIT_3 12
IREF_TRIM_BIT_4 10
REWORKED_WIRE_BONDS 2
TEMPERATURE 20

Property

Key Data

RAW Results Record

Download RAW
_id67878ed73b12e82a003d615e
raw
serialNumbertestTyperesultsstagecomponentdbVersionaddressusersys
20UPGM23210494WIREBONDING
property
MACHINEBondtec 5832
BOND_WIRE_BATCH
BOND_PROGRAM
BONDING_JIG
MEASUREMENT_DATENone
OPERATOR_IDENTITY
comment
Measurements
HUMIDITY40.0
TEMPERATURE20.0
REWORKED_WIRE_BONDS2
IREF_TRIM_BIT_112
IREF_TRIM_BIT_214
IREF_TRIM_BIT_312
IREF_TRIM_BIT_410
Metadata
LocalDB version2.2.39-rc1
InstitutionLPNHE
ModuleSN20UPGM23210494
TimeStart1732010460
TimeEnd1732032060
MODULE/WIREBONDING6710b90207e8e500432c562a1.0164657cef8d79bac1f3f00584nbogatyrev
mts2025-01-15 10:32:55.407000
cts2025-01-15 10:32:55.407000
rev0
rawHash250bd5961679af42bffbcdf4ff259512
stageMODULE/WIREBONDING

ProductionDB Record

id67881ada5ed43ee40a83cd9a
stateready
stateTs2025-01-15T20:30:18.795Z
stateUserIdentity9086-39-1
date2025-01-15T10:32:00.000Z
testType
id5d13255102c38f00090aab47
codeWIREBONDING
nameWirebonding Information
stateactive
institution
id5d42fb891fd678000a409866
codeLPNHE
nameLaboratoire de Physique Nucléaire et de Hautes Energies
user
id5e98594f8bc0cb000ba8d3a8
userIdentity9086-39-1
firstNameFrancesco
middleName
lastNameCrescioli
runNumber67878ed93b12e82a003d615f
passedTrue
problemsFalse
properties
  • codeBONDING_JIG
    nameBonding Jig
    dataTypestring
    valueTypesingle
    requiredFalse
    value
  • codeBOND_PROGRAM
    nameBond Program
    dataTypestring
    valueTypesingle
    requiredFalse
    value
  • codeBOND_WIRE_BATCH
    nameBond wire batch
    dataTypestring
    valueTypesingle
    requiredFalse
    value
  • codeMACHINE
    nameMachine Used
    dataTypestring
    valueTypesingle
    requiredFalse
    valueBondtec 5832
    rangeMinNone
    rangeMaxNone
  • codeMEASUREMENT_DATE
    nameDate wirebonding performed
    dataTypedatetime
    valueTypeNone
    requiredFalse
    value2024-11-19T10:01:00.000+00:00
    rangeMinNone
    rangeMaxNone
  • codeOPERATOR_IDENTITY
    nameOperator Name
    dataTypestring
    valueTypesingle
    requiredFalse
    value
    rangeMinNone
    rangeMaxNone
results
  • codeHUMIDITY
    nameHumidity (%)
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    value40
    associateChildNone
  • codeIREF_TRIM_BIT_1
    nameIREF Trim Bit FE1 (as bonded)
    dataTypeinteger
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    value12
    associateChildNone
  • codeIREF_TRIM_BIT_2
    nameIREF Trim Bit FE2 (as bonded)
    dataTypeinteger
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    value14
    associateChildNone
  • codeIREF_TRIM_BIT_3
    nameIREF Trim Bit FE3 (as bonded)
    dataTypeinteger
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    value12
    associateChildNone
  • codeIREF_TRIM_BIT_4
    nameIREF Trim Bit FE4 (as bonded)
    dataTypeinteger
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    value10
    associateChildNone
  • codeREWORKED_WIRE_BONDS
    nameNumber of reworked wirebonds
    dataTypecodeTable
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    value2
    associateChildNone
    codeTable
    codevalue
    1none
    2few (1-5)
    3many (>5)
  • codeTEMPERATURE
    nameTemperature (degC)
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    value20
    associateChildNone
cts2025-01-15T20:30:18.795Z
sys
cts2025-01-15T20:30:18.795Z
mts2025-01-15T20:30:19.168Z
rev1
defects
commentsNone
attachments
codedateTimetitledescriptioncontentTypetypebinaryStoreg02filenameuser
abde361bfe4e08f4f7cf443a979a214f2025-01-15T20:30:18.970ZRAWRAWapplication/jsonfileTrue20UPGM23210494_MODULE__WIREBONDING_WIREBONDING_67881ada5ed43ee40a83cd9a_67878ed73b12e82a003d615e.json
id5e98594f8bc0cb000ba8d3a8
userIdentity9086-39-1
firstNameFrancesco
middleName
lastNameCrescioli
components
idcodestatestateTsstateUserIdentitydummycompletedcompletedTscompletedUserIdentitytrashedtrashedTstrashedUserIdentityserialNumberalternativeIdentifierprojectsubprojectcomponentTypetypepropertiestestedAtStageinstitution
6710b90207e8e500432c562a7e48eeedbcd3d42a9f7b4cfc5de97925ready2024-10-17T07:13:06.283Z9086-39-1FalseFalseNoneNoneFalseNoneNone20UPGM23210494PPPV2_10
codeP
namePixels
codePG
namePixel general
codeMODULE
nameModule
codeOUTER_SYSTEM_QUAD_MODULE
nameOuter system quad module
  • codeORIENTATION
    namePCB-Bare Orientation isNormal
    dataTypeboolean
    requiredTrue
    defaultFalse
    valueTrue
  • codeFECHIP_VERSION
    nameFE chip version
    dataTypecodeTable
    requiredTrue
    defaultFalse
    valueITkpix_v2
    codeTable
    codevalue
    0RD53A
    1ITkpix_v1
    2ITkpix_v1.1
    3ITkpix_v2
    9No FE chip
  • codeROOF
    nameWirebond protection roof presence
    dataTypeboolean
    requiredFalse
    defaultFalse
    valueTrue
  • codeIREFTRIM_FE1
    nameIREFTRIM_FE1
    valueNone
  • codeIREFTRIM_FE2
    nameIREFTRIM_FE2
    valueNone
  • codeIREFTRIM_FE3
    nameIREFTRIM_FE3
    valueNone
  • codeIREFTRIM_FE4
    nameIREFTRIM_FE4
    valueNone
  • codeALTERNATIVE_IDENTIFIER
    nameAlternative ID
    dataTypestring
    requiredFalse
    defaultTrue
    valuePPPV2_10
codeMODULE/WIREBONDING
nameWire Bonding
order2
initialFalse
finalFalse
codeLPNHE
nameLaboratoire de Physique Nucléaire et de Hautes Energies

 Current Stage: Ranking of the module

Test Type Local Result
Module ranking
(RANKING)
No TestRun!

 Candidate TestRuns of this Stage

LDB ID TestRun Code QC Passed Inspector Measurement Date Analysis Date Analysis Version Tags QC Registration
678790…85689e VISUAL_INSPECTION Pass FrancescoCrescioli 11 months ago 11 months ago 2.3.0 No tags Selected
673c67…9aaba9 WIREBOND_PULL_TEST Pass FrancescoCrescioli a year ago 11 months ago 2.2.9rc4 No tags Selected
67878e…3d615f WIREBONDING Pass FrancescoCrescioli a year ago 11 months ago No tags Selected

Past QC Stages and Results

Final flatness measurement (MODULE/FINAL_METROLOGY)

Test Local Result ProdDB Record
Flatness
(FLATNESS)
Registered Registered

Final Cold (MODULE/FINAL_COLD)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered

Final Warm (MODULE/FINAL_WARM)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Long Term Stability Test (MODULE/LONG_TERM_STABILITY_TEST)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered
Longterm stability DCS
(LONG_TERM_STABILITY_DCS)
Registered Registered

Thermal Cycles (MODULE/THERMAL_CYCLES)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
Flatness
(FLATNESS)
No result N/A
IV measurement
(IV_MEASURE)
Registered Registered
Thermal Cycling
(THERMAL_CYCLING)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Post-Parylene Cold (MODULE/POST_PARYLENE_COLD)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Post-Parylene Warm (MODULE/POST_PARYLENE_WARM)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Wirebond Protection (alt) (MODULE/WIREBOND_PROTECTION)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered
Mass Measurement
(MASS_MEASUREMENT)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered
Wire bonding protection roof envelope
(WP_ENVELOPE)
Registered Registered

Parylene Unmasking (MODULE/PARYLENE_UNMASKING)

Test Local Result ProdDB Record
Parylene (de-)masking
(DE_MASKING)
Registered Registered
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
Flatness
(FLATNESS)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered

Parylene Coating (MODULE/PARYLENE_COATING)

Test Local Result ProdDB Record
Parylene Properties
(PARYLENE)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered

Parylene Masking (MODULE/PARYLENE_MASKING)

Test Local Result ProdDB Record
Parylene (de-)masking
(DE_MASKING)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered

Initial Cold (MODULE/INITIAL_COLD)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered

QC cross-check (module swapping) (MODULE/QC_CROSSCHECK)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A

Initial Warm (MODULE/INITIAL_WARM)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered

Wire Bonding (MODULE/WIREBONDING)

Test Local Result ProdDB Record
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered
Wirebond pull test
(WIREBOND_PULL_TEST)
Registered Registered
Wirebonding Information
(WIREBONDING)
Registered Registered

Bare module to module PCB assembly (MODULE/ASSEMBLY)

Test Local Result ProdDB Record
Flatness
(FLATNESS)
Registered Registered
Glue Information Module+Flex Attach
(GLUE_MODULE_FLEX_ATTACH)
Registered Registered
Mass Measurement
(MASS_MEASUREMENT)
Registered Registered
Quad Module Metrology
(QUAD_MODULE_METROLOGY)
Registered Registered
Triplet Module Metrology
(TRIPLET_METROLOGY)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered

Initial state to associate flex to bare module (MODULE/INIT)

LocalDB Test ID Stage Test Name Inspector Measurement Date Analysis Date Tags QC Registration
67d2b9…adb987 MODULE/FINAL_METROLOGY FLATNESS FrancescoCrescioli 9 months ago 9 months ago No tags Selected
67d2b5…665acb MODULE/FINAL_COLD VISUAL_INSPECTION FrancescoCrescioli 9 months ago 9 months ago No tags Selected
67d2bb…bd047f MODULE/FINAL_COLD IV_MEASURE FrancescoCrescioli N/A 9 months ago No tags Selected
67d2b5…adb981 MODULE/FINAL_COLD E_SUMMARY FrancescoCrescioli N/A 9 months ago No tags Selected
67d147…ad9a9d MODULE/FINAL_WARM IV_MEASURE FrancescoCrescioli N/A 9 months ago No tags Selected
67d14f…982960 MODULE/FINAL_WARM E_SUMMARY FrancescoCrescioli N/A 9 months ago No tags Selected
67d16e…bcf94b MODULE/LONG_TERM_STABILITY_TEST LONG_TERM_STABILITY_DCS FrancescoCrescioli 9 months ago 9 months ago No tags Selected
67d16e…3f5291 MODULE/LONG_TERM_STABILITY_TEST IV_MEASURE FrancescoCrescioli N/A 9 months ago No tags Selected
67d16e…adb2e3 MODULE/LONG_TERM_STABILITY_TEST E_SUMMARY FrancescoCrescioli N/A 9 months ago No tags Selected
67caaf…66396b MODULE/THERMAL_CYCLES IV_MEASURE FrancescoCrescioli N/A 9 months ago No tags Selected
67c9a1…2a6218 MODULE/THERMAL_CYCLES THERMAL_CYCLING FrancescoCrescioli 9 months ago 9 months ago No tags Selected
67cb09…663f73 MODULE/THERMAL_CYCLES E_SUMMARY FrancescoCrescioli N/A 9 months ago No tags Selected
67afd5…17a55c MODULE/WIREBOND_PROTECTION IV_MEASURE FrancescoCrescioli N/A 9 months ago No tags Selected
67c1f1…8172f1 MODULE/WIREBOND_PROTECTION VISUAL_INSPECTION FrancescoCrescioli 10 months ago 9 months ago No tags Selected
67c1e8…d9e5da MODULE/WIREBOND_PROTECTION MASS_MEASUREMENT FrancescoCrescioli 10 months ago 9 months ago No tags Selected
67c1ea…3583c8 MODULE/WIREBOND_PROTECTION WP_ENVELOPE FrancescoCrescioli 10 months ago 9 months ago No tags Selected
67c1f0…61e34c MODULE/WIREBOND_PROTECTION E_SUMMARY FrancescoCrescioli N/A 9 months ago No tags Selected
6796bb…07f0a7 MODULE/POST_PARYLENE_WARM IV_MEASURE FrancescoCrescioli N/A 10 months ago No tags Selected
679763…a6b5f4 MODULE/POST_PARYLENE_WARM E_SUMMARY FrancescoCrescioli N/A 10 months ago No tags Selected
679a04…7a8659 MODULE/PARYLENE_UNMASKING DE_MASKING FrancescoCrescioli 11 months ago 10 months ago No tags Selected
679a40…7bde60 MODULE/PARYLENE_UNMASKING VISUAL_INSPECTION FrancescoCrescioli 11 months ago 10 months ago No tags Selected
679a03…082385 MODULE/PARYLENE_COATING VISUAL_INSPECTION FrancescoCrescioli 11 months ago 10 months ago No tags Selected
67c01c…715f14 MODULE/PARYLENE_COATING PARYLENE FrancescoCrescioli 10 months ago 10 months ago No tags Selected
67890b…856e5f MODULE/PARYLENE_MASKING VISUAL_INSPECTION FrancescoCrescioli 11 months ago 11 months ago No tags Selected
673cb3…b47198 MODULE/INITIAL_COLD IV_MEASURE FrancescoCrescioli N/A 11 months ago No tags Selected
677e97…54dfe4 MODULE/INITIAL_COLD E_SUMMARY FrancescoCrescioli N/A 11 months ago No tags Selected
6728b7…ef0423 MODULE/INITIAL_WARM IV_MEASURE FrancescoCrescioli N/A 11 months ago No tags Selected
677e45…c1e283 MODULE/INITIAL_WARM E_SUMMARY FrancescoCrescioli N/A 11 months ago No tags Selected
678790…85689e MODULE/WIREBONDING VISUAL_INSPECTION FrancescoCrescioli 11 months ago 11 months ago No tags Selected
673c67…9aaba9 MODULE/WIREBONDING WIREBOND_PULL_TEST FrancescoCrescioli a year ago 11 months ago No tags Selected
67878e…3d615f MODULE/WIREBONDING WIREBONDING FrancescoCrescioli a year ago 11 months ago No tags Selected
678629…e2df31 MODULE/ASSEMBLY GLUE_MODULE_FLEX_ATTACH FrancescoCrescioli N/A 11 months ago No tags Selected
678624…7a2f4c MODULE/ASSEMBLY FLATNESS FrancescoCrescioli N/A 11 months ago No tags Selected
678160…28b2c2 MODULE/ASSEMBLY QUAD_MODULE_METROLOGY PaulMickael Chabrillat N/A 11 months ago No tags Selected
671b79…945c16 MODULE/ASSEMBLY VISUAL_INSPECTION FrancescoCrescioli a year ago 11 months ago No tags Selected
6710ce…ad9281 MODULE/ASSEMBLY MASS_MEASUREMENT FrancescoCrescioli N/A 11 months ago No tags Selected
Stage Tests
MODULE/INIT
MODULE/ASSEMBLY
  • Mass Measurement  (MASS_MEASUREMENT)
  • Glue Information Module+Flex Attach  (GLUE_MODULE_FLEX_ATTACH)
  • Triplet Module Metrology  (TRIPLET_METROLOGY)
  • Visual Inspection  (VISUAL_INSPECTION)
  • Flatness  (FLATNESS)
  • Quad Module Metrology  (QUAD_MODULE_METROLOGY)
MODULE/WIREBONDING
  • Wirebonding Information  (WIREBONDING)
  • Wirebond pull test  (WIREBOND_PULL_TEST)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/INITIAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/QC_CROSSCHECK
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/INITIAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/PARYLENE_MASKING
  • Visual Inspection  (VISUAL_INSPECTION)
  • Parylene (de-)masking  (DE_MASKING)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/PARYLENE_COATING
  • Parylene Properties  (PARYLENE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/PARYLENE_UNMASKING
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Parylene (de-)masking  (DE_MASKING)
MODULE/WIREBOND_PROTECTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Wire bonding protection roof envelope  (WP_ENVELOPE)
  • Mass Measurement  (MASS_MEASUREMENT)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
MODULE/POST_PARYLENE_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/POST_PARYLENE_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/THERMAL_CYCLES
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Thermal Cycling  (THERMAL_CYCLING)
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
MODULE/LONG_TERM_STABILITY_TEST
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Longterm stability DCS  (LONG_TERM_STABILITY_DCS)
MODULE/FINAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/FINAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/FINAL_METROLOGY
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/QC_STATUS
  • Module ranking  (RANKING)
MODULE/UNHAPPY
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/NOTCONSIDEREDINYIELDS
MODULE/GRAVEYARD
MODULE/COMPLETE
MODULE/RECEPTION
  • Visual Inspection  (VISUAL_INSPECTION)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/TAB_CUTTING
  • Mass Measurement  (MASS_MEASUREMENT)
  • Module PCB Tab Cutting Information  (CUTTER_PCB_TAB)
  • Visual Inspection  (VISUAL_INSPECTION)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
LLS/PRE_TC_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/PRE_TC_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/POST_TC_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/POST_TC_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/RECEPTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
OB_LOADED_MODULE_CELL/INIT
OB_LOADED_MODULE_CELL/ASSEMBLY
OB_LOADED_MODULE_CELL/THERMAL_CYCLES
OB_LOADED_MODULE_CELL/FINAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/FINAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/THERMAL_COLD
  • Thermal Measure  (THERMAL_PERFORMANCE)
OB_LOADED_MODULE_CELL/THERMAL_WARM
  • Thermal Measure  (THERMAL_PERFORMANCE)
OB_LOADED_MODULE_CELL/ENVELOPE_CHECK
OB_LOADED_MODULE_CELL/QC_STATUS
OB_LOADED_MODULE_CELL/UNHAPPY
OB_LOADED_MODULE_CELL/COMPLETE
OB_LOADED_MODULE_CELL/RECEPTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/TAB_CUTTING
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Module PCB Tab Cutting Information  (CUTTER_PCB_TAB)
OB_LOADED_MODULE_CELL/PIGTAIL_INSERTION
Back to top page of this component