Top Page > Component List > 20 U PG S3 3303740 > QC Result / BAREMODULERECEPTION / IV_MEASURE
Item | Value |
---|---|
Serial Number | 20 U PG S3 3303740 |
Production DB Component ID | 206a8343ee434fe51c0e1230463ea0eb |
LocalDB Component ID | 66f6bbe213e0b0004328dad7 |
Component Type | sensor_tile |
Super-Component | 20 U PG B4 3200156 |
Sub-Components | No match. |
Flags |
Key | Data |
---|---|
QC Passed | True |
Date | 2025-03-06 08:26:47 PST(-0800) |
component ObjectId | 66f6bbe213e0b0004328dad7 |
Stage | BAREMODULERECEPTION |
Test Type | IV_MEASURE |
Institute ObjectId | |
User Name | AnnaRaquel Petri |
ObjectId of this record | 67c9ccc72717b3491d6a2c3b |
ObjectId of RAW record | None |
Key | Data |
---|---|
ANALYSIS_VERSION | mqat vwebApp SHA:21c6060 |
HUM | 41.77585365853658 |
MEASUREMENT_DATE | 2025-02-27T14:45Z |
TEMP | 20.427073170731706 |
BREAKDOWN_VOLTAGE | -999 |
IV_ARRAY | {'voltage': [0, 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 105, 110, 115, 120, 125, 130, 135, 140, 145, 150, 155, 160, 165, 170, 175, 180, 185, 190, 195, 200], 'current': [0.00011419767456062894, 0.2399550515935967, 0.2723391854951997, 0.2880976173121548, 0.2996008139012635, 0.29713040272371855, 0.30462529446730446, 0.3079363705215597, 0.3140035936824295, 0.3170711288214718, 0.31927098926776826, 0.322782583114938, 0.3235845965115888, 0.3239354256158458, 0.3267286835356516, 0.32713797131839434, 0.32906259162866164, 0.33130756472669665, 0.33393758899180176, 0.3352462314297705, 0.3370509108243376, 0.3388910159277084, 0.34078235783361954, 0.3426693377264597, 0.344067252180281, 0.34592553715269825, 0.3474616686829455, 0.34943177718250057, 0.3502177387562167, 0.35264803482017726, 0.3539198360616569, 0.3553799838277911, 0.3568949793344383, 0.35871605720198524, 0.3603554904457546, 0.36197558832032645, 0.3633136960121523, 0.36499919519528506, 0.36729620431679827, 0.36902608433490736, 0.3710424128405127], 'sigma current': [0.0001580603976404701, 0.001039681900283817, 0.0007717432993626286, 0.0014883075355733688, 0.00047397173192782993, 0.0018907692617027576, 0.000823038278845183, 0.0006199822639936286, 0.0009941177545386129, 0.0010933416139930333, 0.0010603537325922056, 0.001535051454837912, 0.0011132159818891135, 0.0011561919500863353, 0.0006896165636706295, 0.0004472082772291044, 0.0007032632762107438, 0.0017064110806016184, 0.0015650421883202344, 0.0006239309603010725, 0.0009551052756982672, 0.0006983607841860091, 0.0005681080319798371, 0.0006983147594188532, 0.0006600514915940676, 0.0006512155479477514, 0.0014172656551731334, 0.0014565895091693552, 0.0017516115636432889, 0.001126880059475915, 0.0007973732977721278, 0.0008565866398418598, 0.0007115189351739797, 0.0008131946978156904, 0.0004759072836873521, 0.0008820580520703977, 0.0008714189213894495, 0.0010912901640820465, 0.0007302755949335402, 0.000722515042596188, 0.0008807317251391895]} |
LEAK_CURRENT | 0.3388910159277084 |
MAXIMUM_VOLTAGE | 200 |
NO_BREAKDOWN_VOLTAGE_OBSERVED | True |
Test | Local Result | ProdDB Record |
---|---|---|
IV measurement (IV_MEASURE) |
Registered
Jump to the LocalDB Test Record!
|
Registered
Jump to the ITkPD TestRun Page!
|
Test | Local Result | ProdDB Record |
---|---|---|
CV measurement (CV_MEASURE) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
IV measurement (IV_MEASURE) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
Test | Local Result | ProdDB Record |
---|---|---|
CV measurement (CV_MEASURE) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
Inter-pixel capacitance (INTER-PIXEL_CAPACITANCE) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
Inter-pixel resistance (INTER-PIXEL_RESISTANCE) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
IT measurement (IT_MEASURE) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
IV measurement (IV_MEASURE) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
Sensor Metrology: Sensor bow and thickness (SENSOR_METROLOGY) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
Test | Local Result | ProdDB Record |
---|---|---|
CV measurement (CV_MEASURE) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
IV measurement (IV_MEASURE) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
Sensor Metrology: Sensor bow and thickness (SENSOR_METROLOGY) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
Visual inspection (VISUAL_INSPECTION) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
Test | Local Result | ProdDB Record |
---|---|---|
CV measurement (CV_MEASURE) |
Registered
Jump to the LocalDB Test Record!
|
Registered
Jump to the ITkPD TestRun Page!
|
IV measurement (IV_MEASURE) |
Registered
Jump to the LocalDB Test Record!
|
Registered
Jump to the ITkPD TestRun Page!
|
LocalDB Test ID |
Stage |
Test Name |
Inspector |
Date |
QC Registration |
---|---|---|---|---|---|
67c9ccc72717b3491d6a2c3b | BAREMODULERECEPTION | IV_MEASURE | AnnaRaquel Petri | 2025-03-06 08:26:47 PST(-0800) | Selected |
66f6c72413e0b000432952cb | sensor_manufacturer | IV_MEASURE | JörnGroße-Knetter | 2024-09-27 07:54:28 PDT(-0700) | Selected |
66f6c465db6782004337b0ff | sensor_manufacturer | CV_MEASURE | JörnGroße-Knetter | 2024-09-27 07:42:45 PDT(-0700) | Selected |
Stage | Tests |
---|---|
sensor_manufacturer |
|
WAFER_PROCESSING |
|
QA |
|
POST_IRRAD |
|
NOT_USED |
|
BAREMODULEASSEMBLY |
|
BAREMODULERECEPTION |
|
MODULE/INIT |
|
MODULE/ASSEMBLY |
|
MODULE/WIREBONDING |
|
MODULE/INITIAL_WARM |
|
MODULE/QC_CROSSCHECK |
|
MODULE/INITIAL_COLD |
|
MODULE/PARYLENE_MASKING |
|
MODULE/PARYLENE_COATING |
|
MODULE/PARYLENE_UNMASKING |
|
MODULE/POST_PARYLENE_WARM |
|
MODULE/POST_PARYLENE_COLD |
|
MODULE/WIREBOND_PROTECTION |
|
MODULE/THERMAL_CYCLES |
|
MODULE/LONG_TERM_STABILITY_TEST |
|
MODULE/FINAL_WARM |
|
MODULE/FINAL_COLD |
|
MODULE/FINAL_METROLOGY |
|
MODULE/QC_STATUS |
|
MODULE/UNHAPPY |
|
MODULE/NOTCONSIDEREDINYIELDS |
|
MODULE/COMPLETE |
|
MODULE/RECEPTION |
|
MODULE/TAB_CUTTING |
|
OB_LOADED_MODULE_CELL/INIT |
|
OB_LOADED_MODULE_CELL/ASSEMBLY |
|
OB_LOADED_MODULE_CELL/THERMAL_CYCLES |
|
OB_LOADED_MODULE_CELL/FINAL_WARM |
|
OB_LOADED_MODULE_CELL/FINAL_COLD |
|
OB_LOADED_MODULE_CELL/THERMAL_COLD |
|
OB_LOADED_MODULE_CELL/THERMAL_WARM |
|
OB_LOADED_MODULE_CELL/ENVELOPE_CHECK |
|
OB_LOADED_MODULE_CELL/QC_STATUS |
|
OB_LOADED_MODULE_CELL/UNHAPPY |
|
OB_LOADED_MODULE_CELL/COMPLETE |
|
OB_LOADED_MODULE_CELL/RECEPTION |
|
OB_LOADED_MODULE_CELL/TAB_CUTTING |
|
OB_LOADED_MODULE_CELL/PIGTAIL_INSERTION |
|