Top Page > Component List > 20UPGS33303693 > QC Result / BAREMODULERECEPTION / IV_MEASURE


20UPGS33303693
Outer-Quad-Sensor
  ITkPD Component Page Jump to ITkPD component page

Component Information

Item Value
Serial Number 20UPGS33303693
Production DB Component ID 3be81114090b076a2c47ef2ab62fe119
LocalDB Component ID 66f6ba3adb67820043374874
Component Type sensor_tile
Super-Component 20UPGB43200023
Sub-Components No match.
Flags

Properties

Item Data Type Value
Main Vendor integer 3
Sensor Type or Test Structure integer 3
Version of component string production
Scratch id (to be used if not the same as agreed manufacturer ID) string 7022
Alternative Identifier string V4-2-007022-3-002
Original Manufacturer ID string Q2
Breakdown Voltage (-999 if no breakdown occurred) float -999
Depletion Voltage (V) float 59.54

Comments


Test: IV_MEASURE QC Passed

(Stage: BAREMODULERECEPTION)


Basic View Only: custom view for this TestRun is not prepared.

Metadata

Key Data
QC Passed True
Date 2024-10-17 07:00:26 PDT(-0700)
component ObjectId 66f6ba3adb67820043374874
Stage BAREMODULERECEPTION
Test Type IV_MEASURE
Institute ObjectId
User Name AbdoulayeNDIAYE
ObjectId of this record 6711187a07e8e500432d8838
ObjectId of RAW record None

Results

Key Data
ANALYSIS_VERSION mqat vwebApp SHA:ca10f11
HUM 12.47442
TEMP 20.029756097560977
BREAKDOWN_VOLTAGE -999
IV_ARRAY {'voltage': [0, 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 105, 110, 115, 120, 125, 130, 135, 140, 145, 150, 155, 160, 165, 170, 175, 180, 185, 190, 195, 200], 'current': [0.000487882, 0.23863600000000001, 0.270177, 0.289453, 0.301496, 0.312503, 0.320847, 0.330055, 0.338572, 0.347606, 0.357763, 0.368268, 0.379703, 0.39274200000000004, 0.409369, 0.42982200000000004, 0.45355500000000004, 0.480554, 0.510575, 0.54499, 0.583194, 0.62484, 0.6714870000000001, 0.722216, 0.776466, 0.83569, 0.899255, 0.9676760000000001, 1.03942, 1.11557, 1.19595, 1.28193, 1.37151, 1.4663400000000002, 1.56572, 1.6697300000000002, 1.77943, 1.8932900000000001, 2.0123300000000004, 2.13688, 2.2650200000000003], 'sigma current': [0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0], 'temperature': [20.03, 20.02, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03, 20.03], 'humidity': [14.54297, 14.35824, 14.29196, 14.16773, 14.04433, 13.92178, 13.86081, 13.67917, 13.61903, 12.79855, 12.85585, 12.79855, 12.74146, 12.79855, 12.74146, 12.74146, 12.74146, 12.68456, 12.68456, 12.62786, 12.57137, 12.51506, 12.40305, 12.34734, 12.29182, 12.2365, 12.18138, 11.48224, 11.48224, 11.48224, 11.42979, 11.42979, 11.37753, 11.32546, 11.32546, 11.27357, 11.22187, 11.17035, 11.11902, 11.06788, 11.01692]}
LEAK_CURRENT 0.62484
MAXIMUM_VOLTAGE 200
NO_BREAKDOWN_VOLTAGE_OBSERVED True

ProductionDB Record

{}

Current Stage: Ranking of the module

No tests are allocated for this stage.


Past QC Stages and Results

  Stage: Final flatness measurement (MODULE/FINAL_METROLOGY) Complete

No tests are allocated for this stage.

  Stage: Final Cold (MODULE/FINAL_COLD) Complete

No tests are allocated for this stage.

  Stage: Final Warm (MODULE/FINAL_WARM) Complete

No tests are allocated for this stage.

  Stage: Long Term Stability Test (MODULE/LONG_TERM_STABILITY_TEST) Complete

No tests are allocated for this stage.

  Stage: Thermal Cycles (MODULE/THERMAL_CYCLES) Complete

No tests are allocated for this stage.

  Stage: Wirebond Protection (alt) (MODULE/WIREBOND_PROTECTION) Complete

No tests are allocated for this stage.

  Stage: Post-Parylene Cold (MODULE/POST_PARYLENE_COLD) Complete

No tests are allocated for this stage.

  Stage: Post-Parylene Warm (MODULE/POST_PARYLENE_WARM) Complete

No tests are allocated for this stage.

  Stage: Parylene Unmasking (MODULE/PARYLENE_UNMASKING) Complete

No tests are allocated for this stage.

  Stage: Parylene Coating (MODULE/PARYLENE_COATING) Complete

No tests are allocated for this stage.

  Stage: Parylene Masking (MODULE/PARYLENE_MASKING) Complete

No tests are allocated for this stage.

  Stage: Initial Cold (MODULE/INITIAL_COLD) Complete

No tests are allocated for this stage.

  Stage: QC cross-check (module swapping) (MODULE/QC_CROSSCHECK) Alternative

No tests are allocated for this stage.

  Stage: Initial Warm (MODULE/INITIAL_WARM) Complete

No tests are allocated for this stage.

  Stage: Wire Bonding (MODULE/WIREBONDING) Complete

No tests are allocated for this stage.

  Stage: Bare module to module PCB assembly (MODULE/ASSEMBLY) Complete

No tests are allocated for this stage.

  Stage: Initial state to associate flex to bare module (MODULE/INIT) Locally Signed Off

No tests are allocated for this stage.

  Stage: Bare module reception at ITk institute (BAREMODULERECEPTION) Complete

Test Local Result ProdDB Record
IV measurement
(IV_MEASURE)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!

  Stage: Bare Module Assembly (BAREMODULEASSEMBLY) Locally Signed Off

No tests are allocated for this stage.

  Stage: Not to be used for detector (NOT_USED) Alternative

No tests are allocated for this stage.

  Stage: Post Irradiation (POST_IRRAD) Alternative

Test Local Result ProdDB Record
CV measurement
(CV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
IV measurement
(IV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.

  Stage: QA at Institutes (QA) Alternative

Test Local Result ProdDB Record
CV measurement
(CV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Inter-pixel capacitance
(INTER-PIXEL_CAPACITANCE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Inter-pixel resistance
(INTER-PIXEL_RESISTANCE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
IT measurement
(IT_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
IV measurement
(IV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Sensor Metrology: Sensor bow and thickness
(SENSOR_METROLOGY)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.

  Stage: Wafer Processing (dicing, UBM, flip-chip) (WAFER_PROCESSING) Locally Signed Off

Test Local Result ProdDB Record
CV measurement
(CV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
IV measurement
(IV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Sensor Metrology: Sensor bow and thickness
(SENSOR_METROLOGY)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Visual inspection
(VISUAL_INSPECTION)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.

  Stage: Sensor Manufacturer (sensor_manufacturer) Complete

Test Local Result ProdDB Record
CV measurement
(CV_MEASURE)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
IV measurement
(IV_MEASURE)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
LocalDB Test ID Stage Test Name Inspector Date QC Registration
6711187a07e8e500432d8838 BAREMODULERECEPTION IV_MEASURE AbdoulayeNDIAYE 2024-10-17 07:00:26 PDT(-0700) Selected
66f6c71313e0b00043295115 sensor_manufacturer IV_MEASURE JörnGroße-Knetter 2024-09-27 07:54:11 PDT(-0700) Selected
66f6c45213e0b0004329342f sensor_manufacturer CV_MEASURE JörnGroße-Knetter 2024-09-27 07:42:26 PDT(-0700) Selected
Stage Tests
sensor_manufacturer
  • CV measurement  (CV_MEASURE)
  • IV measurement  (IV_MEASURE)
WAFER_PROCESSING
  • Visual inspection  (VISUAL_INSPECTION)
  • Sensor Metrology: Sensor bow and thickness  (SENSOR_METROLOGY)
  • IV measurement  (IV_MEASURE)
  • CV measurement  (CV_MEASURE)
QA
  • CV measurement  (CV_MEASURE)
  • IV measurement  (IV_MEASURE)
  • IT measurement  (IT_MEASURE)
  • Inter-pixel capacitance  (INTER-PIXEL_CAPACITANCE)
  • Inter-pixel resistance  (INTER-PIXEL_RESISTANCE)
  • Sensor Metrology: Sensor bow and thickness  (SENSOR_METROLOGY)
POST_IRRAD
  • IV measurement  (IV_MEASURE)
  • CV measurement  (CV_MEASURE)
NOT_USED
BAREMODULEASSEMBLY
BAREMODULERECEPTION
  • IV measurement  (IV_MEASURE)
MODULE/INIT
MODULE/ASSEMBLY
MODULE/WIREBONDING
MODULE/INITIAL_WARM
MODULE/QC_CROSSCHECK
MODULE/INITIAL_COLD
MODULE/PARYLENE_MASKING
MODULE/PARYLENE_COATING
MODULE/PARYLENE_UNMASKING
MODULE/POST_PARYLENE_WARM
MODULE/POST_PARYLENE_COLD
MODULE/WIREBOND_PROTECTION
MODULE/THERMAL_CYCLES
MODULE/LONG_TERM_STABILITY_TEST
MODULE/FINAL_WARM
MODULE/FINAL_COLD
MODULE/FINAL_METROLOGY
MODULE/QC_STATUS
MODULE/UNHAPPY
MODULE/NOTCONSIDEREDINYIELDS
MODULE/COMPLETE
MODULE/RECEPTION
MODULE/TAB_CUTTING
OB_LOADED_MODULE_CELL/INIT
OB_LOADED_MODULE_CELL/ASSEMBLY
OB_LOADED_MODULE_CELL/THERMAL_CYCLES
OB_LOADED_MODULE_CELL/FINAL_WARM
OB_LOADED_MODULE_CELL/FINAL_COLD
OB_LOADED_MODULE_CELL/THERMAL_COLD
OB_LOADED_MODULE_CELL/THERMAL_WARM
OB_LOADED_MODULE_CELL/ENVELOPE_CHECK
OB_LOADED_MODULE_CELL/QC_STATUS
OB_LOADED_MODULE_CELL/UNHAPPY
OB_LOADED_MODULE_CELL/COMPLETE
OB_LOADED_MODULE_CELL/RECEPTION
OB_LOADED_MODULE_CELL/TAB_CUTTING
OB_LOADED_MODULE_CELL/PIGTAIL_INSERTION
Back to top page of this component