Top Page > Component List > 20UPGS33303678 > QC Result / BAREMODULERECEPTION / IV_MEASURE


20UPGS33303678
Outer-Quad-Sensor
  ITkPD Component Page Jump to ITkPD component page

Component Information

Item Value
Serial Number 20UPGS33303678
Production DB Component ID 2f0c55b955fa052e79e03d653978443a
LocalDB Component ID 66f6b9b1db6782004337468d
Component Type sensor_tile
Super-Component 20UPGB43200085
Sub-Components No match.
Flags

Properties

Item Data Type Value
Main Vendor integer 3
Sensor Type or Test Structure integer 3
Version of component string production
Scratch id (to be used if not the same as agreed manufacturer ID) string 7019
Alternative Identifier string V4-2-007019-3-005
Original Manufacturer ID string Q5
Breakdown Voltage (-999 if no breakdown occurred) float -999
Depletion Voltage (V) float 59.12

Comments


Test: IV_MEASURE QC Passed

(Stage: BAREMODULERECEPTION)


Basic View Only: custom view for this TestRun is not prepared.

Metadata

Key Data
QC Passed True
Date 2025-01-22 01:12:34 PST(-0800)
component ObjectId 66f6b9b1db6782004337468d
Stage BAREMODULERECEPTION
Test Type IV_MEASURE
Institute ObjectId
User Name MarioJose
ObjectId of this record 6790b6829ad8e8353834beb3
ObjectId of RAW record None

Results

Key Data
ANALYSIS_VERSION mqat vwebApp SHA:53c288c
HUM 49
TEMP 23
BREAKDOWN_VOLTAGE -999
IV_ARRAY {'voltage': [0, 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 105, 110, 115, 120, 125, 130, 135, 140, 145, 150, 155, 160, 165, 170, 175, 180, 185, 190, 195, 200], 'current': [0.005630775, 0.6000686, 0.6918066, 0.746979, 0.7864501, 0.8160326, 0.8600786, 0.8756689, 0.8982075, 0.9134918000000001, 0.9251885000000001, 0.9435884999999999, 0.958623, 0.9733199, 0.9884132999999999, 1.003396, 1.020356, 1.034306, 1.041397, 1.05895, 1.073992, 1.091484, 1.1093, 1.127077, 1.141908, 1.159343, 1.18056, 1.199918, 1.214378, 1.24077, 1.260976, 1.283351, 1.310749, 1.336344, 1.358769, 1.392144, 1.418166, 1.448988, 1.484905, 1.51421, 1.53779], 'sigma current': [0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0, 0], 'temperature': [23, 23, 23, 23, 23, 23, 23, 23, 23, 23, 23, 23, 23, 23, 23, 23, 23, 23, 23, 23, 23, 23, 23, 23, 23, 23, 23, 23, 23, 23, 23, 23, 23, 23, 23, 23, 23, 23, 23, 23, 23], 'humidity': [49, 49, 49, 49, 49, 49, 49, 49, 49, 49, 49, 49, 49, 49, 49, 49, 49, 49, 49, 49, 49, 49, 49, 49, 49, 49, 49, 49, 49, 49, 49, 49, 49, 49, 49, 49, 49, 49, 49, 49, 49]}
LEAK_CURRENT 1.091484
MAXIMUM_VOLTAGE 200
NO_BREAKDOWN_VOLTAGE_OBSERVED True

ProductionDB Record

{}

Current Stage: Initial state to associate flex to bare module

No tests are allocated for this stage.


Past QC Stages and Results

  Stage: Bare module reception at ITk institute (BAREMODULERECEPTION) Complete

Test Local Result ProdDB Record
IV measurement
(IV_MEASURE)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!

  Stage: Bare Module Assembly (BAREMODULEASSEMBLY) Locally Signed Off

No tests are allocated for this stage.

  Stage: Not to be used for detector (NOT_USED) Alternative

No tests are allocated for this stage.

  Stage: Post Irradiation (POST_IRRAD) Alternative

Test Local Result ProdDB Record
CV measurement
(CV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
IV measurement
(IV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.

  Stage: QA at Institutes (QA) Alternative

Test Local Result ProdDB Record
CV measurement
(CV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Inter-pixel capacitance
(INTER-PIXEL_CAPACITANCE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Inter-pixel resistance
(INTER-PIXEL_RESISTANCE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
IT measurement
(IT_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
IV measurement
(IV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Sensor Metrology: Sensor bow and thickness
(SENSOR_METROLOGY)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.

  Stage: Wafer Processing (dicing, UBM, flip-chip) (WAFER_PROCESSING) Locally Signed Off

Test Local Result ProdDB Record
CV measurement
(CV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
IV measurement
(IV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Sensor Metrology: Sensor bow and thickness
(SENSOR_METROLOGY)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Visual inspection
(VISUAL_INSPECTION)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.

  Stage: Sensor Manufacturer (sensor_manufacturer) Complete

Test Local Result ProdDB Record
CV measurement
(CV_MEASURE)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
IV measurement
(IV_MEASURE)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
LocalDB Test ID Stage Test Name Inspector Date QC Registration
6790b6829ad8e8353834beb3 BAREMODULERECEPTION IV_MEASURE MarioJose 2025-01-22 01:12:34 PST(-0800) Selected
66f6c70e13e0b00043295083 sensor_manufacturer IV_MEASURE JörnGroße-Knetter 2024-09-27 07:54:06 PDT(-0700) Selected
66f6c44b13e0b00043293396 sensor_manufacturer CV_MEASURE JörnGroße-Knetter 2024-09-27 07:42:19 PDT(-0700) Selected
Stage Tests
sensor_manufacturer
  • CV measurement  (CV_MEASURE)
  • IV measurement  (IV_MEASURE)
WAFER_PROCESSING
  • Visual inspection  (VISUAL_INSPECTION)
  • Sensor Metrology: Sensor bow and thickness  (SENSOR_METROLOGY)
  • IV measurement  (IV_MEASURE)
  • CV measurement  (CV_MEASURE)
QA
  • CV measurement  (CV_MEASURE)
  • IV measurement  (IV_MEASURE)
  • IT measurement  (IT_MEASURE)
  • Inter-pixel capacitance  (INTER-PIXEL_CAPACITANCE)
  • Inter-pixel resistance  (INTER-PIXEL_RESISTANCE)
  • Sensor Metrology: Sensor bow and thickness  (SENSOR_METROLOGY)
POST_IRRAD
  • IV measurement  (IV_MEASURE)
  • CV measurement  (CV_MEASURE)
NOT_USED
BAREMODULEASSEMBLY
BAREMODULERECEPTION
  • IV measurement  (IV_MEASURE)
MODULE/INIT
MODULE/ASSEMBLY
MODULE/WIREBONDING
MODULE/INITIAL_WARM
MODULE/QC_CROSSCHECK
MODULE/INITIAL_COLD
MODULE/PARYLENE_MASKING
MODULE/PARYLENE_COATING
MODULE/PARYLENE_UNMASKING
MODULE/POST_PARYLENE_WARM
MODULE/POST_PARYLENE_COLD
MODULE/WIREBOND_PROTECTION
MODULE/THERMAL_CYCLES
MODULE/LONG_TERM_STABILITY_TEST
MODULE/FINAL_WARM
MODULE/FINAL_COLD
MODULE/FINAL_METROLOGY
MODULE/QC_STATUS
MODULE/UNHAPPY
MODULE/NOTCONSIDEREDINYIELDS
MODULE/COMPLETE
MODULE/RECEPTION
MODULE/TAB_CUTTING
OB_LOADED_MODULE_CELL/INIT
OB_LOADED_MODULE_CELL/ASSEMBLY
OB_LOADED_MODULE_CELL/THERMAL_CYCLES
OB_LOADED_MODULE_CELL/FINAL_WARM
OB_LOADED_MODULE_CELL/FINAL_COLD
OB_LOADED_MODULE_CELL/THERMAL_COLD
OB_LOADED_MODULE_CELL/THERMAL_WARM
OB_LOADED_MODULE_CELL/ENVELOPE_CHECK
OB_LOADED_MODULE_CELL/QC_STATUS
OB_LOADED_MODULE_CELL/UNHAPPY
OB_LOADED_MODULE_CELL/COMPLETE
OB_LOADED_MODULE_CELL/RECEPTION
OB_LOADED_MODULE_CELL/TAB_CUTTING
OB_LOADED_MODULE_CELL/PIGTAIL_INSERTION
Back to top page of this component