Top Page > Component List > 20UPGM22110358 > QC Result / MODULE/THERMAL_CYCLES / THERMAL_CYCLING


20UPGM22110358
Outer-Quad-Module/ITkPix_v1.1
  ITkPD Component Page Jump to ITkPD component page

Component Information

Item Value
Serial Number 20UPGM22110358
Production DB Component ID a483e1f9a8ad342b6a4609ba206c7954
LocalDB Component ID 6630e99101a6f30034901189
Component Type module
Super-Component No match.
Sub-Components •  20UPGB42000067   Bare Module
•  20UPGPQ1110358   PCB
•  20UPGFC0084935   FE Chip
•  20UPGFC0084938   FE Chip
•  20UPGFC0084936   FE Chip
•  20UPGFC0084933   FE Chip
Flags

Properties

Item Data Type Value
PCB-Bare Orientation isNormal boolean False
FE chip version codeTable 2
Wirebond protection roof presence boolean False
Alternative ID string None
Rank codeTable None

Comments


Test: THERMAL_CYCLING QC Passed

(Stage: MODULE/THERMAL_CYCLES)


Result of This Test

Scan

Key Data
component id 6630e99101a6f30034901189
current Stage MODULE/THERMAL_CYCLES
test Type THERMAL_CYCLING
institute 64657cef8d79bac1f3f00550
user name Md ArifAbdullaSamy

Key Data

Results

Key Data
properties {'CYCLING_SPEED': 35, 'LOCATION': 'Glasgow', 'MACHINE': 'cold box', 'MAX_TEMP': 40, 'MAX_TEMP_EXT': 19.991, 'MEASUREMENT_DATE': '2024-12-12T11:12:00.000+00:00', 'MIN_TEMP': -45, 'MIN_TEMP_EXT': -55, 'NUM_CYCLES': 10, 'NUM_CYCLES_EXT': 1}

RAW Results Record

Download RAW
_id675b411b9e4f640bdf7d4d4f
raw
serialNumbertestTyperesultsstagecomponentdbVersionaddressusersys
20UPGM22110358THERMAL_CYCLING
property
MACHINEcold box
MIN_TEMP-45.0
MAX_TEMP40.0
NUM_CYCLES10
CYCLING_SPEED35.0
MIN_TEMP_EXT-55.0
MAX_TEMP_EXT19.991
NUM_CYCLES_EXT1
MEASUREMENT_DATENone
LOCATIONGlasgow
comment
Measurements
Metadata
LocalDB version2.2.36-rc3
InstitutionGL
ModuleSN20UPGM22110358
TimeStart1734001920
TimeEnd1734034320
MODULE/THERMAL_CYCLES6630e99101a6f300349011891.0164657cef8d79bac1f3f00550rd53a
mts2024-12-12 20:01:31.308000
cts2024-12-12 20:01:31.308000
rev0
rawHash5f4c84da992e0b4a79553b15a452092f
stageMODULE/THERMAL_CYCLES

ProductionDB Record

id675b6972c71e24b7eb7d853a
stateready
stateTs2024-12-12T22:53:38.867Z
stateUserIdentity8665-7663-1
date2024-12-12T20:01:00.000Z
testType
id5ce2a91d91f5f40009847d0f
codeTHERMAL_CYCLING
nameThermal Cycling
stateactive
institution
id59d60ee4ed67730005160cd9
codeGL
nameGlasgow University
user
id6086c45fe87a6a000aa959a8
userIdentity8665-7663-1
firstNameMd Arif
middleNameAbdulla
lastNameSamy
runNumber675b411c9e4f640bdf7d4d50
passedTrue
problemsFalse
properties
  • codeCYCLING_SPEED
    nameThermal Cycling Speed
    dataTypefloat
    valueTypesingle
    requiredFalse
    value35
  • codeLOCATION
    nameLocation
    dataTypestring
    valueTypeNone
    requiredFalse
    valueGlasgow
    rangeMinNone
    rangeMaxNone
  • codeMACHINE
    nameMachine
    dataTypestring
    valueTypesingle
    requiredFalse
    valuecold box
  • codeMAX_TEMP
    nameMaximum Temperature
    dataTypefloat
    valueTypesingle
    requiredFalse
    value40
    rangeMin-100
    rangeMax100
  • codeMAX_TEMP_EXT
    nameMaximum Temperature Extended cycle range
    dataTypefloat
    valueTypesingle
    requiredFalse
    value19.991
    rangeMin-100
    rangeMax100
  • codeMEASUREMENT_DATE
    nameDate measurement performed
    dataTypedatetime
    valueTypeNone
    requiredFalse
    value2024-12-12T11:12:00.000+00:00
    rangeMinNone
    rangeMaxNone
  • codeMIN_TEMP
    nameMinimum Temperature
    dataTypefloat
    valueTypesingle
    requiredFalse
    value-45
    rangeMin-100
    rangeMax100
  • codeMIN_TEMP_EXT
    nameMinimum Temperature Extended cycle range
    dataTypefloat
    valueTypesingle
    requiredFalse
    value-55
    rangeMin-100
    rangeMax100
  • codeNUM_CYCLES
    nameNumber of Cycles
    dataTypeinteger
    valueTypesingle
    requiredFalse
    value10
    rangeMin0
    rangeMax1000
  • codeNUM_CYCLES_EXT
    nameNumber of Cycles Extended cycle Range
    dataTypeinteger
    valueTypesingle
    requiredFalse
    value1
    rangeMin0
    rangeMax1000
results
cts2024-12-12T22:53:38.867Z
sys
cts2024-12-12T22:53:38.867Z
mts2024-12-12T22:53:39.807Z
rev1
defects
commentsNone
attachments
codedateTimetitledescriptioncontentTypetypebinaryStoreg02filenameuser
7d9772194f9587e00d7e5f2d6bb343e62024-12-12T22:53:39.198ZRAWRAWapplication/jsonfileTrue20UPGM22110358_MODULE__THERMAL_CYCLES_THERMAL_CYCLING_675b6972c71e24b7eb7d853a_675b411b9e4f640bdf7d4d4f.json
id6086c45fe87a6a000aa959a8
userIdentity8665-7663-1
firstNameMd Arif
middleNameAbdulla
lastNameSamy
components
idcodestatestateTsstateUserIdentitydummycompletedcompletedTscompletedUserIdentitytrashedtrashedTstrashedUserIdentityserialNumberalternativeIdentifierprojectsubprojectcomponentTypetypepropertiestestedAtStageinstitution
6630e99101a6f30034901189a483e1f9a8ad342b6a4609ba206c7954ready2024-04-30T12:52:33.420Z24-7185-1FalseFalseNoneNoneFalseNoneNone20UPGM22110358None
codeP
namePixels
codePG
namePixel general
codeMODULE
nameModule
codeOUTER_SYSTEM_QUAD_MODULE
nameOuter system quad module
  • codeORIENTATION
    namePCB-Bare Orientation isNormal
    dataTypeboolean
    requiredTrue
    defaultFalse
    valueFalse
  • codeFECHIP_VERSION
    nameFE chip version
    dataTypecodeTable
    requiredTrue
    defaultFalse
    valueITkpix_v1.1
    codeTable
    codevalue
    0RD53A
    1ITkpix_v1
    2ITkpix_v1.1
    3ITkpix_v2
    9No FE chip
  • codeROOF
    nameWirebond protection roof presence
    dataTypeboolean
    requiredFalse
    defaultFalse
    valueFalse
  • codeIREFTRIM_FE1
    nameIREFTRIM_FE1
    valueNone
  • codeIREFTRIM_FE2
    nameIREFTRIM_FE2
    valueNone
  • codeIREFTRIM_FE3
    nameIREFTRIM_FE3
    valueNone
  • codeIREFTRIM_FE4
    nameIREFTRIM_FE4
    valueNone
codeMODULE/THERMAL_CYCLES
nameThermal Cycles
order12
initialFalse
finalFalse
codeGL
nameGlasgow University

Current Stage: Ranking of the module

Test Type Local Result
Module ranking
(RANKING)
No TestRun! TestRun is missing in LocalDB.

Candidate TestRuns of this Stage

LocalDB Object ID TestRun Code QC Passed Inspector Date Analysis Version QC Registration
675b40069e4f640bdf7d4d4d IV_MEASURE Passed Md ArifAbdullaSamy 2024-12-12 14:53:43 PST(-0800) 2.2.9 Selected
675b411c9e4f640bdf7d4d50 THERMAL_CYCLING Passed Md ArifAbdullaSamy 2024-12-12 14:53:39 PST(-0800) Selected
675b690f9e4f640bdf7d4f31 E_SUMMARY Failed Md ArifAbdullaSamy 2024-12-12 14:53:37 PST(-0800) 2.2.36-rc3 Selected

Past QC Stages and Results

  Stage: Final flatness measurement (MODULE/FINAL_METROLOGY) Complete

Test Local Result ProdDB Record
Flatness
(FLATNESS)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.

  Stage: Final Cold (MODULE/FINAL_COLD) Complete

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
IV measurement
(IV_MEASURE)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
Visual Inspection
(VISUAL_INSPECTION)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.

  Stage: Final Warm (MODULE/FINAL_WARM) Complete

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
IV measurement
(IV_MEASURE)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
Visual Inspection
(VISUAL_INSPECTION)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.

  Stage: Long Term Stability Test (MODULE/LONG_TERM_STABILITY_TEST) Complete

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
IV measurement
(IV_MEASURE)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
Longterm stability DCS
(LONG_TERM_STABILITY_DCS)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!

  Stage: Thermal Cycles (MODULE/THERMAL_CYCLES) Complete

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
Flatness
(FLATNESS)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
IV measurement
(IV_MEASURE)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
Thermal Cycling
(THERMAL_CYCLING)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
Visual Inspection
(VISUAL_INSPECTION)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.

  Stage: Wirebond Protection (alt) (MODULE/WIREBOND_PROTECTION) Alternative

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
IV measurement
(IV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Mass Measurement
(MASS_MEASUREMENT)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Visual Inspection
(VISUAL_INSPECTION)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Wire bonding protection roof envelope
(WP_ENVELOPE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.

  Stage: Post-Parylene Cold (MODULE/POST_PARYLENE_COLD) Complete

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
IV measurement
(IV_MEASURE)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
Visual Inspection
(VISUAL_INSPECTION)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.

  Stage: Post-Parylene Warm (MODULE/POST_PARYLENE_WARM) Complete

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
IV measurement
(IV_MEASURE)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
Visual Inspection
(VISUAL_INSPECTION)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.

  Stage: Parylene Unmasking (MODULE/PARYLENE_UNMASKING) Complete

Test Local Result ProdDB Record
Parylene (de-)masking
(DE_MASKING)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Flatness
(FLATNESS)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
IV measurement
(IV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Visual Inspection
(VISUAL_INSPECTION)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!

  Stage: Parylene Coating (MODULE/PARYLENE_COATING) Complete

Test Local Result ProdDB Record
Parylene Properties
(PARYLENE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Visual Inspection
(VISUAL_INSPECTION)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!

  Stage: Parylene Masking (MODULE/PARYLENE_MASKING) Complete

Test Local Result ProdDB Record
Parylene (de-)masking
(DE_MASKING)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Visual Inspection
(VISUAL_INSPECTION)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!

  Stage: Initial Cold (MODULE/INITIAL_COLD) Complete

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
IV measurement
(IV_MEASURE)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!

  Stage: QC cross-check (module swapping) (MODULE/QC_CROSSCHECK) Complete

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
IV measurement
(IV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.

  Stage: Initial Warm (MODULE/INITIAL_WARM) Complete

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
IV measurement
(IV_MEASURE)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!

  Stage: Wire Bonding (MODULE/WIREBONDING) Complete

Test Local Result ProdDB Record
Visual Inspection
(VISUAL_INSPECTION)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
Wirebond pull test
(WIREBOND_PULL_TEST)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
Wirebonding Information
(WIREBONDING)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.

  Stage: Bare module to module PCB assembly (MODULE/ASSEMBLY) Complete

Test Local Result ProdDB Record
Flatness
(FLATNESS)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Glue Information Module+Flex Attach
(GLUE_MODULE_FLEX_ATTACH)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Mass Measurement
(MASS_MEASUREMENT)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
Quad Module Metrology
(QUAD_MODULE_METROLOGY)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
Triplet Module Metrology
(TRIPLET_METROLOGY)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Visual Inspection
(VISUAL_INSPECTION)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.

  Stage: Initial state to associate flex to bare module (MODULE/INIT) Complete

No tests are allocated for this stage.

LocalDB Test ID Stage Test Name Inspector Date QC Registration
67b7135bccae83c989983973 MODULE/PARYLENE_UNMASKING VISUAL_INSPECTION RichardBates 2025-02-20 03:34:51 PST(-0800) Selected
67b71339d89b87c79ad68173 MODULE/PARYLENE_MASKING VISUAL_INSPECTION RichardBates 2025-02-20 03:34:17 PST(-0800) Selected
67b710efd89b87c79ad67ca9 MODULE/PARYLENE_COATING VISUAL_INSPECTION RichardBates 2025-02-20 03:24:31 PST(-0800) Selected
6792c52a4a8295ecfc0d4b0a MODULE/PARYLENE_UNMASKING VISUAL_INSPECTION KennethWraight 2025-01-24 12:58:35 PST(-0800)
6792c44af101812462641dbc MODULE/PARYLENE_MASKING VISUAL_INSPECTION KennethWraight 2025-01-24 12:58:11 PST(-0800)
6792c4b84a8295ecfc0d4999 MODULE/PARYLENE_COATING VISUAL_INSPECTION KennethWraight 2025-01-24 12:57:21 PST(-0800)
675c8d59888e9d75d458fc08 MODULE/INITIAL_COLD IV_MEASURE Md ArifAbdullaSamy 2024-12-13 14:20:55 PST(-0800) Selected
675cb2b3888e9d75d45900a8 MODULE/INITIAL_COLD E_SUMMARY Md ArifAbdullaSamy 2024-12-13 14:20:52 PST(-0800) Selected
675c8383888e9d75d458fb3b MODULE/FINAL_COLD IV_MEASURE Md ArifAbdullaSamy 2024-12-13 11:36:01 PST(-0800) Selected
675c8bd2888e9d75d458fba5 MODULE/FINAL_COLD E_SUMMARY Md ArifAbdullaSamy 2024-12-13 11:35:58 PST(-0800) Selected
675c506f888e9d75d458f3f4 MODULE/FINAL_WARM IV_MEASURE Md ArifAbdullaSamy 2024-12-13 07:22:52 PST(-0800) Selected
675c509a888e9d75d458f534 MODULE/FINAL_WARM E_SUMMARY Md ArifAbdullaSamy 2024-12-13 07:22:49 PST(-0800) Selected
675c28e2250da57bff9d8734 MODULE/LONG_TERM_STABILITY_TEST LONG_TERM_STABILITY_DCS Md ArifAbdullaSamy 2024-12-13 04:30:26 PST(-0800) Selected
675c0a1b9e4f640bdf7d4fbe MODULE/LONG_TERM_STABILITY_TEST IV_MEASURE Md ArifAbdullaSamy 2024-12-13 04:18:01 PST(-0800) Selected
675c25b5888e9d75d458ef49 MODULE/LONG_TERM_STABILITY_TEST E_SUMMARY Md ArifAbdullaSamy 2024-12-13 04:17:57 PST(-0800) Selected
675b40069e4f640bdf7d4d4d MODULE/THERMAL_CYCLES IV_MEASURE Md ArifAbdullaSamy 2024-12-12 14:53:43 PST(-0800) Selected
675b411c9e4f640bdf7d4d50 MODULE/THERMAL_CYCLES THERMAL_CYCLING Md ArifAbdullaSamy 2024-12-12 14:53:39 PST(-0800) Selected
675b690f9e4f640bdf7d4f31 MODULE/THERMAL_CYCLES E_SUMMARY Md ArifAbdullaSamy 2024-12-12 14:53:37 PST(-0800) Selected
67597c3b9e4f640bdf7d3e8e MODULE/POST_PARYLENE_COLD IV_MEASURE Md ArifAbdullaSamy 2024-12-11 09:20:29 PST(-0800) Selected
6759c9589e4f640bdf7d440e MODULE/POST_PARYLENE_COLD E_SUMMARY Md ArifAbdullaSamy 2024-12-11 09:20:27 PST(-0800) Selected
672b578d4ad52732f125dd04 MODULE/POST_PARYLENE_WARM IV_MEASURE Md ArifAbdullaSamy 2024-12-11 03:28:59 PST(-0800) Selected
6731f0e24ad52732f126101a MODULE/POST_PARYLENE_WARM E_SUMMARY Md ArifAbdullaSamy 2024-12-11 03:28:57 PST(-0800) Selected
6669887d326f980034fc895d MODULE/ASSEMBLY QUAD_MODULE_METROLOGY LiamCunningham 2024-11-25 03:35:40 PST(-0800) Selected
6646140288f02d29ed19eb8e MODULE/INITIAL_WARM IV_MEASURE Md ArifAbdullaSamy 2024-10-06 22:26:04 PDT(-0700) Selected
66ba2ee09086ec0043be275b MODULE/ASSEMBLY MASS_MEASUREMENT LiamCunningham 2024-08-12 08:48:48 PDT(-0700) Selected
66696e16d227fa885f1f6274 MODULE/INITIAL_WARM E_SUMMARY Md ArifAbdullaSamy 2024-07-25 03:26:43 PDT(-0700) Selected
66698ced61ecee003411a827 MODULE/WIREBONDING WIREBOND_PULL_TEST LiamCunningham 2024-06-12 04:56:29 PDT(-0700) Selected
Stage Tests
MODULE/INIT
MODULE/ASSEMBLY
  • Mass Measurement  (MASS_MEASUREMENT)
  • Glue Information Module+Flex Attach  (GLUE_MODULE_FLEX_ATTACH)
  • Triplet Module Metrology  (TRIPLET_METROLOGY)
  • Visual Inspection  (VISUAL_INSPECTION)
  • Flatness  (FLATNESS)
  • Quad Module Metrology  (QUAD_MODULE_METROLOGY)
MODULE/WIREBONDING
  • Wirebonding Information  (WIREBONDING)
  • Wirebond pull test  (WIREBOND_PULL_TEST)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/INITIAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/QC_CROSSCHECK
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/INITIAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/PARYLENE_MASKING
  • Visual Inspection  (VISUAL_INSPECTION)
  • Parylene (de-)masking  (DE_MASKING)
MODULE/PARYLENE_COATING
  • Parylene Properties  (PARYLENE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/PARYLENE_UNMASKING
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Parylene (de-)masking  (DE_MASKING)
MODULE/POST_PARYLENE_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/POST_PARYLENE_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/WIREBOND_PROTECTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Wire bonding protection roof envelope  (WP_ENVELOPE)
  • Mass Measurement  (MASS_MEASUREMENT)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
MODULE/THERMAL_CYCLES
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Thermal Cycling  (THERMAL_CYCLING)
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
MODULE/LONG_TERM_STABILITY_TEST
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Longterm stability DCS  (LONG_TERM_STABILITY_DCS)
MODULE/FINAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/FINAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/FINAL_METROLOGY
  • Flatness  (FLATNESS)
MODULE/QC_STATUS
  • Module ranking  (RANKING)
MODULE/UNHAPPY
MODULE/NOTCONSIDEREDINYIELDS
MODULE/COMPLETE
MODULE/RECEPTION
  • Visual Inspection  (VISUAL_INSPECTION)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/TAB_CUTTING
  • Mass Measurement  (MASS_MEASUREMENT)
  • Module PCB Tab Cutting Information  (CUTTER_PCB_TAB)
  • Visual Inspection  (VISUAL_INSPECTION)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/INIT
OB_LOADED_MODULE_CELL/ASSEMBLY
OB_LOADED_MODULE_CELL/THERMAL_CYCLES
OB_LOADED_MODULE_CELL/FINAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/FINAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/THERMAL_COLD
  • Thermal Measure  (THERMAL_PERFORMANCE)
OB_LOADED_MODULE_CELL/THERMAL_WARM
  • Thermal Measure  (THERMAL_PERFORMANCE)
OB_LOADED_MODULE_CELL/ENVELOPE_CHECK
OB_LOADED_MODULE_CELL/QC_STATUS
OB_LOADED_MODULE_CELL/UNHAPPY
OB_LOADED_MODULE_CELL/COMPLETE
OB_LOADED_MODULE_CELL/RECEPTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/TAB_CUTTING
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Module PCB Tab Cutting Information  (CUTTER_PCB_TAB)
OB_LOADED_MODULE_CELL/PIGTAIL_INSERTION
Back to top page of this component