20UPGM22110303

MODULE/INITIAL_COLD

Component Information

Serial Number 20UPGM22110303
ProdDB ID  d230ed…cd7214
LocalDB ID 655f30d65f9f8800384e8035
Component Type MODULE
Parents No match.
Children 20UPGB42200012 Bare Module 20UPGFC0096418 FE Chip 20UPGFC0096307 FE Chip 20UPGFC0096339 FE Chip 20UPGFC0096323 FE Chip 20UPGPQ2110303 PCB
Flags
Distribution of chips on wafer

 Properties

Item Value
PCB-Bare Orientation isNormal True
FE chip version 2
Wirebond protection roof presence False
IREF Trim Bit FE1 deleted None
IREF Trim Bit FE2 deleted None
IREF Trim Bit FE3 deleted None
IREF Trim Bit FE4 deleted None

 Comments


Test: WIREBOND_PULL_TEST QC Passed

(Stage: MODULE/WIREBONDING)


Result of Wirebond Pull Test

Scan

Key Data
component id 655f30d65f9f8800384e8035
Stage MODULE/WIREBONDING
test Type WIREBOND_PULL_TEST
institute 64657cef8d79bac1f3f00584
user FrancescoCrescioli

Result

Key Data
properties {'ANALYSIS_VERSION': '1.0.11', 'INSTRUMENT': 'Bondtech', 'OPERATOR': 'Pascal Corona'} g
BOND_PEEL 0 g
HEEL_BREAKS_ON_FE_CHIP 0 g
HEEL_BREAKS_ON_PCB 100 g
PULL_STRENGTH 7.798 g
PULL_STRENGTH_ERROR 1.8580802518250448 g
PULL_STRENGTH_GRADING <span class="badge badge-warning">N/A</span> g
PULL_STRENGTH_MAX 9.39 g
PULL_STRENGTH_MIN 4.46 g
WIRE_BREAKS_5G 1 g
WIRE_PULLS 10 g

RAW Results Record

Download RAW
_id659d4d2ea94269cc065c73e9
raw
serialNumbertestTyperesultsstagecomponentdbVersionaddresssys
20UPGM22110303WIREBOND_PULL_TEST
property
OPERATORPascal Corona
INSTRUMENTBondtech
ANALYSIS_VERSIONNone
comment
metadata
QCHELPER_VERSION4.0.dev1
MODULE_SN20UPGM22110303
pull_data
strengthbreak_mode
5.46Heel break on hybrid
8.82Heel break on hybrid
5.69Heel break on hybrid
7.97Heel break on hybrid
4.46Heel break on hybrid
9.39Heel break on hybrid
9.2Heel break on hybrid
8.73Heel break on hybrid
9.01Heel break on hybrid
9.25Heel break on hybrid
Metadata
Measurements
WIRE_PULLSNone
PULL_STRENGTHNone
PULL_STRENGTH_ERRORNone
WIRE_BREAKS_5GNone
PULL_STRENGTH_MINNone
PULL_STRENGTH_MAXNone
HEEL_BREAKS_ON_FE_CHIPNone
HEEL_BREAKS_ON_PCBNone
BOND_PEELNone
PULL_STRENGTH_GRADINGNone
MODULE/WIREBONDING655f30d65f9f8800384e80351.0164657cef8d79bac1f3f00584
mts2024-01-09 13:42:06.536000
cts2024-01-09 13:42:06.536000
rev0
rawHash83687972c6c399de84a6a807afee96e9
stageMODULE/WIREBONDING

ProductionDB Record

id65b22605d5a3cd0042d67a77
stateready
stateTs2024-01-25T09:12:37.778Z
stateUserIdentity9086-39-1
date2024-01-09T13:42:00.000Z
testType
id63fb635d4069b50036d3faac
codeWIREBOND_PULL_TEST
nameWirebond pull test
stateactive
institution
id5d42fb891fd678000a409866
codeLPNHE
nameLaboratoire de Physique Nucléaire et de Hautes Energies
user
id5e98594f8bc0cb000ba8d3a8
userIdentity9086-39-1
firstNameFrancesco
middleName
lastNameCrescioli
runNumber659d4d2fa94269cc065c73ea
passedTrue
problemsFalse
properties
codenamedataTypevalueTyperequiredvaluerangeMinrangeMax
ANALYSIS_VERSIONAnalysis VersionstringsingleFalse1.0.11NoneNone
INSTRUMENTInstrumentstringsingleFalseBondtechNoneNone
OPERATOROperatorstringsingleFalsePascal CoronaNoneNone
results
  • codeBOND_PEEL
    namePercentage of bond peel on FE chip or PCB [%]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value0
    associateChildNone
  • codeHEEL_BREAKS_ON_FE_CHIP
    namePercentage of heel breaks on FE chips [%]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value0
    associateChildNone
  • codeHEEL_BREAKS_ON_PCB
    namePercentage of heel breaks on PCB [%]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value100
    associateChildNone
  • codePULL_STRENGTH
    nameMean pull strength [g]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value7.798
    associateChildNone
  • codePULL_STRENGTH_ERROR
    nameStd deviation of pull strength [g]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value1.8580802518250448
    associateChildNone
  • codePULL_STRENGTH_GRADING
    namePull strength grade data array
    order1
    dataTypefloat
    valueTypearray
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    valueNone
    associateChildNone
  • codePULL_STRENGTH_MAX
    nameMaximum pull strength [g]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value9.39
    associateChildNone
  • codePULL_STRENGTH_MIN
    nameMinimum pull strength [g]
    dataTypefloat
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value4.46
    associateChildNone
  • codeWIRE_BREAKS_5G
    nameNumber of wires breaking before 5g
    dataTypeinteger
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value1
    associateChildNone
  • codeWIRE_PULLS
    nameNumber of wires pulled
    dataTypeinteger
    valueTypesingle
    arrayDimensionsNone
    additionalFalse
    rangeMinNone
    rangeMaxNone
    value10
    associateChildNone
cts2024-01-25T09:12:37.778Z
sys
cts2024-01-25T09:12:37.778Z
mts2024-01-25T09:12:37.914Z
rev1
defects
commentsNone
attachments
codedateTimetitledescriptioncontentTypetypefilenameuser
b4984b7be2df1648482929a82006be332024-01-25T09:12:37.904ZRAWRAWtext/plainfile20UPGM22110303_MODULE__WIREBONDING_WIREBOND_PULL_TEST_65b22605d5a3cd0042d67a77_659d4d2ea94269cc065c73e9.json
id5e98594f8bc0cb000ba8d3a8
userIdentity9086-39-1
firstNameFrancesco
middleName
lastNameCrescioli
components
idcodestatestateTsstateUserIdentitydummycompletedcompletedTscompletedUserIdentitytrashedtrashedTstrashedUserIdentityserialNumberalternativeIdentifierprojectsubprojectcomponentTypetypepropertiestestedAtStageinstitution
655f30d65f9f8800384e8035d230ed85b2bc18a9eb693303cdcd7214ready2023-11-23T11:00:38.582Z9086-39-1FalseFalseNoneNoneFalseNoneNone20UPGM22110303None
codeP
namePixels
codePG
namePixel general
codeMODULE
nameModule
codeOUTER_SYSTEM_QUAD_MODULE
nameOuter system quad module
  • codeORIENTATION
    namePCB-Bare Orientation isNormal
    dataTypeboolean
    requiredTrue
    defaultFalse
    valueTrue
  • codeFECHIP_VERSION
    nameFE chip version
    dataTypecodeTable
    requiredTrue
    defaultFalse
    valueITkpix_v1.1
    codeTable
    codevalue
    0RD53A
    1ITkpix_v1
    2ITkpix_v1.1
    3ITkpix_v2
    9No FE chip
  • codeROOF
    nameWirebond protection roof presence
    dataTypeboolean
    requiredFalse
    defaultFalse
    valueFalse
  • codeIREFTRIM_FE1
    nameIREF Trim Bit FE1
    dataTypeinteger
    requiredFalse
    defaultFalse
    valueNone
  • codeIREFTRIM_FE2
    nameIREF Trim Bit FE2
    dataTypeinteger
    requiredFalse
    defaultFalse
    valueNone
  • codeIREFTRIM_FE3
    nameIREF Trim Bit FE3
    dataTypeinteger
    requiredFalse
    defaultFalse
    valueNone
  • codeIREFTRIM_FE4
    nameIREF Trim Bit FE4
    dataTypeinteger
    requiredFalse
    defaultFalse
    valueNone
codeMODULE/WIREBONDING
nameWire Bonding
order2
initialFalse
finalFalse
codeLPNHE
nameLaboratoire de Physique Nucléaire et de Hautes Energies

 Current Stage: Initial Cold

Test Type Local Result
Electrical Test (e-test) Module Summary
(E_SUMMARY)
TestRun Present
IV measurement
(IV_MEASURE)
TestRun Present

 Candidate TestRuns of this Stage

LDB ID TestRun Code QC Passed Inspector Measurement Date Analysis Date Analysis Version Tags QC Registration
65aa5b…41daa5 VISUAL_INSPECTION Pass FrancescoCrescioli N/A a year ago 1.0.11 No tags Selected
659d4d…5c73ea WIREBOND_PULL_TEST Pass FrancescoCrescioli N/A a year ago 1.0.11 No tags Selected
659fb9…3a44ec WIREBONDING Pass FrancescoCrescioli N/A a year ago No tags Selected

Past QC Stages and Results

QC cross-check (module swapping) (MODULE/QC_CROSSCHECK)

Initial Warm (MODULE/INITIAL_WARM)

Test Local Result ProdDB Record
Electrical Test (e-test) Module Summary
(E_SUMMARY)
Registered Registered
IV measurement
(IV_MEASURE)
Registered Registered

Wire Bonding (MODULE/WIREBONDING)

Test Local Result ProdDB Record
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered
Wirebond pull test
(WIREBOND_PULL_TEST)
Registered Registered
Wirebonding Information
(WIREBONDING)
Registered Registered

Bare module to module PCB assembly (MODULE/ASSEMBLY)

Test Local Result ProdDB Record
Flatness
(FLATNESS)
No result N/A
Glue Information Module+Flex Attach
(GLUE_MODULE_FLEX_ATTACH)
No result N/A
Mass Measurement
(MASS_MEASUREMENT)
Registered Registered
Quad Module Metrology
(QUAD_MODULE_METROLOGY)
Registered Registered
Triplet Module Metrology
(TRIPLET_METROLOGY)
No result N/A
Visual Inspection
(VISUAL_INSPECTION)
Registered Registered

Initial state to associate flex to bare module (MODULE/INIT)

LocalDB Test ID Stage Test Name Inspector Measurement Date Analysis Date Tags QC Registration
65b127…211f0b MODULE/INITIAL_COLD IV_MEASURE FrancescoCrescioli N/A a year ago No tags Selected
65b127…211f0c MODULE/INITIAL_COLD E_SUMMARY FrancescoCrescioli N/A a year ago No tags Selected
65b116…1dacaf MODULE/INITIAL_WARM IV_MEASURE FrancescoCrescioli N/A a year ago No tags Selected
65aa68…183ca8 MODULE/INITIAL_WARM E_SUMMARY FrancescoCrescioli N/A a year ago No tags Selected
65aa5b…41daa5 MODULE/WIREBONDING VISUAL_INSPECTION FrancescoCrescioli N/A a year ago No tags Selected
659d4d…5c73ea MODULE/WIREBONDING WIREBOND_PULL_TEST FrancescoCrescioli N/A a year ago No tags Selected
659fb9…3a44ec MODULE/WIREBONDING WIREBONDING FrancescoCrescioli N/A a year ago No tags Selected
65b10f…1daca6 MODULE/ASSEMBLY VISUAL_INSPECTION FrancescoCrescioli N/A a year ago No tags Selected
6560bb…67e439 MODULE/ASSEMBLY MASS_MEASUREMENT FrancescoCrescioli N/A a year ago No tags Selected
657307…534109 MODULE/ASSEMBLY QUAD_MODULE_METROLOGY FrancescoCrescioli N/A 2 years ago No tags Selected
Stage Tests
MODULE/INIT
MODULE/ASSEMBLY
  • Mass Measurement  (MASS_MEASUREMENT)
  • Glue Information Module+Flex Attach  (GLUE_MODULE_FLEX_ATTACH)
  • Triplet Module Metrology  (TRIPLET_METROLOGY)
  • Visual Inspection  (VISUAL_INSPECTION)
  • Flatness  (FLATNESS)
  • Quad Module Metrology  (QUAD_MODULE_METROLOGY)
MODULE/WIREBONDING
  • Wirebonding Information  (WIREBONDING)
  • Wirebond pull test  (WIREBOND_PULL_TEST)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/INITIAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/QC_CROSSCHECK
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/INITIAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/PARYLENE_MASKING
  • Visual Inspection  (VISUAL_INSPECTION)
  • Parylene (de-)masking  (DE_MASKING)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/PARYLENE_COATING
  • Parylene Properties  (PARYLENE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/PARYLENE_UNMASKING
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Parylene (de-)masking  (DE_MASKING)
MODULE/WIREBOND_PROTECTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Wire bonding protection roof envelope  (WP_ENVELOPE)
  • Mass Measurement  (MASS_MEASUREMENT)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
MODULE/POST_PARYLENE_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/POST_PARYLENE_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/THERMAL_CYCLES
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • Thermal Cycling  (THERMAL_CYCLING)
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
MODULE/LONG_TERM_STABILITY_TEST
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Longterm stability DCS  (LONG_TERM_STABILITY_DCS)
MODULE/FINAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/FINAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Visual Inspection  (VISUAL_INSPECTION)
MODULE/FINAL_METROLOGY
  • Flatness  (FLATNESS)
  • Visual Inspection  (VISUAL_INSPECTION)
  • IV measurement  (IV_MEASURE)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
MODULE/QC_STATUS
  • Module ranking  (RANKING)
MODULE/UNHAPPY
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/NOTCONSIDEREDINYIELDS
MODULE/GRAVEYARD
MODULE/COMPLETE
MODULE/RECEPTION
  • Visual Inspection  (VISUAL_INSPECTION)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
MODULE/TAB_CUTTING
  • Mass Measurement  (MASS_MEASUREMENT)
  • Module PCB Tab Cutting Information  (CUTTER_PCB_TAB)
  • Visual Inspection  (VISUAL_INSPECTION)
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
LLS/PRE_TC_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/PRE_TC_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/POST_TC_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/POST_TC_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
LLS/RECEPTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
OB_LOADED_MODULE_CELL/INIT
OB_LOADED_MODULE_CELL/ASSEMBLY
OB_LOADED_MODULE_CELL/THERMAL_CYCLES
OB_LOADED_MODULE_CELL/FINAL_WARM
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/FINAL_COLD
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/THERMAL_COLD
  • Thermal Measure  (THERMAL_PERFORMANCE)
OB_LOADED_MODULE_CELL/THERMAL_WARM
  • Thermal Measure  (THERMAL_PERFORMANCE)
OB_LOADED_MODULE_CELL/ENVELOPE_CHECK
OB_LOADED_MODULE_CELL/QC_STATUS
OB_LOADED_MODULE_CELL/UNHAPPY
OB_LOADED_MODULE_CELL/COMPLETE
OB_LOADED_MODULE_CELL/RECEPTION
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
OB_LOADED_MODULE_CELL/TAB_CUTTING
  • Electrical Test (e-test) Module Summary  (E_SUMMARY)
  • IV measurement  (IV_MEASURE)
  • Module PCB Tab Cutting Information  (CUTTER_PCB_TAB)
OB_LOADED_MODULE_CELL/PIGTAIL_INSERTION
Back to top page of this component