Top Page > Component List > 20UPGS33303840 > QC Result / BAREMODULERECEPTION / IV_MEASURE
Item | Value |
---|---|
Serial Number | 20UPGS33303840 |
Production DB Component ID | 3e9a2b8494c1b7543c39f9d3a8b1ab8f |
LocalDB Component ID | 66f6bf5913e0b0004328f5da |
Component Type | sensor_tile |
Super-Component | 20UPGB43200112 |
Sub-Components | No match. |
Flags |
Key | Data |
---|---|
QC Passed | True |
Date | 2025-02-03 07:58:55 PST(-0800) |
component ObjectId | 66f6bf5913e0b0004328f5da |
Stage | BAREMODULERECEPTION |
Test Type | IV_MEASURE |
Institute ObjectId | |
User Name | AbdoulayeNDIAYE |
ObjectId of this record | 67a0e7bfd7e33319cc65c992 |
ObjectId of RAW record | None |
Key | Data |
---|---|
ANALYSIS_VERSION | mqat vwebApp SHA:79f25c0 |
HUM | 5.458563219512196 |
TEMP | 20.03 |
BREAKDOWN_VOLTAGE | -999 |
IV_ARRAY | {'voltage': [0, 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 105, 110, 115, 120, 125, 130, 135, 140, 145, 150, 155, 160, 165, 170, 175, 180, 185, 190, 195, 200], 'current': [0.000485585, 0.47815, 0.558127, 0.606772, 0.624518, 0.643079, 0.66055, 0.6753859999999999, 0.689483, 0.703798, 0.717427, 0.730287, 0.742485, 0.755136, 0.7676149999999999, 0.7799349999999999, 0.792497, 0.804836, 0.817249, 0.829186, 0.841875, 0.854696, 0.8671179999999999, 0.880342, 0.89283, 0.905752, 0.9177770000000001, 0.9309499999999999, 0.944078, 0.9562639999999999, 0.9694260000000001, 0.982321, 0.9960559999999999, 1.00905, 1.02278, 1.03588, 1.0504, 1.06494, 1.07928, 1.09433, 1.10907], 'sigma current': [0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0], 'temperature': [20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03], 'humidity': [5.527785, 5.527785, 5.527785, 5.498377, 5.498377, 5.498377, 5.498377, 5.498377, 5.498377, 5.498377, 5.498377, 5.498377, 5.498377, 5.498377, 5.498377, 5.498377, 5.498377, 5.469094, 5.469094, 5.469094, 5.469094, 5.469094, 5.469094, 5.439936, 5.439936, 5.439936, 5.439936, 5.439936, 5.410902, 5.439936, 5.410902, 5.410902, 5.410902, 5.410902, 5.410902, 5.410902, 5.381993, 5.381993, 5.381993, 5.381993, 5.381993]} |
LEAK_CURRENT | 0.841875 |
MAXIMUM_VOLTAGE | 200 |
NO_BREAKDOWN_VOLTAGE_OBSERVED | True |
Test | Local Result | ProdDB Record |
---|---|---|
IV measurement (IV_MEASURE) |
Registered
Jump to the LocalDB Test Record!
|
Registered
Jump to the ITkPD TestRun Page!
|
Test | Local Result | ProdDB Record |
---|---|---|
CV measurement (CV_MEASURE) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
IV measurement (IV_MEASURE) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
Test | Local Result | ProdDB Record |
---|---|---|
CV measurement (CV_MEASURE) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
Inter-pixel capacitance (INTER-PIXEL_CAPACITANCE) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
Inter-pixel resistance (INTER-PIXEL_RESISTANCE) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
IT measurement (IT_MEASURE) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
IV measurement (IV_MEASURE) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
Sensor Metrology: Sensor bow and thickness (SENSOR_METROLOGY) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
Test | Local Result | ProdDB Record |
---|---|---|
CV measurement (CV_MEASURE) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
IV measurement (IV_MEASURE) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
Sensor Metrology: Sensor bow and thickness (SENSOR_METROLOGY) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
Visual inspection (VISUAL_INSPECTION) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
Test | Local Result | ProdDB Record |
---|---|---|
CV measurement (CV_MEASURE) |
Registered
Jump to the LocalDB Test Record!
|
Registered
Jump to the ITkPD TestRun Page!
|
IV measurement (IV_MEASURE) |
Registered
Jump to the LocalDB Test Record!
|
Registered
Jump to the ITkPD TestRun Page!
|
LocalDB Test ID | Stage | Test Name | Inspector | Date | QC Registration |
---|---|---|---|---|---|
67a0e7bfd7e33319cc65c992 | BAREMODULERECEPTION | IV_MEASURE | AbdoulayeNDIAYE | 2025-02-03 07:58:55 PST(-0800) | Selected |
66f6c749db6782004337d25e | sensor_manufacturer | IV_MEASURE | JörnGroße-Knetter | 2024-09-27 07:55:05 PDT(-0700) | Selected |
66f6c48d13e0b00043293999 | sensor_manufacturer | CV_MEASURE | JörnGroße-Knetter | 2024-09-27 07:43:25 PDT(-0700) | Selected |
Stage | Tests |
---|---|
sensor_manufacturer |
|
WAFER_PROCESSING |
|
QA |
|
POST_IRRAD |
|
NOT_USED |
|
BAREMODULEASSEMBLY |
|
BAREMODULERECEPTION |
|
MODULE/INIT |
|
MODULE/ASSEMBLY |
|
MODULE/WIREBONDING |
|
MODULE/INITIAL_WARM |
|
MODULE/QC_CROSSCHECK |
|
MODULE/INITIAL_COLD |
|
MODULE/PARYLENE_MASKING |
|
MODULE/PARYLENE_COATING |
|
MODULE/PARYLENE_UNMASKING |
|
MODULE/POST_PARYLENE_WARM |
|
MODULE/POST_PARYLENE_COLD |
|
MODULE/WIREBOND_PROTECTION |
|
MODULE/THERMAL_CYCLES |
|
MODULE/LONG_TERM_STABILITY_TEST |
|
MODULE/FINAL_WARM |
|
MODULE/FINAL_COLD |
|
MODULE/FINAL_METROLOGY |
|
MODULE/QC_STATUS |
|
MODULE/UNHAPPY |
|
MODULE/NOTCONSIDEREDINYIELDS |
|
MODULE/COMPLETE |
|
MODULE/RECEPTION |
|
MODULE/TAB_CUTTING |
|
OB_LOADED_MODULE_CELL/INIT |
|
OB_LOADED_MODULE_CELL/ASSEMBLY |
|
OB_LOADED_MODULE_CELL/THERMAL_CYCLES |
|
OB_LOADED_MODULE_CELL/FINAL_WARM |
|
OB_LOADED_MODULE_CELL/FINAL_COLD |
|
OB_LOADED_MODULE_CELL/THERMAL_COLD |
|
OB_LOADED_MODULE_CELL/THERMAL_WARM |
|
OB_LOADED_MODULE_CELL/ENVELOPE_CHECK |
|
OB_LOADED_MODULE_CELL/QC_STATUS |
|
OB_LOADED_MODULE_CELL/UNHAPPY |
|
OB_LOADED_MODULE_CELL/COMPLETE |
|
OB_LOADED_MODULE_CELL/RECEPTION |
|
OB_LOADED_MODULE_CELL/TAB_CUTTING |
|
OB_LOADED_MODULE_CELL/PIGTAIL_INSERTION |
|