20UPIMS2102142

MODULE/PARYLENE_MASKING

Component Information

Serial Number 20UPIMS2102142
ProdDB ID  e7bb6e…b49e88
LocalDB ID 6634e3bcdda7600035dfd11e
Component Type MODULE
Parents No match.
Children 20UPGB12100055 Bare Module 20UPGB12100054 Bare Module 20UPGFC0097899 FE Chip 20UPGB12100050 Bare Module 20UPGFC0097962 FE Chip 20UPIPT3272142 PCB 20UPGFC0097959 FE Chip
Flags
Distribution of chips on wafer

 Properties

Item Value
PCB-Bare Orientation isNormal False
FE chip version 2
Wirebond protection roof presence False
IREF Trim Bit FE1 deleted 9
IREF Trim Bit FE2 deleted 13
IREF Trim Bit FE3 deleted 9
IREF Trim Bit FE4 deleted None
Alternative ID None

 Comments


Test: TRIPLET_METROLOGY QC Passed

(Stage: MODULE/ASSEMBLY)


Basic View Only: custom view for this TestRun is not prepared.

Metadata

Key Data
QC Passed True
Date a year ago
component ObjectId 6634e3bcdda7600035dfd11e
Stage MODULE/ASSEMBLY
Test Type TRIPLET_METROLOGY
Institute ObjectId
User Name PabloFernández Martínez
ObjectId of this record 6667064c61ecee00340bf9e6
ObjectId of RAW record None
Tags No tags

Results

Key Data
CUTVERSION 0
AX_TO_FLEX_IN_FE_LOCSYST 0.2751999999999981
AY_TO_FLEX_IN_FE_LOCSYST 2.768000000000001
BX_TO_FLEX_IN_FE_LOCSYST 0.2377999999999929
BY_TO_FLEX_IN_FE_LOCSYST 2.773700000000005
CX_TO_FLEX_IN_FE_LOCSYST 0.2582000000000022
CY_TO_FLEX_IN_FE_LOCSYST 2.785699999999992
DX_TO_FLEX_IN_FE_LOCSYST 0.2656999999999954
DY_TO_FLEX_IN_FE_LOCSYST 2.785199999999989
EX_TO_FLEX_IN_FE_LOCSYST 0.29749999999999943
EY_TO_FLEX_IN_FE_LOCSYST 2.8063999999999965
FLEXFM_TO_LEFTSENSOREDGE 0.23739999999999384
FLEXFM_TO_RIGHTSENSOREDGE 0.22649999999998727
FX_TO_FLEX_IN_FE_LOCSYST 0.22309999999998809
FY_TO_FLEX_IN_FE_LOCSYST 2.799700000000002
MAX_MODULE_LENGTH 61.3293
THICKNESS_CONNECTOR 0
THICKNESS_HV_CAP [2.1915, 2.1915]
THICKNESS_SMD [1.0193, 1.019]

ProductionDB Record

{}

 Current Stage: Parylene Masking

Test Type Local Result
Visual Inspection
(VISUAL_INSPECTION)
No TestRun!

 Candidate TestRuns of this Stage

LDB ID TestRun Code QC Passed Inspector Measurement Date Analysis Date Analysis Version Tags QC Registration
666706…0bf9e6 TRIPLET_METROLOGY Pass PabloFernández Martínez N/A a year ago No tags Selected

Past QC Stages and Results

Initial Cold (MODULE/INITIAL_COLD)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
No result N/A

QC cross-check (module swapping) (MODULE/QC_CROSSCHECK)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A

Initial Warm (MODULE/INITIAL_WARM)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
No result N/A

Wire Bonding (MODULE/WIREBONDING)

Test Local Result ProdDB Record
Visual Inspection
(VISUAL_INSPECTION)
No result N/A
Wirebond pull test
(WIREBOND_PULL_TEST)
No result N/A
Wirebonding Information
(WIREBONDING)
No result N/A

Bare module to module PCB assembly (MODULE/ASSEMBLY)

Test Local Result ProdDB Record
Flatness
(FLATNESS)
No result N/A
Glue Information Module+Flex Attach
(GLUE_MODULE_FLEX_ATTACH)
No result N/A
Mass Measurement
(MASS_MEASUREMENT)
No result N/A
Quad Module Metrology
(QUAD_MODULE_METROLOGY)
No result N/A
Triplet Module Metrology
(TRIPLET_METROLOGY)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Initial state to associate flex to bare module (MODULE/INIT)

LocalDB Test ID Stage Test Name Inspector Measurement Date Analysis Date Tags QC Registration
666970…e60665 MODULE/INITIAL_COLD E_SUMMARY JuanIgnacioCarlotto N/A a year ago No tags Selected
66696c…e603bb MODULE/INITIAL_WARM E_SUMMARY JuanIgnacioCarlotto N/A a year ago No tags Selected
666706…0bf9e6 MODULE/ASSEMBLY TRIPLET_METROLOGY PabloFernández Martínez N/A a year ago No tags Selected
Stage Tests
MODULE/INIT
MODULE/ASSEMBLY
  • Mass Measurement  (MASS_MEASUREMENT)
  • Glue Information Module+Flex Attach  (GLUE_MODULE_FLEX_ATTACH)
  • Triplet Module Metrology  (TRIPLET_METROLOGY)
  • Visual Inspection  (VISUAL_INSPECTION)
  • Flatness  (FLATNESS)
  • Quad Module Metrology  (QUAD_MODULE_METROLOGY)
MODULE/WIREBONDING
  • Wirebonding Information  (WIREBONDING)
  • Wirebond pull test  (WIREBOND_PULL_TEST)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/INITIAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/QC_CROSSCHECK
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/INITIAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/PARYLENE_MASKING
  • Visual Inspection  (VISUAL_INSPECTION)
  • Parylene (de-)masking  (DE_MASKING)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/PARYLENE_COATING
  • Parylene Properties  (PARYLENE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/PARYLENE_UNMASKING
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Parylene (de-)masking  (DE_MASKING)
MODULE/WIREBOND_PROTECTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Wire bonding protection roof envelope  (WP_ENVELOPE)
  • Mass Measurement  (MASS_MEASUREMENT)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
MODULE/POST_PARYLENE_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/POST_PARYLENE_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/THERMAL_CYCLES
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Thermal Cycling  (THERMAL_CYCLING)
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
MODULE/LONG_TERM_STABILITY_TEST
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Longterm stability DCS  (LONG_TERM_STABILITY_DCS)
MODULE/FINAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/FINAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/FINAL_METROLOGY
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/QC_STATUS
  • Module ranking  (RANKING)
MODULE/UNHAPPY
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/NOTCONSIDEREDINYIELDS
MODULE/GRAVEYARD
MODULE/COMPLETE
MODULE/RECEPTION
  • Visual Inspection  (VISUAL_INSPECTION)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/TAB_CUTTING
  • Mass Measurement  (MASS_MEASUREMENT)
  • Module PCB Tab Cutting Information  (CUTTER_PCB_TAB)
  • Visual Inspection  (VISUAL_INSPECTION)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
LLS/PRE_TC_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/PRE_TC_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/POST_TC_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/POST_TC_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/RECEPTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
OB_LOADED_MODULE_CELL/INIT
OB_LOADED_MODULE_CELL/ASSEMBLY
OB_LOADED_MODULE_CELL/THERMAL_CYCLES
OB_LOADED_MODULE_CELL/FINAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/FINAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/THERMAL_COLD
  • Thermal Measure  (THERMAL_PERFORMANCE)
OB_LOADED_MODULE_CELL/THERMAL_WARM
  • Thermal Measure  (THERMAL_PERFORMANCE)
OB_LOADED_MODULE_CELL/ENVELOPE_CHECK
OB_LOADED_MODULE_CELL/QC_STATUS
OB_LOADED_MODULE_CELL/UNHAPPY
OB_LOADED_MODULE_CELL/COMPLETE
OB_LOADED_MODULE_CELL/RECEPTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/TAB_CUTTING
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Module PCB Tab Cutting Information  (CUTTER_PCB_TAB)
OB_LOADED_MODULE_CELL/PIGTAIL_INSERTION
Back to top page of this component