20UPGS33303759

MODULE/POST_PARYLENE_COLD

Component Information

Serial Number 20UPGS33303759
ProdDB ID  b673f6…d7669f
LocalDB ID 66f6bc8e13e0b0004328e163
Component Type SENSOR_TILE
Parents 20UPGB43200213
Children No match.
Flags

 Properties

Item Value
Main Vendor readonly 3
Sensor Type or Test Structure readonly 3
Version of component production
Scratch id (to be used if not the same as agreed manufacturer ID) 7033
Alternative Identifier V4-2-007033-3-002
Original Manufacturer ID Q2
Breakdown Voltage (-999 if no breakdown occurred) -999
Depletion Voltage (V) 58.62

 Comments


Test: IV_MEASURE QC Passed

(Stage: BAREMODULERECEPTION)


Basic View Only: custom view for this TestRun is not prepared.

Metadata

Key Data
QC Passed True
Date 4 months ago
component ObjectId 66f6bc8e13e0b0004328e163
Stage BAREMODULERECEPTION
Test Type IV_MEASURE
Institute ObjectId
User Name ElizaHoward
ObjectId of this record 688936300f647c459c604632
ObjectId of RAW record None
Tags No tags

Results

Key Data
TEMP 20
HUM 35
ANALYSIS_VERSION mqat vwebApp SHA:54c860b
MEASUREMENT_DATE 2025-07-29T13:37Z
IV_ARRAY {'voltage': [0, 4.8, 9.7, 14.7, 19.8, 24.8, 29.9, 34.8, 39.9, 45, 49.9, 54.9, 59.8, 64.8, 69.9, 74.8, 79.9, 84.8, 89.9, 94.9, 99.9, 104.9, 109.9, 114.8, 119.9, 124.8, 129.9, 134.9, 140, 144.9, 150, 155, 160, 165, 169.9, 175, 180, 185, 190, 195, 199.9], 'current': [0, 0.41929999999999995, 0.46914999999999996, 0.49979999999999997, 0.5206000000000001, 0.5355999999999999, 0.54755, 0.5567000000000001, 0.5636999999999999, 0.56945, 0.5740999999999999, 0.5778999999999997, 0.58095, 0.5838499999999999, 0.5865, 0.5889, 0.5912499999999999, 0.5935499999999999, 0.5957500000000001, 0.5978000000000001, 0.5995999999999998, 0.6014499999999999, 0.6029500000000001, 0.6043000000000001, 0.6055999999999999, 0.6068, 0.6078499999999999, 0.6088000000000001, 0.60975, 0.6106, 0.6113500000000001, 0.6121000000000001, 0.6125999999999998, 0.6134000000000001, 0.6144, 0.61545, 0.61635, 0.6172999999999998, 0.6182500000000001, 0.61925, 0.62025], 'sigma current': [0, 0.0021354156504062643, 0.0014499999999999771, 0.001363818169698577, 0.000969535971483269, 0.0008306623862918121, 0.0006873863542433794, 0.0007483314773547903, 0.0005567764362830145, 0.0005678908345800303, 0.0004898979485566293, 0.0004898979485566429, 0.0004153311931459021, 0.0004500000000000035, 0.00022360679774997914, 0.0003741657386773885, 0.00040311288741493126, 0.0004153311931459021, 0.0003354101966249563, 0.00033166247903552683, 0.0002999999999999892, 0.0003500000000000043, 0.0003499999999999963, 0.0002449489742783452, 0.0002999999999999892, 0.0002449489742782908, 0.00022912878474776676, 0.0002449489742782908, 0.00024999999999997247, 0.00019999999999997795, 0.00022912878474781764, 0.0002000000000000224, 0.00019999999999997795, 0.00020000000000002237, 0.00020000000000002237, 0.00026925824035673265, 0.00022912878474781764, 0.0002449489742783452, 0.000250000000000028, 0.000250000000000028, 0.000250000000000028]}
BREAKDOWN_VOLTAGE -999
LEAK_CURRENT 0.60145
NO_BREAKDOWN_VOLTAGE_OBSERVED True
MAXIMUM_VOLTAGE 199.9

ProductionDB Record

id688936300f647c459c604632
stateready
stateTs2025-07-29T20:59:28.105Z
stateUserIdentity4561-2270-1
date2025-07-29T20:59:00.000Z
testType
id5b1a3abf130f5600054a42a8
codeIV_MEASURE
nameIV measurement
stateactive
institution
id5d318624df98f200097386d5
codeANL
nameArgonne National Laboratory
user
id68755ce03942dab85ad88269
userIdentity4561-2270-1
firstNameEliza
middleName
lastNameHoward
runNumber...
passedTrue
problemsFalse
properties
codenamedataTypevalueTyperequiredvaluerangeMinrangeMax
TEMPTemperature [°C]floatsingleTrue20NoneNone
HUMHumidity [%]floatsingleTrue35NoneNone
ANALYSIS_VERSIONAnalysis VersionstringsingleFalsewebApp SHA:54c860bNoneNone
MEASUREMENT_DATEDate measurement performeddatetimesingleFalse2025-07-29T13:37ZNoneNone
results
  • codeIV_ARRAY
    nameIV data
    dataTypeobject
    valueTypesingle
    arrayDimensions1
    additionalFalse
    value
    voltage
    • 0
    • 4.8
    • 9.7
    • 14.7
    • 19.8
    • 24.8
    • 29.9
    • 34.8
    • 39.9
    • 45
    • 49.9
    • 54.9
    • 59.8
    • 64.8
    • 69.9
    • 74.8
    • 79.9
    • 84.8
    • 89.9
    • 94.9
    • 99.9
    • 104.9
    • 109.9
    • 114.8
    • 119.9
    • 124.8
    • 129.9
    • 134.9
    • 140
    • 144.9
    • 150
    • 155
    • 160
    • 165
    • 169.9
    • 175
    • 180
    • 185
    • 190
    • 195
    • 199.9
    current
    • 0
    • 0.41929999999999995
    • 0.46914999999999996
    • 0.49979999999999997
    • 0.5206000000000001
    • 0.5355999999999999
    • 0.54755
    • 0.5567000000000001
    • 0.5636999999999999
    • 0.56945
    • 0.5740999999999999
    • 0.5778999999999997
    • 0.58095
    • 0.5838499999999999
    • 0.5865
    • 0.5889
    • 0.5912499999999999
    • 0.5935499999999999
    • 0.5957500000000001
    • 0.5978000000000001
    • 0.5995999999999998
    • 0.6014499999999999
    • 0.6029500000000001
    • 0.6043000000000001
    • 0.6055999999999999
    • 0.6068
    • 0.6078499999999999
    • 0.6088000000000001
    • 0.60975
    • 0.6106
    • 0.6113500000000001
    • 0.6121000000000001
    • 0.6125999999999998
    • 0.6134000000000001
    • 0.6144
    • 0.61545
    • 0.61635
    • 0.6172999999999998
    • 0.6182500000000001
    • 0.61925
    • 0.62025
    sigma current
    • 0
    • 0.0021354156504062643
    • 0.0014499999999999771
    • 0.001363818169698577
    • 0.000969535971483269
    • 0.0008306623862918121
    • 0.0006873863542433794
    • 0.0007483314773547903
    • 0.0005567764362830145
    • 0.0005678908345800303
    • 0.0004898979485566293
    • 0.0004898979485566429
    • 0.0004153311931459021
    • 0.0004500000000000035
    • 0.00022360679774997914
    • 0.0003741657386773885
    • 0.00040311288741493126
    • 0.0004153311931459021
    • 0.0003354101966249563
    • 0.00033166247903552683
    • 0.0002999999999999892
    • 0.0003500000000000043
    • 0.0003499999999999963
    • 0.0002449489742783452
    • 0.0002999999999999892
    • 0.0002449489742782908
    • 0.00022912878474776676
    • 0.0002449489742782908
    • 0.00024999999999997247
    • 0.00019999999999997795
    • 0.00022912878474781764
    • 0.0002000000000000224
    • 0.00019999999999997795
    • 0.00020000000000002237
    • 0.00020000000000002237
    • 0.00026925824035673265
    • 0.00022912878474781764
    • 0.0002449489742783452
    • 0.000250000000000028
    • 0.000250000000000028
    • 0.000250000000000028
    dateTime2026-02-18T18:29:48.661Z
    userIdentity1294-8027-1
    associateChildNone
  • codeBREAKDOWN_VOLTAGE
    nameBreakdown voltage [V] (if no breakdown put -999)
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    value-999
    associateChildNone
  • codeLEAK_CURRENT
    nameLeakage current at depletion voltage + 20 (50) V for 3D (planar) sensors [μA]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    value0.60145
    dateTime2026-02-18T18:30:02.455Z
    userIdentity1294-8027-1
    associateChildNone
  • codeNO_BREAKDOWN_VOLTAGE_OBSERVED
    nameNo breakdown voltage observed
    dataTypeboolean
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    valueTrue
    associateChildNone
  • codeMAXIMUM_VOLTAGE
    nameMaximum measured Voltage [V]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value199.9
    associateChildNone
cts2025-07-29T20:59:28.105Z
sys
cts2025-07-29T20:59:28.105Z
mts2026-02-18T18:30:02.460Z
rev2
defects
commentsNone
attachments
components
idcodestatestateTsstateUserIdentitydummycompletedcompletedTscompletedUserIdentitytrashedtrashedTstrashedUserIdentityserialNumberalternativeIdentifierancestorMapprojectsubprojectcomponentTypetypepropertiestestedAtStageinstitution
66f6bc8e13e0b0004328e163b673f673f156c82acd1486b488d7669fready2024-09-27T14:09:18.182Z20-8539-1FalseFalseNoneNoneFalseNoneNone20UPGS33303759V4-2-007033-3-002
parent
component
id67e41733f1be53f1ec4d33a1
coded4ad183d66c03c08c71df399ba3e001f
stateready
stateTs2025-03-26T15:03:15.801Z
stateUserIdentity23-6780-1
dummyFalse
completedFalse
completedTsNone
completedUserIdentityNone
trashedFalse
trashedTsNone
trashedUserIdentityNone
serialNumber20UPGB43200213
alternativeIdentifierNone
project
codeP
namePixels
subproject
codePG
namePixel general
componentType
codeBARE_MODULE
nameBare Module
type
codeQUAD_BARE_MODULE
nameQuad bare module
testedAtStage
codeBAREMODULEASSEMBLY
nameBare module assembly
highestLevelParent
component
id67e41733f1be53f1ec4d33a1
coded4ad183d66c03c08c71df399ba3e001f
stateready
stateTs2025-03-26T15:03:15.801Z
stateUserIdentity23-6780-1
dummyFalse
completedFalse
completedTsNone
completedUserIdentityNone
trashedFalse
trashedTsNone
trashedUserIdentityNone
serialNumber20UPGB43200213
alternativeIdentifierNone
project
codeP
namePixels
subproject
codePG
namePixel general
componentType
codeBARE_MODULE
nameBare Module
type
codeQUAD_BARE_MODULE
nameQuad bare module
testedAtStage
codeBAREMODULEASSEMBLY
nameBare module assembly
codeP
namePixels
codePG
namePixel general
codeSENSOR_TILE
nameSensor Tile
codeOUTER_PIXEL_QUAD_SENSOR_TILE
nameOuter Pixel Quad Sensor Tile
codenamedataTyperequireddefaultvalue
MAIN_VENDORMain VendorintegerTrueFalse3
SENSOR_TYPE_OR_TEST_STRUCTURESensor Type or Test StructureintegerTrueFalse3
VERSIONVersion of componentstringTrueFalseproduction
SENSOR_SCRATCHIDScratch id (to be used if not the same as agreed manufacturer ID)stringFalseFalse7033
MAN_SNOAlternative IdentifierstringTrueTrueV4-2-007033-3-002
MAN_IDOriginal Manufacturer IDstringFalseFalseQ2
BREAKDOWN_VOLTAGEBreakdown Voltage (-999 if no breakdown occurred)floatTrueFalse-999
V_FULLDEPLDepletion Voltage (V)floatTrueFalse58.62
codeBAREMODULERECEPTION
nameBare module reception at ITk institute
order6
initialFalse
finalFalse
codeHPK
nameHamamatsu Photonics K.K (HPK)

 Current Stage: Post-Parylene Cold

Past QC Stages and Results

Post-Parylene Warm (MODULE/POST_PARYLENE_WARM)

Parylene Unmasking (MODULE/PARYLENE_UNMASKING)

Parylene Coating (MODULE/PARYLENE_COATING)

Parylene Masking (MODULE/PARYLENE_MASKING)

Initial Cold (MODULE/INITIAL_COLD)

QC cross-check (module swapping) (MODULE/QC_CROSSCHECK)

Initial Warm (MODULE/INITIAL_WARM)

Wire Bonding (MODULE/WIREBONDING)

Bare module to module PCB assembly (MODULE/ASSEMBLY)

Initial state to associate flex to bare module (MODULE/INIT)

Bare module reception at ITk institute (BAREMODULERECEPTION)

Test Local Result ProdDB Record
IV measurement
(IV_MEASURE)
Registered Registered

Bare Module Assembly (BAREMODULEASSEMBLY)

Not to be used for detector (NOT_USED)

Post Irradiation (POST_IRRAD)

Test Local Result ProdDB Record
CV measurement
(CV_MEASURE)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A

QA at Institutes (QA)

Test Local Result ProdDB Record
CV measurement
(CV_MEASURE)
No result N/A
Inter-pixel capacitance
(INTER-PIXEL_CAPACITANCE)
No result N/A
Inter-pixel resistance
(INTER-PIXEL_RESISTANCE)
No result N/A
IT measurement
(IT_MEASURE)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Sensor Metrology: Sensor bow and thickness
(SENSOR_METROLOGY)
No result N/A

Wafer Processing (dicing, UBM, flip-chip) (WAFER_PROCESSING)

Test Local Result ProdDB Record
CV measurement
(CV_MEASURE)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Sensor Metrology: Sensor bow and thickness
(SENSOR_METROLOGY)
No result N/A
Visual inspection
(VISUAL_INSPECTION)
No result N/A

Sensor Manufacturer (sensor_manufacturer)

Test Local Result ProdDB Record
CV measurement
(CV_MEASURE)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered
LocalDB Test ID Stage Test Name Inspector Measurement Date Analysis Date Tags QC Registration
688936…604632 BAREMODULERECEPTION IV_MEASURE ElizaHoward N/A 4 months ago No tags Selected
66f6c7…37cee4 sensor_manufacturer IV_MEASURE JörnGroße-Knetter N/A a year ago No tags Selected
66f6c4…2936c7 sensor_manufacturer CV_MEASURE JörnGroße-Knetter N/A a year ago No tags Selected
Stage Tests
sensor_manufacturer
  • CV measurement  (CV_MEASURE)
  • IV measurement  (IV_MEASURE)
WAFER_PROCESSING
  • Visual inspection  (VISUAL_INSPECTION)
  • Sensor Metrology: Sensor bow and thickness  (SENSOR_METROLOGY)
  • IV measurement  (IV_MEASURE)
  • CV measurement  (CV_MEASURE)
QA
  • CV measurement  (CV_MEASURE)
  • IV measurement  (IV_MEASURE)
  • IT measurement  (IT_MEASURE)
  • Inter-pixel capacitance  (INTER-PIXEL_CAPACITANCE)
  • Inter-pixel resistance  (INTER-PIXEL_RESISTANCE)
  • Sensor Metrology: Sensor bow and thickness  (SENSOR_METROLOGY)
POST_IRRAD
  • IV measurement  (IV_MEASURE)
  • CV measurement  (CV_MEASURE)
NOT_USED
BAREMODULEASSEMBLY
BAREMODULERECEPTION
  • IV measurement  (IV_MEASURE)
MODULE/INIT
MODULE/ASSEMBLY
MODULE/WIREBONDING
MODULE/INITIAL_WARM
MODULE/QC_CROSSCHECK
MODULE/INITIAL_COLD
MODULE/PARYLENE_MASKING
MODULE/PARYLENE_COATING
MODULE/PARYLENE_UNMASKING
MODULE/POST_PARYLENE_WARM
MODULE/POST_PARYLENE_COLD
MODULE/WIREBOND_PROTECTION
MODULE/THERMAL_CYCLES
MODULE/LONG_TERM_STABILITY_TEST
MODULE/FINAL_WARM
MODULE/FINAL_COLD
MODULE/FINAL_METROLOGY
MODULE/QC_STATUS
MODULE/UNHAPPY
MODULE/NOTCONSIDEREDINYIELDS
MODULE/GRAVEYARD
MODULE/COMPLETE
MODULE/RECEPTION
MODULE/TAB_CUTTING
LLS/PRE_TC_WARM
LLS/PRE_TC_COLD
LLS/POST_TC_WARM
LLS/POST_TC_COLD
LLS/RECEPTION
OB_LOADED_MODULE_CELL/INIT
OB_LOADED_MODULE_CELL/ASSEMBLY
OB_LOADED_MODULE_CELL/WIREBOND_PROTECTION
OB_LOADED_MODULE_CELL/THERMAL_CYCLES
OB_LOADED_MODULE_CELL/FINAL_WARM
OB_LOADED_MODULE_CELL/FINAL_COLD
OB_LOADED_MODULE_CELL/THERMAL_COLD
OB_LOADED_MODULE_CELL/THERMAL_WARM
OB_LOADED_MODULE_CELL/ENVELOPE_CHECK
OB_LOADED_MODULE_CELL/QC_STATUS
OB_LOADED_MODULE_CELL/UNHAPPY
OB_LOADED_MODULE_CELL/GRAVEYARD
OB_LOADED_MODULE_CELL/COMPLETE
OB_LOADED_MODULE_CELL/RECEPTION
OB_LOADED_MODULE_CELL/TAB_CUTTING
OB_LOADED_MODULE_CELL/PIGTAIL_INSERTION
Back to top page of this component