Top Page > Component List > 20UPGS35300175 > QC Result / BAREMODULERECEPTION / IV_MEASURE


20UPGS35300175
Outer-Quad-Sensor
  ITkPD Component Page Jump to ITkPD component page

Component Information

Item Value
Serial Number 20UPGS35300175
Production DB Component ID a45bea33473cba4fdabc98cebb7a7bdc
LocalDB Component ID 62ba12f2e684f9000adaa11e
Component Type sensor_tile
Super-Component 20UPGB42000066
Sub-Components No match.
Flags

Properties

Item Data Type Value
Alternative Identifier string V6-1-352913-3-002
Main Vendor integer 5
Sensor Type or Test Structure integer 3
Version of component string pre-production
Scratch id (to be used if not the same as agreed manufacturer ID) string 0012
Original Manufacturer ID string MSLB
Depletion Voltage (V) float 52
Breakdown Voltage (-999 if no breakdown occurred) float None

Comments


Test: IV_MEASURE QC Passed

(Stage: BAREMODULERECEPTION)


Basic View Only: custom view for this TestRun is not prepared.

Metadata

Key Data
QC Passed True
Date 2023-11-09 03:12:52 PST(-0800)
component ObjectId 62ba12f2e684f9000adaa11e
Stage BAREMODULERECEPTION
Test Type IV_MEASURE
Institute ObjectId
User Name KennethWraight
ObjectId of this record 654cbeb45bcdfc0042805b2b
ObjectId of RAW record None

Results

Key Data
ANALYSIS_VERSION mqat vwebApp
HUM 46.2
TEMP 21
BREAKDOWN_VOLTAGE 150
IV_ARRAY {'voltage': [0, 5, 10, 15, 20, 25, 30, 35, 40, 45, 50, 55, 60, 65, 70, 75, 80, 85, 90, 95, 100, 105, 110, 115, 120, 125, 130, 135, 140, 145, 150, 155, 160, 165, 170, 175, 180, 185, 190, 195, 200], 'current': [0.0014792359999999999, 0.16389117, 0.18609288000000002, 0.19128981, 0.19360665, 0.19532122999999998, 0.19734646, 0.20045408, 0.20444118, 0.20763296, 0.21004613, 0.21148597, 0.21305194, 0.21442073, 0.21578815, 0.21678086000000002, 0.21790868, 0.21939606, 0.22069426, 0.22224929999999998, 0.22363305, 0.22524138, 0.22735121, 0.22924513000000002, 0.23195976, 0.23521495, 0.23958869, 0.24665648, 0.25984046, 0.29480827, 0.40563579, 0.7062038900000001, 1.2337329000000001, 1.9323594, 2.801058, 3.8329637000000005, 4.947175400000001, 6.0856859000000005, 7.1982263, 8.2821548, 9.360711499999999], 'sigma current': [0.00016337362319202234, 0.0005660026993457385, 0.00030313004470028837, 0.00015263876346168027, 0.0013088704513179786, 0.0009678422381198763, 0.00112994279914221, 0.0010372017298695788, 0.0010001589082629734, 0.0011316836672262513, 0.001114506098931521, 0.0011129555866650224, 0.0011131743121961352, 0.0011481202773325667, 0.0011184614385147305, 0.0010249257037572156, 0.0011396529177292928, 0.0011241825822446386, 0.0011031414397075232, 0.0010024365859688552, 0.0011036104649437422, 0.0011326770401722328, 0.001098584531163217, 0.0011127811106013197, 0.0011344759026871271, 0.0011860827001801673, 0.0009164068764594789, 0.0011759405170141731, 0.0012859418262287207, 0.0017004268457916306, 0.0045326809119867395, 0.010618565189060762, 0.01598447478336399, 0.020002058839584988, 0.02354142262764373, 0.027488027337369995, 0.028884686481863653, 0.02916555310807584, 0.024583255647560903, 0.024761877503757985, 0.027593260639551642], 'temperature': [21, 21, 21, 21, 21, 21, 21, 21, 21, 21, 21, 21, 21, 21, 21, 21, 21, 21, 21, 21, 21, 21, 21, 21, 21, 21, 21, 21, 21, 21, 21, 21, 21, 21, 21, 21, 21, 21, 21, 21, 21], 'humidity': [46.2, 46.2, 46.2, 46.2, 46.2, 46.2, 46.2, 46.2, 46.2, 46.2, 46.2, 46.2, 46.2, 46.2, 46.2, 46.2, 46.2, 46.2, 46.2, 46.2, 46.2, 46.2, 46.2, 46.2, 46.2, 46.2, 46.2, 46.2, 46.2, 46.2, 46.2, 46.2, 46.2, 46.2, 46.2, 46.2, 46.2, 46.2, 46.2, 46.2, 46.2]}
LEAK_CURRENT 0.22363305
MAXIMUM_VOLTAGE 200
NO_BREAKDOWN_VOLTAGE_OBSERVED False

ProductionDB Record

{}

Current Stage: Final flatness measurement

No tests are allocated for this stage.


Past QC Stages and Results

  Stage: Final Cold (MODULE/FINAL_COLD) Complete

No tests are allocated for this stage.

  Stage: Final Warm (MODULE/FINAL_WARM) Complete

No tests are allocated for this stage.

  Stage: Long Term Stability Test (MODULE/LONG_TERM_STABILITY_TEST) Complete

No tests are allocated for this stage.

  Stage: Thermal Cycles (MODULE/THERMAL_CYCLES) Complete

No tests are allocated for this stage.

  Stage: Wirebond Protection (alt) (MODULE/WIREBOND_PROTECTION) Alternative

No tests are allocated for this stage.

  Stage: Post-Parylene Cold (MODULE/POST_PARYLENE_COLD) Complete

No tests are allocated for this stage.

  Stage: Post-Parylene Warm (MODULE/POST_PARYLENE_WARM) Complete

No tests are allocated for this stage.

  Stage: Parylene Unmasking (MODULE/PARYLENE_UNMASKING) Complete

No tests are allocated for this stage.

  Stage: Parylene Coating (MODULE/PARYLENE_COATING) Complete

No tests are allocated for this stage.

  Stage: Parylene Masking (MODULE/PARYLENE_MASKING) Complete

No tests are allocated for this stage.

  Stage: Initial Cold (MODULE/INITIAL_COLD) Complete

No tests are allocated for this stage.

  Stage: QC cross-check (module swapping) (MODULE/QC_CROSSCHECK) Complete

No tests are allocated for this stage.

  Stage: Initial Warm (MODULE/INITIAL_WARM) Complete

No tests are allocated for this stage.

  Stage: Wire Bonding (MODULE/WIREBONDING) Complete

No tests are allocated for this stage.

  Stage: Bare module to module PCB assembly (MODULE/ASSEMBLY) Complete

No tests are allocated for this stage.

  Stage: Initial state to associate flex to bare module (MODULE/INIT) Complete

No tests are allocated for this stage.

  Stage: Bare module reception at ITk institute (BAREMODULERECEPTION) Complete

Test Local Result ProdDB Record
IV measurement
(IV_MEASURE)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!

  Stage: Bare Module Assembly (BAREMODULEASSEMBLY) Locally Signed Off

No tests are allocated for this stage.

  Stage: Not to be used for detector (NOT_USED) Alternative

No tests are allocated for this stage.

  Stage: Post Irradiation (POST_IRRAD) Alternative

Test Local Result ProdDB Record
CV measurement
(CV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
IV measurement
(IV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.

  Stage: QA at Institutes (QA) Alternative

Test Local Result ProdDB Record
CV measurement
(CV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Inter-pixel capacitance
(INTER-PIXEL_CAPACITANCE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Inter-pixel resistance
(INTER-PIXEL_RESISTANCE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
IT measurement
(IT_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
IV measurement
(IV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Sensor Metrology: Sensor bow and thickness
(SENSOR_METROLOGY)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.

  Stage: Wafer Processing (dicing, UBM, flip-chip) (WAFER_PROCESSING) Locally Signed Off

Test Local Result ProdDB Record
CV measurement
(CV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
IV measurement
(IV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Sensor Metrology: Sensor bow and thickness
(SENSOR_METROLOGY)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
Visual inspection
(VISUAL_INSPECTION)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.

  Stage: Sensor Manufacturer (sensor_manufacturer) Complete

Test Local Result ProdDB Record
CV measurement
(CV_MEASURE)
No result Test is missing in LocalDB.
N/A Test is not pushed to ITkPD.
IV measurement
(IV_MEASURE)
Registered Jump to the LocalDB Test Record!
Registered Jump to the ITkPD TestRun Page!
LocalDB Test ID Stage Test Name Inspector Date QC Registration
654ce70cb60c210041df0e74 BAREMODULERECEPTION IV_MEASURE KennethWraight 2023-11-09 06:05:00 PST(-0800)
654cbeb45bcdfc0042805b2b BAREMODULERECEPTION IV_MEASURE KennethWraight 2023-11-09 03:12:52 PST(-0800)
654cb63ab60c210041de521f BAREMODULERECEPTION IV_MEASURE KennethWraight 2023-11-09 02:36:42 PST(-0800)
64beac75c8312c0042c54639 BAREMODULERECEPTION IV_MEASURE RichardBates 2023-07-24 09:53:09 PDT(-0700) Selected
62bc4405e684f9000adf650a sensor_manufacturer IV_MEASURE HanadiAli 2022-06-29 05:22:29 PDT(-0700) Selected
Stage Tests
sensor_manufacturer
  • CV measurement  (CV_MEASURE)
  • IV measurement  (IV_MEASURE)
WAFER_PROCESSING
  • Visual inspection  (VISUAL_INSPECTION)
  • Sensor Metrology: Sensor bow and thickness  (SENSOR_METROLOGY)
  • IV measurement  (IV_MEASURE)
  • CV measurement  (CV_MEASURE)
QA
  • CV measurement  (CV_MEASURE)
  • IV measurement  (IV_MEASURE)
  • IT measurement  (IT_MEASURE)
  • Inter-pixel capacitance  (INTER-PIXEL_CAPACITANCE)
  • Inter-pixel resistance  (INTER-PIXEL_RESISTANCE)
  • Sensor Metrology: Sensor bow and thickness  (SENSOR_METROLOGY)
POST_IRRAD
  • IV measurement  (IV_MEASURE)
  • CV measurement  (CV_MEASURE)
NOT_USED
BAREMODULEASSEMBLY
BAREMODULERECEPTION
  • IV measurement  (IV_MEASURE)
MODULE/INIT
MODULE/ASSEMBLY
MODULE/WIREBONDING
MODULE/INITIAL_WARM
MODULE/QC_CROSSCHECK
MODULE/INITIAL_COLD
MODULE/PARYLENE_MASKING
MODULE/PARYLENE_COATING
MODULE/PARYLENE_UNMASKING
MODULE/POST_PARYLENE_WARM
MODULE/POST_PARYLENE_COLD
MODULE/WIREBOND_PROTECTION
MODULE/THERMAL_CYCLES
MODULE/LONG_TERM_STABILITY_TEST
MODULE/FINAL_WARM
MODULE/FINAL_COLD
MODULE/FINAL_METROLOGY
MODULE/QC_STATUS
MODULE/UNHAPPY
MODULE/NOTCONSIDEREDINYIELDS
MODULE/COMPLETE
MODULE/RECEPTION
MODULE/TAB_CUTTING
OB_LOADED_MODULE_CELL/INIT
OB_LOADED_MODULE_CELL/ASSEMBLY
OB_LOADED_MODULE_CELL/THERMAL_CYCLES
OB_LOADED_MODULE_CELL/FINAL_WARM
OB_LOADED_MODULE_CELL/FINAL_COLD
OB_LOADED_MODULE_CELL/THERMAL_COLD
OB_LOADED_MODULE_CELL/THERMAL_WARM
OB_LOADED_MODULE_CELL/ENVELOPE_CHECK
OB_LOADED_MODULE_CELL/QC_STATUS
OB_LOADED_MODULE_CELL/UNHAPPY
OB_LOADED_MODULE_CELL/COMPLETE
OB_LOADED_MODULE_CELL/RECEPTION
OB_LOADED_MODULE_CELL/TAB_CUTTING
OB_LOADED_MODULE_CELL/PIGTAIL_INSERTION
Back to top page of this component