Top Page > Component List > 20UPIS07100092 > QC Result / sensor_manufacturer / IV_MEASURE


20UPIS07100092
L0-3D-25x100-Sensor
  ITkPD Component Page Jump to ITkPD component page

Component Information

Item Value
Serial Number 20UPIS07100092
Production DB Component ID 907433d5a6129db02c6d8afab59dad7e
LocalDB Component ID 644129cad88aa000380b7ab9
Component Type sensor_tile
Super-Component 20UPGB12100043
Sub-Components No match.
Flags

Properties

Item Data Type Value
Main Vendor integer 7
Sensor Type or Test Structure integer 1
Version of component string pre-production
Scratch id (to be used if not the same as agreed manufacturer ID) string 2010-11325
Alternative Identifier string V8-1-022109-1-011
Original Manufacturer ID string K
Breakdown Voltage (-999 if no breakdown occurred) float None
Depletion Voltage (V) float None

Comments


Test: IV_MEASURE QC Passed

(Stage: sensor_manufacturer)


Basic View Only: custom view for this TestRun is not prepared.

Metadata

Key Data
QC Passed True
Date 2023-04-20 05:17:39 PDT(-0700)
component ObjectId 644129cad88aa000380b7ab9
Stage sensor_manufacturer
Test Type IV_MEASURE
Institute ObjectId
User Name StefanoTerzo
ObjectId of this record 64412d630ca03e00368d538b
ObjectId of RAW record None

Results

Key Data
ANALYSIS_VERSION mqat vDCYIHNWFJHTHCXIKJJIZADCLUFAVLR
HUM 0
TEMP 24
BREAKDOWN_VOLTAGE 73
IV_ARRAY {'time': [0, 2, 4, 6, 8, 10, 12, 14, 16, 18, 20, 22, 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44, 46, 48, 50, 52, 54, 56, 58, 60, 62, 64, 66, 68, 70, 72, 74, 76, 78, 80, 82, 84, 86, 88, 90, 92, 94, 96, 98, 100, 102, 104, 106, 108, 110, 112, 114, 116, 118, 120, 122, 124, 126, 128, 130, 132, 134, 136, 138, 140, 142, 144, 146, 148, 150, 152, 154, 156, 158, 160, 162, 164, 166, 168, 170, 172, 174, 176, 178, 180, 182, 184, 186, 188, 190, 192, 194, 196, 198, 200, 202, 204, 206, 208, 210, 212, 214, 216, 218, 220, 222, 224, 226, 228, 230, 232, 234, 236, 238, 240], 'voltage': [0, 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22, 23, 24, 25, 26, 27, 28, 29, 30, 31, 32, 33, 34, 35, 36, 37, 38, 39, 40, 41, 42, 43, 44, 45, 46, 47, 48, 49, 50, 51, 52, 53, 54, 55, 56, 57, 58, 59, 60, 61, 62, 63, 64, 65, 66, 67, 68, 69, 70, 71, 72, 73, 74, 75, 76, 77, 78, 79, 80, 81, 82, 83, 84, 85, 86, 87, 88, 89, 90, 91, 92, 93, 94, 95, 96, 97, 98, 99, 100, 101, 102, 103, 104, 105, 106, 107, 108, 109, 110, 111, 112, 113, 114, 115, 116, 117, 118, 119, 120], 'current': [0.010715, 0.110926, 0.18151599999999998, 0.249323, 0.298773, 0.337481, 0.367802, 0.391894, 0.412271, 0.430159, 0.446268, 0.46139199999999997, 0.475697, 0.489307, 0.502589, 0.5154799999999999, 0.5279119999999999, 0.540184, 0.552246, 0.564063, 0.575818, 0.587474, 0.599047, 0.610483, 0.6219549999999999, 0.633401, 0.64472, 0.656134, 0.667546, 0.678879, 0.6903020000000001, 0.701769, 0.713163, 0.724678, 0.736212, 0.7477919999999999, 0.759331, 0.771029, 0.782764, 0.794585, 0.806438, 0.818301, 0.830335, 0.8424389999999999, 0.854605, 0.8668130000000001, 0.879184, 0.891675, 0.90441, 0.9174829999999999, 0.930794, 0.943985, 0.9571900000000001, 0.9703569999999999, 0.983817, 0.9972899999999999, 1.011, 1.025, 1.039, 1.053, 1.068, 1.083, 1.0979999999999999, 1.113, 1.129, 1.145, 1.1620000000000001, 1.18, 1.198, 1.2169999999999999, 1.238, 1.262, 1.2890000000000001, 1.327, 1.3900000000000001, 1.5170000000000001, 1.804, 2.34, 3.206, 4.4639999999999995, 6.164, 8.297, 10.774000000000001, 13.449, 16.109, 18.657, 21.282999999999998, 24.145, 27.37, 30.951999999999998, 34.955, 39.241, 43.602, 47.923, 52.241, 56.576, 60.793, 65.09299999999999, 69.51, 73.932, 78.22699999999999, 82.624, 87.032, 91.407, 95.949, 100.327, 104.78099999999999, 109.22999999999999, 113.7, 118.045, 122.481, 127.01100000000001, 131.401, 135.745, 140.20600000000002, 144.67200000000003, 149.163, 153.655, 157.991, 162.447, 166.94], 'sigma current': [], 'temperature': [24], 'humidity': []}
IV_IMG afcdb6bfe80634b8bfbb624bacbb0c600c809f7050576b0b4e6806cc26c2f04b
LEAK_CURRENT 0.599047

ProductionDB Record

{}

Current Stage: Final flatness measurement

No tests are allocated for this stage.


Past QC Stages and Results

  Stage: Final Cold (MODULE/FINAL_COLD) Complete

No tests are allocated for this stage.

  Stage: Final Warm (MODULE/FINAL_WARM) Complete

No tests are allocated for this stage.

  Stage: Long Term Stability Test (MODULE/LONG_TERM_STABILITY_TEST) Complete

No tests are allocated for this stage.

  Stage: Thermal Cycles (MODULE/THERMAL_CYCLES) Complete

No tests are allocated for this stage.

  Stage: Wirebond Protection (alt) (MODULE/WIREBOND_PROTECTION) Complete

No tests are allocated for this stage.

  Stage: Post-Parylene Cold (MODULE/POST_PARYLENE_COLD) Complete

No tests are allocated for this stage.

  Stage: Post-Parylene Warm (MODULE/POST_PARYLENE_WARM) Complete

No tests are allocated for this stage.

  Stage: Parylene Unmasking (MODULE/PARYLENE_UNMASKING) Complete

No tests are allocated for this stage.

  Stage: Parylene Coating (MODULE/PARYLENE_COATING) Complete

No tests are allocated for this stage.

  Stage: Parylene Masking (MODULE/PARYLENE_MASKING) Locally Signed Off

No tests are allocated for this stage.

  Stage: Initial Cold (MODULE/INITIAL_COLD) Locally Signed Off

No tests are allocated for this stage.

  Stage: QC cross-check (module swapping) (MODULE/QC_CROSSCHECK) Alternative

No tests are allocated for this stage.

  Stage: Initial Warm (MODULE/INITIAL_WARM) Complete

No tests are allocated for this stage.

  Stage: Wire Bonding (MODULE/WIREBONDING) Locally Signed Off

No tests are allocated for this stage.

  Stage: Bare module to module PCB assembly (MODULE/ASSEMBLY) Complete

No tests are allocated for this stage.

  Stage: Initial state to associate flex to bare module (MODULE/INIT) Locally Signed Off

No tests are allocated for this stage.

  Stage: Bare module reception at ITk institute (BAREMODULERECEPTION) Complete

Test Local Result ProdDB Record
IV measurement
(IV_MEASURE)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!

  Stage: Bare Module Assembly (BAREMODULEASSEMBLY) Locally Signed Off

No tests are allocated for this stage.

  Stage: Not to be used for detector (NOT_USED) Alternative

No tests are allocated for this stage.

  Stage: Post Irradiation (POST_IRRAD) Alternative

Test Local Result ProdDB Record
CV measurement
(CV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
IV measurement
(IV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.

  Stage: QA at Institutes (QA) Alternative

Test Local Result ProdDB Record
CV measurement
(CV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Inter-pixel capacitance
(INTER-PIXEL_CAPACITANCE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Inter-pixel resistance
(INTER-PIXEL_RESISTANCE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
IT measurement
(IT_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
IV measurement
(IV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Sensor Metrology: Sensor bow and thickness
(SENSOR_METROLOGY)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.

  Stage: Wafer Processing (dicing, UBM, flip-chip) (WAFER_PROCESSING) Complete

Test Local Result ProdDB Record
CV measurement
(CV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
IV measurement
(IV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Sensor Metrology: Sensor bow and thickness
(SENSOR_METROLOGY)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Visual inspection
(VISUAL_INSPECTION)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.

  Stage: Sensor Manufacturer (sensor_manufacturer) Complete

Test Local Result ProdDB Record
CV measurement
(CV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
IV measurement
(IV_MEASURE)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
LocalDB Test ID Stage Test Name Inspector Date QC Registration
657867c8822c6e00426a3539 BAREMODULERECEPTION IV_MEASURE MarioJose 2023-12-12 06:01:44 PST(-0800) Selected
64412d630ca03e00368d538b sensor_manufacturer IV_MEASURE StefanoTerzo 2023-04-20 05:17:39 PDT(-0700) Selected
Stage Tests
sensor_manufacturer
  • CV measurement  (CV_MEASURE)
  • IV measurement  (IV_MEASURE)
WAFER_PROCESSING
  • Visual inspection  (VISUAL_INSPECTION)
  • Sensor Metrology: Sensor bow and thickness  (SENSOR_METROLOGY)
  • IV measurement  (IV_MEASURE)
  • CV measurement  (CV_MEASURE)
QA
  • CV measurement  (CV_MEASURE)
  • IV measurement  (IV_MEASURE)
  • IT measurement  (IT_MEASURE)
  • Inter-pixel capacitance  (INTER-PIXEL_CAPACITANCE)
  • Inter-pixel resistance  (INTER-PIXEL_RESISTANCE)
  • Sensor Metrology: Sensor bow and thickness  (SENSOR_METROLOGY)
POST_IRRAD
  • IV measurement  (IV_MEASURE)
  • CV measurement  (CV_MEASURE)
NOT_USED
BAREMODULEASSEMBLY
BAREMODULERECEPTION
  • IV measurement  (IV_MEASURE)
MODULE/INIT
MODULE/ASSEMBLY
MODULE/WIREBONDING
MODULE/INITIAL_WARM
MODULE/QC_CROSSCHECK
MODULE/INITIAL_COLD
MODULE/PARYLENE_MASKING
MODULE/PARYLENE_COATING
MODULE/PARYLENE_UNMASKING
MODULE/POST_PARYLENE_WARM
MODULE/POST_PARYLENE_COLD
MODULE/WIREBOND_PROTECTION
MODULE/THERMAL_CYCLES
MODULE/LONG_TERM_STABILITY_TEST
MODULE/FINAL_WARM
MODULE/FINAL_COLD
MODULE/FINAL_METROLOGY
MODULE/QC_STATUS
MODULE/UNHAPPY
MODULE/NOTCONSIDEREDINYIELDS
MODULE/COMPLETE
MODULE/RECEPTION
MODULE/TAB_CUTTING
OB_LOADED_MODULE_CELL/INIT
OB_LOADED_MODULE_CELL/ASSEMBLY
OB_LOADED_MODULE_CELL/THERMAL_CYCLES
OB_LOADED_MODULE_CELL/FINAL_WARM
OB_LOADED_MODULE_CELL/FINAL_COLD
OB_LOADED_MODULE_CELL/THERMAL_COLD
OB_LOADED_MODULE_CELL/THERMAL_WARM
OB_LOADED_MODULE_CELL/ENVELOPE_CHECK
OB_LOADED_MODULE_CELL/QC_STATUS
OB_LOADED_MODULE_CELL/UNHAPPY
OB_LOADED_MODULE_CELL/COMPLETE
OB_LOADED_MODULE_CELL/RECEPTION
OB_LOADED_MODULE_CELL/TAB_CUTTING
OB_LOADED_MODULE_CELL/PIGTAIL_INSERTION
Back to top page of this component