20UPIMS2102141

MODULE/QC_STATUS

Component Information

Serial Number 20UPIMS2102141
ProdDB ID  7bdf96…8007bf
LocalDB ID 66151279ec873d00355d5cda
Component Type MODULE
Parents No match.
Children 20UPGB12100043 Bare Module 20UPGB12100049 Bare Module 20UPGFC0097845 FE Chip 20UPGB12100051 Bare Module 20UPGFC0097960 FE Chip 20UPIPT3272141 PCB 20UPGFC0097961 FE Chip
Flags
Distribution of chips on wafer

 Properties

Item Value
PCB-Bare Orientation isNormal False
FE chip version 2
Wirebond protection roof presence False
IREFTRIM_FE1 deleted 14
IREFTRIM_FE2 deleted 13
IREFTRIM_FE3 deleted 13
IREFTRIM_FE4 deleted None
Alternative ID None
Rank None

 Comments


Test: THERMAL_CYCLING QC Passed

(Stage: MODULE/THERMAL_CYCLES)


Result of This Test

Scan

Key Data
component id 66151279ec873d00355d5cda
current Stage MODULE/THERMAL_CYCLES
test Type THERMAL_CYCLING
institute 64657cef8d79bac1f3f00596
user name NirajKakoty

Key Data

Results

Key Data
properties {'CYCLING_SPEED': 1, 'MACHINE': 'Chamber Model: DycoMetal CCK-70/180T', 'MAX_TEMP': 40, 'MAX_TEMP_EXT': 60, 'MIN_TEMP': -45, 'MIN_TEMP_EXT': -55, 'NUM_CYCLES': 10, 'NUM_CYCLES_EXT': 1}

RAW Results Record

Download RAW
_id668f922c7459aa3b3c41c433
raw
serialNumbertestTyperesultsstagecomponentdbVersionaddressusersys
20UPIMS2102141THERMAL_CYCLING
property
MACHINEChamber Model: DycoMetal CCK-70/180T
MIN_TEMP-45.0
MAX_TEMP40.0
NUM_CYCLES10
CYCLING_SPEED1.0
MIN_TEMP_EXT-55.0
MAX_TEMP_EXT60.0
NUM_CYCLES_EXT1
comment
Measurements
Metadata
LocalDB version2.2.22
MODULE/THERMAL_CYCLES66151279ec873d00355d5cda1.0164657cef8d79bac1f3f00596Pixel2
mts2024-07-11 08:05:00.976000
cts2024-07-11 08:05:00.976000
rev0
rawHashac12307961d1e64156cab4c1a82ea256
stageMODULE/THERMAL_CYCLES

ProductionDB Record

id668f919b83fcfa00431f9f6e
stateready
stateTs2024-07-11T08:02:35.542Z
stateUserIdentity8194-5792-1
date2024-07-11T08:05:00.000Z
testType
id5ce2a91d91f5f40009847d0f
codeTHERMAL_CYCLING
nameThermal Cycling
stateactive
institution
id5ecf13a093e5ee000a0e5ac6
codeIFAE
nameInstitut de Fisica d'Altes Energies (IFAE)
user
id6555f8e41525bb004261120c
userIdentity8194-5792-1
firstNameNiraj
middleName
lastNameKakoty
runNumber668f922e7459aa3b3c41c434
passedTrue
problemsFalse
properties
  • codeCYCLING_SPEED
    nameThermal Cycling Speed
    dataTypefloat
    valueTypesingle
    requiredFalse
    value1
  • codeMACHINE
    nameMachine
    dataTypestring
    valueTypesingle
    requiredFalse
    valueChamber Model: DycoMetal CCK-70/180T
  • codeMAX_TEMP
    nameMaximum Temperature
    dataTypefloat
    valueTypesingle
    requiredFalse
    value40
    rangeMin-100
    rangeMax100
  • codeMAX_TEMP_EXT
    nameMaximum Temperature Extended cycle range
    dataTypefloat
    valueTypesingle
    requiredFalse
    value60
    rangeMin-100
    rangeMax100
  • codeMIN_TEMP
    nameMinimum Temperature
    dataTypefloat
    valueTypesingle
    requiredFalse
    value-45
    rangeMin-100
    rangeMax100
  • codeMIN_TEMP_EXT
    nameMinimum Temperature Extended cycle range
    dataTypefloat
    valueTypesingle
    requiredFalse
    value-55
    rangeMin-100
    rangeMax100
  • codeNUM_CYCLES
    nameNumber of Cycles
    dataTypeinteger
    valueTypesingle
    requiredFalse
    value10
    rangeMin0
    rangeMax1000
  • codeNUM_CYCLES_EXT
    nameNumber of Cycles Extended cycle Range
    dataTypeinteger
    valueTypesingle
    requiredFalse
    value1
    rangeMin0
    rangeMax1000
resultsNone
cts2024-07-11T08:02:35.542Z
sys
cts2024-07-11T08:02:35.542Z
mts2024-10-06T23:54:35.283Z
rev2
defects
commentsNone
attachments
codedateTimetitledescriptioncontentTypetypebinaryStoreg02filenameuser
602d3cb2d36de559934db4f982bb06882024-07-11T08:02:35.682ZRAWRAWapplication/jsonfileTrue20UPIMS2102141_MODULE__THERMAL_CYCLES_THERMAL_CYCLING_668f919b83fcfa00431f9f6e_668f922c7459aa3b3c41c433.json
id6555f8e41525bb004261120c
userIdentity8194-5792-1
firstNameNiraj
middleName
lastNameKakoty
components
idcodestatestateTsstateUserIdentitydummycompletedcompletedTscompletedUserIdentitytrashedtrashedTstrashedUserIdentityserialNumberalternativeIdentifierprojectsubprojectcomponentTypetypepropertiestestedAtStageinstitution
66151279ec873d00355d5cda7bdf967c09dc84f9c2f5e164328007bfready2024-04-09T10:03:37.502Z7595-2623-1FalseFalseNoneNoneFalseNoneNone20UPIMS2102141None
codeP
namePixels
codePI
nameInner pixels
codeMODULE
nameModule
codeTRIPLET_L0_STAVE_MODULE
nameTriplet L0 stave module
  • codeORIENTATION
    namePCB-Bare Orientation isNormal
    dataTypeboolean
    requiredTrue
    defaultFalse
    valueFalse
  • codeFECHIP_VERSION
    nameFE chip version
    dataTypecodeTable
    requiredTrue
    defaultFalse
    valueITkpix_v1.1
    codeTable
    codevalue
    0RD53A
    1ITkpix_v1
    2ITkpix_v1.1
    3ITkpix_v2
    9No FE chip
  • codeROOF
    nameWirebond protection roof presence
    dataTypeboolean
    requiredFalse
    defaultFalse
    valueFalse
  • codeIREFTRIM_FE1
    nameIREFTRIM_FE1
    value14
  • codeIREFTRIM_FE2
    nameIREFTRIM_FE2
    value13
  • codeIREFTRIM_FE3
    nameIREFTRIM_FE3
    value13
  • codeIREFTRIM_FE4
    nameIREFTRIM_FE4
    valueNone
codeMODULE/THERMAL_CYCLES
nameThermal Cycles
order12
initialFalse
finalFalse
codeIFAE
nameInstitut de Fisica d'Altes Energies (IFAE)

 Current Stage: Ranking of the module

Test Type Local Result
Module ranking
(RANKING)
No TestRun!

 Candidate TestRuns of this Stage

LDB ID TestRun Code QC Passed Inspector Measurement Date Analysis Date Analysis Version Tags QC Registration
668f92…41c434 THERMAL_CYCLING Pass NirajKakoty N/A a year ago No tags Selected
668f92…41c431 E_SUMMARY Fail NirajKakoty N/A a year ago 2.2.22 No tags Selected

Past QC Stages and Results

Final flatness measurement (MODULE/FINAL_METROLOGY)

Final Cold (MODULE/FINAL_COLD)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered

Final Warm (MODULE/FINAL_WARM)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered

Long Term Stability Test (MODULE/LONG_TERM_STABILITY_TEST)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered
Longterm stability DCS
(LONG_TERM_STABILITY_DCS)
No result N/A

Thermal Cycles (MODULE/THERMAL_CYCLES)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
Flatness
(FLATNESS)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Thermal Cycling
(THERMAL_CYCLING)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Post-Parylene Cold (MODULE/POST_PARYLENE_COLD)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A

Post-Parylene Warm (MODULE/POST_PARYLENE_WARM)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A

Wirebond Protection (alt) (MODULE/WIREBOND_PROTECTION)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Mass Measurement
(MASS_MEASUREMENT)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
No result N/A
Wire bonding protection roof envelope
(WP_ENVELOPE)
No result N/A

Parylene Unmasking (MODULE/PARYLENE_UNMASKING)

Test Local Result ProdDB Record
Parylene (de-)masking
(DE_MASKING)
No result N/A
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
Flatness
(FLATNESS)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Parylene Coating (MODULE/PARYLENE_COATING)

Test Local Result ProdDB Record
Parylene Properties
(PARYLENE)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Parylene Masking (MODULE/PARYLENE_MASKING)

Test Local Result ProdDB Record
Parylene (de-)masking
(DE_MASKING)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Initial Cold (MODULE/INITIAL_COLD)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
No result N/A

QC cross-check (module swapping) (MODULE/QC_CROSSCHECK)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
No result N/A
IV measurement
(IV_MEASURE)
No result N/A

Initial Warm (MODULE/INITIAL_WARM)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
No result N/A

Wire Bonding (MODULE/WIREBONDING)

Test Local Result ProdDB Record
Visual Inspection
(VISUAL_INSPECTION)
No result N/A
Wirebond pull test
(WIREBOND_PULL_TEST)
No result N/A
Wirebonding Information
(WIREBONDING)
No result N/A

Bare module to module PCB assembly (MODULE/ASSEMBLY)

Test Local Result ProdDB Record
Flatness
(FLATNESS)
No result N/A
Glue Information Module+Flex Attach
(GLUE_MODULE_FLEX_ATTACH)
No result N/A
Mass Measurement
(MASS_MEASUREMENT)
No result N/A
Quad Module Metrology
(QUAD_MODULE_METROLOGY)
No result N/A
Triplet Module Metrology
(TRIPLET_METROLOGY)
Registered Registered
Visual Inspection
(VISUAL_INSPECTION)
No result N/A

Initial state to associate flex to bare module (MODULE/INIT)

LocalDB Test ID Stage Test Name Inspector Measurement Date Analysis Date Tags QC Registration
66992e…e36efa MODULE/FINAL_COLD IV_MEASURE NirajKakoty a year ago a year ago No tags Selected
669913…e36ebf MODULE/FINAL_WARM IV_MEASURE NirajKakoty a year ago a year ago No tags Selected
668fa5…41cafa MODULE/LONG_TERM_STABILITY_TEST IV_MEASURE NirajKakoty a year ago a year ago No tags Selected
668f92…41c434 MODULE/THERMAL_CYCLES THERMAL_CYCLING NirajKakoty N/A a year ago No tags Selected
669937…e3740e MODULE/FINAL_COLD E_SUMMARY NirajKakoty N/A a year ago No tags Selected
669913…e36ec1 MODULE/FINAL_WARM E_SUMMARY NirajKakoty N/A a year ago No tags Selected
668fa5…41cafc MODULE/LONG_TERM_STABILITY_TEST E_SUMMARY NirajKakoty N/A a year ago No tags Selected
668f92…41c431 MODULE/THERMAL_CYCLES E_SUMMARY NirajKakoty N/A a year ago No tags Selected
666968…e5fba2 MODULE/INITIAL_COLD E_SUMMARY JuanIgnacioCarlotto N/A a year ago No tags Selected
666966…e5f7a9 MODULE/INITIAL_WARM E_SUMMARY JuanIgnacioCarlotto N/A a year ago No tags Selected
66166f…c7de6c MODULE/ASSEMBLY TRIPLET_METROLOGY PabloFernández Martínez N/A a year ago No tags Selected
Stage Tests
MODULE/INIT
MODULE/ASSEMBLY
  • Mass Measurement  (MASS_MEASUREMENT)
  • Glue Information Module+Flex Attach  (GLUE_MODULE_FLEX_ATTACH)
  • Triplet Module Metrology  (TRIPLET_METROLOGY)
  • Visual Inspection  (VISUAL_INSPECTION)
  • Flatness  (FLATNESS)
  • Quad Module Metrology  (QUAD_MODULE_METROLOGY)
MODULE/WIREBONDING
  • Wirebonding Information  (WIREBONDING)
  • Wirebond pull test  (WIREBOND_PULL_TEST)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/INITIAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/QC_CROSSCHECK
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/INITIAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/PARYLENE_MASKING
  • Visual Inspection  (VISUAL_INSPECTION)
  • Parylene (de-)masking  (DE_MASKING)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/PARYLENE_COATING
  • Parylene Properties  (PARYLENE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/PARYLENE_UNMASKING
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Parylene (de-)masking  (DE_MASKING)
MODULE/WIREBOND_PROTECTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Wire bonding protection roof envelope  (WP_ENVELOPE)
  • Mass Measurement  (MASS_MEASUREMENT)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
MODULE/POST_PARYLENE_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/POST_PARYLENE_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/THERMAL_CYCLES
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Thermal Cycling  (THERMAL_CYCLING)
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
MODULE/LONG_TERM_STABILITY_TEST
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Longterm stability DCS  (LONG_TERM_STABILITY_DCS)
MODULE/FINAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/FINAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/FINAL_METROLOGY
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/QC_STATUS
  • Module ranking  (RANKING)
MODULE/UNHAPPY
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/NOTCONSIDEREDINYIELDS
MODULE/GRAVEYARD
MODULE/COMPLETE
MODULE/RECEPTION
  • Visual Inspection  (VISUAL_INSPECTION)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/TAB_CUTTING
  • Mass Measurement  (MASS_MEASUREMENT)
  • Module PCB Tab Cutting Information  (CUTTER_PCB_TAB)
  • Visual Inspection  (VISUAL_INSPECTION)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
LLS/PRE_TC_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/PRE_TC_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/POST_TC_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/POST_TC_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/RECEPTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
OB_LOADED_MODULE_CELL/INIT
OB_LOADED_MODULE_CELL/ASSEMBLY
OB_LOADED_MODULE_CELL/THERMAL_CYCLES
OB_LOADED_MODULE_CELL/FINAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/FINAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/THERMAL_COLD
  • Thermal Measure  (THERMAL_PERFORMANCE)
OB_LOADED_MODULE_CELL/THERMAL_WARM
  • Thermal Measure  (THERMAL_PERFORMANCE)
OB_LOADED_MODULE_CELL/ENVELOPE_CHECK
OB_LOADED_MODULE_CELL/QC_STATUS
OB_LOADED_MODULE_CELL/UNHAPPY
OB_LOADED_MODULE_CELL/COMPLETE
OB_LOADED_MODULE_CELL/RECEPTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/TAB_CUTTING
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Module PCB Tab Cutting Information  (CUTTER_PCB_TAB)
OB_LOADED_MODULE_CELL/PIGTAIL_INSERTION
Back to top page of this component