Top Page > Component List > 20UPGS35300177 > QC Result / BAREMODULERECEPTION / IV_MEASURE


20UPGS35300177
Outer-Quad-Sensor
  ITkPD Component Page Jump to ITkPD component page

Component Information

Item Value
Serial Number 20UPGS35300177
Production DB Component ID fc5c8c74faa2ea895724d4167c4dcaf4
LocalDB Component ID 62ba130ee684f9000adaa163
Component Type sensor_tile
Super-Component 20UPGB42000067
Sub-Components No match.
Flags

Properties

Item Data Type Value
Alternative Identifier string V6-1-352913-3-003
Main Vendor integer 5
Sensor Type or Test Structure integer 3
Version of component string pre-production
Scratch id (to be used if not the same as agreed manufacturer ID) string 0012
Original Manufacturer ID string MSLC
Depletion Voltage (V) float 52
Breakdown Voltage (-999 if no breakdown occurred) float None

Comments


Test: IV_MEASURE QC Passed

(Stage: BAREMODULERECEPTION)


Basic View Only: custom view for this TestRun is not prepared.

Metadata

Key Data
QC Passed True
Date 2023-11-14 06:36:08 PST(-0800)
component ObjectId 62ba130ee684f9000adaa163
Stage BAREMODULERECEPTION
Test Type IV_MEASURE
Institute ObjectId
User Name KennethWraight
ObjectId of this record 655385d81525bb00423ae0d8
ObjectId of RAW record None

Results

Key Data
ANALYSIS_VERSION mqat vwebApp
HUM -25.668292682926833
TEMP 22.81463414634146
BREAKDOWN_VOLTAGE -999
IV_ARRAY {'voltage': [0, 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 105, 110, 115, 120, 125, 130, 135, 140, 145, 150, 155, 160, 165, 170, 175, 180, 185, 190, 195, 200], 'current': [1.436079e-08, 1.4373e-07, 1.98113e-07, 2.05047e-07, 2.06288e-07, 2.07211e-07, 2.07834e-07, 2.08513e-07, 2.09338e-07, 2.10041e-07, 2.10736e-07, 2.11916e-07, 2.21368e-07, 2.40875e-07, 2.64211e-07, 2.88852e-07, 3.14398e-07, 3.4055e-07, 3.67463e-07, 3.95138e-07, 4.23435e-07, 4.52507e-07, 4.82229e-07, 5.11456e-07, 5.41778e-07, 5.72905e-07, 6.03541e-07, 6.34553e-07, 6.65699e-07, 6.97711e-07, 7.28435e-07, 7.61063e-07, 7.9354e-07, 8.25665e-07, 8.58039e-07, 8.90887e-07, 9.2352e-07, 9.5667e-07, 9.9011e-07, 1.02224e-06, 1.05719e-06], 'sigma current': [1.436138e-08, 5.47682e-10, 2.111898e-10, 1.443799e-10, 1.445914e-10, 4.45845e-11, 1.458462e-10, 1.28759e-10, 1.321447e-10, 1.360923e-10, 1.694566e-10, 1.429219e-10, 1.435889e-10, 1.34433e-10, 1.40115e-10, 1.17549e-10, 1.209959e-10, 1.333333e-10, 1.512944e-10, 1.326482e-10, 1.633163e-10, 1.389684e-10, 1.575824e-10, 7.167829e-11, 1.633537e-10, 1.543625e-10, 1.086738e-10, 1.473507e-10, 1.497739e-10, 1.454075e-10, 9.96452e-10, 1.320816e-10, 1.895023e-10, 1.896342e-10, 1.587766e-10, 2.067231e-10, 1.47573e-10, 1.888562e-10, 1.72884e-10, 6.669999e-10, 1.285345e-09]}
LEAK_CURRENT 4.23435e-07
MAXIMUM_VOLTAGE 200
NO_BREAKDOWN_VOLTAGE_OBSERVED True

ProductionDB Record

{}

Current Stage: Initial state to associate flex to bare module

No tests are allocated for this stage.


Past QC Stages and Results

  Stage: Bare module reception at ITk institute (BAREMODULERECEPTION) Complete

Test Local Result ProdDB Record
IV measurement
(IV_MEASURE)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!

  Stage: Bare Module Assembly (BAREMODULEASSEMBLY) Complete

No tests are allocated for this stage.

  Stage: Not to be used for detector (NOT_USED) Alternative

No tests are allocated for this stage.

  Stage: Post Irradiation (POST_IRRAD) Alternative

Test Local Result ProdDB Record
CV measurement
(CV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
IV measurement
(IV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.

  Stage: QA at Institutes (QA) Alternative

Test Local Result ProdDB Record
CV measurement
(CV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Inter-pixel capacitance
(INTER-PIXEL_CAPACITANCE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Inter-pixel resistance
(INTER-PIXEL_RESISTANCE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
IT measurement
(IT_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
IV measurement
(IV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Sensor Metrology: Sensor bow and thickness
(SENSOR_METROLOGY)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.

  Stage: Wafer Processing (dicing, UBM, flip-chip) (WAFER_PROCESSING) Locally Signed Off

Test Local Result ProdDB Record
CV measurement
(CV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
IV measurement
(IV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Sensor Metrology: Sensor bow and thickness
(SENSOR_METROLOGY)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Visual inspection
(VISUAL_INSPECTION)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.

  Stage: Sensor Manufacturer (sensor_manufacturer) Complete

Test Local Result ProdDB Record
CV measurement
(CV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
IV measurement
(IV_MEASURE)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
LocalDB Test ID Stage Test Name Inspector Date QC Registration
6634bcc5dda7600035de4634 BAREMODULERECEPTION IV_MEASURE KennethWraight 2024-05-03 03:30:29 PDT(-0700)
655388c51525bb00423ae9b4 BAREMODULERECEPTION IV_MEASURE KennethWraight 2023-11-14 06:48:37 PST(-0800)
655385d81525bb00423ae0d8 BAREMODULERECEPTION IV_MEASURE KennethWraight 2023-11-14 06:36:08 PST(-0800)
655385011525bb00423ade83 BAREMODULERECEPTION IV_MEASURE KennethWraight 2023-11-14 06:32:33 PST(-0800)
655383ae1525bb00423adb16 BAREMODULERECEPTION IV_MEASURE KennethWraight 2023-11-14 06:26:54 PST(-0800)
655381f51525bb00423ad5eb BAREMODULERECEPTION IV_MEASURE KennethWraight 2023-11-14 06:19:33 PST(-0800)
64bead34c8312c0042c56d44 BAREMODULERECEPTION IV_MEASURE RichardBates 2023-07-24 09:56:20 PDT(-0700) Selected
62bc440ae684f9000adf652c sensor_manufacturer IV_MEASURE HanadiAli 2022-06-29 05:22:34 PDT(-0700) Selected
Stage Tests
sensor_manufacturer
  • CV measurement  (CV_MEASURE)
  • IV measurement  (IV_MEASURE)
WAFER_PROCESSING
  • Visual inspection  (VISUAL_INSPECTION)
  • Sensor Metrology: Sensor bow and thickness  (SENSOR_METROLOGY)
  • IV measurement  (IV_MEASURE)
  • CV measurement  (CV_MEASURE)
QA
  • CV measurement  (CV_MEASURE)
  • IV measurement  (IV_MEASURE)
  • IT measurement  (IT_MEASURE)
  • Inter-pixel capacitance  (INTER-PIXEL_CAPACITANCE)
  • Inter-pixel resistance  (INTER-PIXEL_RESISTANCE)
  • Sensor Metrology: Sensor bow and thickness  (SENSOR_METROLOGY)
POST_IRRAD
  • IV measurement  (IV_MEASURE)
  • CV measurement  (CV_MEASURE)
NOT_USED
BAREMODULEASSEMBLY
BAREMODULERECEPTION
  • IV measurement  (IV_MEASURE)
MODULE/INIT
MODULE/ASSEMBLY
MODULE/WIREBONDING
MODULE/INITIAL_WARM
MODULE/QC_CROSSCHECK
MODULE/INITIAL_COLD
MODULE/PARYLENE_MASKING
MODULE/PARYLENE_COATING
MODULE/PARYLENE_UNMASKING
MODULE/POST_PARYLENE_WARM
MODULE/POST_PARYLENE_COLD
MODULE/WIREBOND_PROTECTION
MODULE/THERMAL_CYCLES
MODULE/LONG_TERM_STABILITY_TEST
MODULE/FINAL_WARM
MODULE/FINAL_COLD
MODULE/FINAL_METROLOGY
MODULE/QC_STATUS
MODULE/UNHAPPY
MODULE/NOTCONSIDEREDINYIELDS
MODULE/COMPLETE
MODULE/RECEPTION
MODULE/TAB_CUTTING
OB_LOADED_MODULE_CELL/INIT
OB_LOADED_MODULE_CELL/ASSEMBLY
OB_LOADED_MODULE_CELL/THERMAL_CYCLES
OB_LOADED_MODULE_CELL/FINAL_WARM
OB_LOADED_MODULE_CELL/FINAL_COLD
OB_LOADED_MODULE_CELL/THERMAL_COLD
OB_LOADED_MODULE_CELL/THERMAL_WARM
OB_LOADED_MODULE_CELL/ENVELOPE_CHECK
OB_LOADED_MODULE_CELL/QC_STATUS
OB_LOADED_MODULE_CELL/UNHAPPY
OB_LOADED_MODULE_CELL/COMPLETE
OB_LOADED_MODULE_CELL/RECEPTION
OB_LOADED_MODULE_CELL/TAB_CUTTING
OB_LOADED_MODULE_CELL/PIGTAIL_INSERTION
Back to top page of this component