Top Page > Component List > 20UPGS33300499 > QC Result / sensor_manufacturer / IV_MEASURE
Item | Value |
---|---|
Serial Number | 20UPGS33300499 |
Production DB Component ID | 620221926aecc2f83848cd0c2eae920f |
LocalDB Component ID | 6426d4f1d8244a0036f6d428 |
Component Type | sensor_tile |
Super-Component | 20UPGB43000017 |
Sub-Components | No match. |
Flags |
Key | Data |
---|---|
QC Passed | True |
Date | 2023-04-12 05:12:29 PDT(-0700) |
component ObjectId | 6426d4f1d8244a0036f6d428 |
Stage | sensor_manufacturer |
Test Type | IV_MEASURE |
Institute ObjectId | |
User Name | ChristopherKrause |
ObjectId of this record | 6436a02dd88aa00038d39fe3 |
ObjectId of RAW record | None |
Key | Data |
---|---|
ANALYSIS_VERSION | mqat vHXBJGRRGXJUNPVSRUDOXIKSUWETGEX |
HUM | 0 |
TEMP | 20 |
BREAKDOWN_VOLTAGE | 0 |
IV_ARRAY | {'time': [0, 2, 4, 6, 8, 10, 12, 14, 16, 18, 20, 22, 24, 26, 28, 30, 32, 34, 36, 38, 40, 42, 44, 46, 48, 50, 52, 54, 56, 58, 60, 62, 64, 66, 68, 70, 72, 74, 76, 78, 80], 'voltage': [0, 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 105, 110, 115, 120, 125, 130, 135, 140, 145, 150, 155, 160, 165, 170, 175, 180, 185, 190, 195, 200], 'current': [1.1e-06, 0.06327999999999999, 0.055689999999999996, 0.05895, 0.061220000000000004, 0.06302, 0.0645, 0.06575, 0.06686, 0.06785000000000001, 0.06871999999999999, 0.06953, 0.07029, 0.071, 0.07168000000000001, 0.07236, 0.07304, 0.07377, 0.07451999999999999, 0.07522, 0.0759, 0.07701, 0.07761, 0.07826999999999999, 0.07898999999999999, 0.07973999999999999, 0.08051, 0.08131000000000001, 0.08214, 0.08302999999999999, 0.08397, 0.08496000000000001, 0.08601, 0.08710000000000001, 0.08825999999999999, 0.08948, 0.09076, 0.0921, 0.09351, 0.09497, 0.0965], 'sigma current': [], 'temperature': [], 'humidity': []} |
IV_IMG | 306d57b7b0e573d43ab8034364f046b16598c2495d8ba55e8da6090b936741bd |
LEAK_CURRENT | 0.07701 |
Test | Local Result | ProdDB Record |
---|---|---|
IV measurement (IV_MEASURE) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
Test | Local Result | ProdDB Record |
---|---|---|
CV measurement (CV_MEASURE) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
IV measurement (IV_MEASURE) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
Test | Local Result | ProdDB Record |
---|---|---|
CV measurement (CV_MEASURE) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
Inter-pixel capacitance (INTER-PIXEL_CAPACITANCE) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
Inter-pixel resistance (INTER-PIXEL_RESISTANCE) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
IT measurement (IT_MEASURE) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
IV measurement (IV_MEASURE) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
Sensor Metrology: Sensor bow and thickness (SENSOR_METROLOGY) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
Test | Local Result | ProdDB Record |
---|---|---|
CV measurement (CV_MEASURE) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
IV measurement (IV_MEASURE) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
Sensor Metrology: Sensor bow and thickness (SENSOR_METROLOGY) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
Visual inspection (VISUAL_INSPECTION) |
No result
Test is missing in LocalDB.
|
N/A
Test is not pushed to ITkPD.
|
Test | Local Result | ProdDB Record |
---|---|---|
CV measurement (CV_MEASURE) |
Registered
Jump to the LocalDB Test Record!
|
Registered
Jump to the ITkPD TestRun Page!
|
IV measurement (IV_MEASURE) |
Registered
Jump to the LocalDB Test Record!
|
Registered
Jump to the ITkPD TestRun Page!
|
LocalDB Test ID | Stage | Test Name | Inspector | Date | QC Registration |
---|---|---|---|---|---|
6436a02dd88aa00038d39fe3 | sensor_manufacturer | IV_MEASURE | ChristopherKrause | 2023-04-12 05:12:29 PDT(-0700) | Selected |
6436a0030ca03e003655a0bb | sensor_manufacturer | CV_MEASURE | ChristopherKrause | 2023-04-12 05:11:47 PDT(-0700) | Selected |
Stage | Tests |
---|---|
sensor_manufacturer |
|
WAFER_PROCESSING |
|
QA |
|
POST_IRRAD |
|
NOT_USED |
|
BAREMODULEASSEMBLY |
|
BAREMODULERECEPTION |
|
MODULE/INIT |
|
MODULE/ASSEMBLY |
|
MODULE/WIREBONDING |
|
MODULE/INITIAL_WARM |
|
MODULE/QC_CROSSCHECK |
|
MODULE/INITIAL_COLD |
|
MODULE/PARYLENE_MASKING |
|
MODULE/PARYLENE_COATING |
|
MODULE/PARYLENE_UNMASKING |
|
MODULE/POST_PARYLENE_WARM |
|
MODULE/POST_PARYLENE_COLD |
|
MODULE/WIREBOND_PROTECTION |
|
MODULE/THERMAL_CYCLES |
|
MODULE/LONG_TERM_STABILITY_TEST |
|
MODULE/FINAL_WARM |
|
MODULE/FINAL_COLD |
|
MODULE/FINAL_METROLOGY |
|
MODULE/QC_STATUS |
|
MODULE/UNHAPPY |
|
MODULE/NOTCONSIDEREDINYIELDS |
|
MODULE/COMPLETE |
|
MODULE/RECEPTION |
|
MODULE/TAB_CUTTING |
|
OB_LOADED_MODULE_CELL/INIT |
|
OB_LOADED_MODULE_CELL/ASSEMBLY |
|
OB_LOADED_MODULE_CELL/THERMAL_CYCLES |
|
OB_LOADED_MODULE_CELL/FINAL_WARM |
|
OB_LOADED_MODULE_CELL/FINAL_COLD |
|
OB_LOADED_MODULE_CELL/THERMAL_COLD |
|
OB_LOADED_MODULE_CELL/THERMAL_WARM |
|
OB_LOADED_MODULE_CELL/ENVELOPE_CHECK |
|
OB_LOADED_MODULE_CELL/QC_STATUS |
|
OB_LOADED_MODULE_CELL/UNHAPPY |
|
OB_LOADED_MODULE_CELL/COMPLETE |
|
OB_LOADED_MODULE_CELL/RECEPTION |
|
OB_LOADED_MODULE_CELL/TAB_CUTTING |
|
OB_LOADED_MODULE_CELL/PIGTAIL_INSERTION |
|